{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T09:04:32Z","timestamp":1792141472414,"version":"4.4.0"},"reference-count":54,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2020,6,3]],"date-time":"2020-06-03T00:00:00Z","timestamp":1591142400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:p>\n                    Efficacy and outcomes of osteosynthesis depend on various factors including types of injury and repair, host factors, characteristics of implant materials and type of implantation. One of the most important host factors appears to be the extent of bone damage due to the mechanical force and thermal injury which are produced at cutting site during bone drilling. The temperature above the critical temperature (47 \u00b0C) produces thermal osteonecrosis in the bones. In the present work, experimental investigations were performed to determine the effect of drilling parameters (rotational speed, feed rate and drill diameter) and techniques (conventional surgical bone drilling and rotary ultrasonic bone drilling) on cutting force and temperature generated during bone drilling. The drilling experiments were performed by a newly developed bone drilling machine on different types of human bones (femur, tibia and fibula) having different biological structure and mechanical behaviour. The bone samples were procured from male cadavers with the age of second to fourth decades. The results revealed that there was a significant difference (\n                    <jats:italic toggle=\"yes\">p<\/jats:italic>\n                    \u2009&lt;\u20090.05) in cutting force and temperature rise for rotary ultrasonic bone drilling and conventional surgical bone drilling. The cutting force obtained in rotary ultrasonic bone drilling was 30%\u201340%, whereas temperature generated was 50%\u201355% lesser than conventional surgical bone drilling process for drilling in all types of bones. It was also found that the cutting force increased with increasing feed rate, drill diameter and decrease in rotational speed, whereas increasing rotational speed, drill diameter and feed rate resulted in higher heat generation during bone drilling. Both the techniques revealed that the axial cutting force and the temperature rise were significantly higher in femur and tibia compared with the fibula for all combinations of process parameters.\n                  <\/jats:p>","DOI":"10.1177\/0954411920925254","type":"journal-article","created":{"date-parts":[[2020,6,3]],"date-time":"2020-06-03T09:20:43Z","timestamp":1591176043000},"page":"829-842","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":31,"title":["Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones"],"prefix":"10.1177","volume":"234","author":[{"given":"Ravinder Pal","family":"Singh","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5048-8388","authenticated-orcid":false,"given":"Pulak Mohan","family":"Pandey","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Indian Institute of Technology Delhi, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chittaranjan","family":"Behera","sequence":"additional","affiliation":[{"name":"Department of Forensic Medicine, All India Institute of Medical Sciences (AIIMS), New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7978-428X","