{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,19]],"date-time":"2026-07-19T14:39:44Z","timestamp":1784471984363,"version":"3.55.0"},"reference-count":35,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2019,11,27]],"date-time":"2019-11-27T00:00:00Z","timestamp":1574812800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2020,4]]},"abstract":"<jats:p>In this study, we present the design considerations of a device to assist in the potential treatment of hemorrhagic stroke with the aim of stopping blood from flowing out into brain tissue. We present and model three designs for the clinical scenarios when saccular aneurysms rupture in the middle cerebral artery in the brain. We evaluate and model these three designs using computer aided design software, SolidWorks, which allows the devices to be tested using finite element analysis and also enables us to justify that the materials chosen were suitable for potential use. Computational fluid dynamics modelling were used to demonstrate and analyse the flow of blood through the artery under conditions of normal and ruptured states. We conclude that our device could potentially be useful in the treatment of hemorrhagic stroke, and the modelling process is useful in assisting in determining the performance of our devices.<\/jats:p>","DOI":"10.1177\/0954411919890698","type":"journal-article","created":{"date-parts":[[2019,11,27]],"date-time":"2019-11-27T10:17:03Z","timestamp":1574849823000},"page":"323-336","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":6,"title":["An investigation into the design of a device to treat haemorrhagic stroke"],"prefix":"10.1177","volume":"234","author":[{"given":"Hardeep Singh","family":"Randhawa","sequence":"first","affiliation":[{"name":"School of Engineering and Applied Science, Aston University, Birmingham, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gillian","family":"Pearce","sequence":"additional","affiliation":[{"name":"School of Engineering and Applied Science, Aston University, Birmingham, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel","family":"Hepton","sequence":"additional","affiliation":[{"name":"The School of Life & Health Sciences, Aston University, Birmingham, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Wong","sequence":"additional","affiliation":[{"name":"Department of Cardiac, Thoracic and Vascular Surgery, National University Heart Centre, Singapore"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8105-7954","authenticated-orcid":false,"given":"Iham F","family":"Zidane","sequence":"additional","affiliation":[{"name":"Mechanical Engineering Department, College of Engineering and Technology, Arab Academy for Science, Technology and Maritime Transport (AASTMT), Alexandria, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4957-2942","authenticated-orcid":false,"given":"Xianghong","family":"Ma","sequence":"additional","affiliation":[{"name":"School of Engineering and Applied Science, Aston University, Birmingham, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2019,11,27]]},"reference":[{"key":"bibr1-0954411919890698","unstructured":"Stroke Association. State of the Nation: stroke statistics, 2018, https:\/\/www.stroke.org.uk\/resources\/state-nation-stroke-statistics"},{"key":"bibr2-0954411919890698","unstructured":"British Heart Foundation. CVD statistics \u2013 BHF UK factsheet, 2018, https:\/\/fdocuments.in\/document\/cvd-statistics-bhf-uk-factsheet-statistics-bhf-uk-factsheet-last-reviewed.html"},{"key":"bibr3-0954411919890698","unstructured":"Royal College of Physicians London. Stroke guidelines (Intercollegiate Stroke Working Party, National Institute for Health and Care Excellence (NICE)), 2016, https:\/\/www.rcplondon.ac.uk\/guidelines-policy\/stroke-guidelines"},{"key":"bibr4-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.113.002390"},{"issue":"12","key":"bibr5-0954411919890698","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.accreview.2005.11.083","volume":"14","author":"Molyneux A","year":"2005","journal-title":"ACC Curr J Rev"},{"key":"bibr6-0954411919890698","doi-asserted-by":"publisher","DOI":"10.3340\/jkns.2009.45.3.133"},{"key":"bibr7-0954411919890698","unstructured":"Facts and Figures about Stroke, World Stroke Organization, https:\/\/www.world-stroke.org\/component\/content\/article\/16-forpatients\/84-facts-and-figures-about-stroke (accessed 18 November 2019)."},{"key":"bibr8-0954411919890698","doi-asserted-by":"publisher","DOI":"10.3171\/2015.10.JNS151586"},{"key":"bibr9-0954411919890698","unstructured":"NHS. Treatment, 2018, https:\/\/www.nhs.uk\/conditions\/stroke\/treatment\/"},{"key":"bibr10-0954411919890698","unstructured":"Friedlander R. Guglielmi detachable coils (GDC) Neurosurgery University of Pittsburgh (Neurosurgery.pitt.edu), 2018, http:\/\/www.neurosurgery.pitt.edu\/centers-excellence\/cerebrovascular-neurosurgery-center\/neuroendovascular-therapy\/treatments\/gdc"},{"key":"bibr11-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.0000130855.70683.c8"},{"key":"bibr12-0954411919890698","unstructured":"World Stroke Campaign. Learn about stroke: types of stroke, ischemic stroke, hemorrhagic stroke, 2018, https:\/\/www.worldstrokecampaign.org\/world-stroke-day-campaign\/why-stroke-matters\/learn-about-stroke\/types-of-stroke"},{"key":"bibr13-0954411919890698","unstructured":"Ringer A. Intracerebral hemorrhage (ICH), hemorrhagic stroke, stroke Cincinnati, OH Mayfield Brain & Spine. Mayfieldclinic.com, 2018, http:\/\/www.mayfieldclinic.com\/PE-ICH.HTM"},{"key":"bibr14-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1161\/STR.0000000000000069"},{"key":"bibr15-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(11)70264-2"},{"key":"bibr16-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1016\/S0377-1237(03)80147-8"},{"key":"bibr17-0954411919890698","unstructured":"NHS. Treatment, 2017, https:\/\/www.nhs.uk\/conditions\/hydrocephalus\/treatment\/"},{"key":"bibr18-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0107614"},{"key":"bibr19-0954411919890698","first-page":"8584753","volume":"2017","author":"Chen S","year":"2017","journal-title":"Biomed Res Int"},{"key":"bibr20-0954411919890698","unstructured":"NHS. Subarachnoid haemorrhage, 2016, https:\/\/www.nhs.uk\/conditions\/subarachnoid-haemorrhage\/"},{"key":"bibr21-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e3182804aa2"},{"key":"bibr22-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.111.000641"},{"key":"bibr23-0954411919890698","doi-asserted-by":"crossref","unstructured":"Wolstenholme J, Rivero-Arias O, Gray A, et al. Treatment pathways, resource use, and costs of endovascular coiling versus surgical clipping after aSAH. Stroke 2008; 39(1): 111\u2013119, http:\/\/stroke.ahajournals.org\/content\/39\/1\/111.long","DOI":"10.1161\/STROKEAHA.107.482570"},{"key":"bibr24-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1177\/1971400915602803"},{"key":"bibr25-0954411919890698","volume-title":"Development of bioabsorbable braided vascular scaffolds for the intracranial circulation","author":"Jamshidi M.","year":"2019"},{"key":"bibr26-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.31.10.2369"},{"key":"bibr27-0954411919890698","unstructured":"ABDOPAIN.com. Abdominal aortic aneurysm causes, diagnosis, treatment options & prevention, 2018, https:\/\/www.abdopain.com\/abdominal-aortic-aneurysm.html"},{"key":"bibr28-0954411919890698","doi-asserted-by":"publisher","DOI":"10.3109\/13645700009169654"},{"key":"bibr29-0954411919890698","doi-asserted-by":"publisher","DOI":"10.3390\/ijms12074250"},{"key":"bibr30-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-003-2022-5"},{"key":"bibr31-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-#"},{"key":"bibr32-0954411919890698","unstructured":"ANSYS\u00ae Mechanical Enterprise, Release 15.0, ANSYS, Inc."},{"key":"bibr33-0954411919890698","doi-asserted-by":"publisher","DOI":"10.1016\/j.asej.2014.05.010"},{"key":"bibr34-0954411919890698","volume-title":"Proceedings of the fifth international conference on CFD in the process industries","author":"Sinnott M"},{"key":"bibr35-0954411919890698","doi-asserted-by":"publisher","DOI":"10.3390\/ijms12074250"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411919890698","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0954411919890698","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411919890698","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:25:23Z","timestamp":1777674323000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0954411919890698"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,27]]},"references-count":35,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["10.1177\/0954411919890698"],"URL":"https:\/\/doi.org\/10.1177\/0954411919890698","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,27]]}}}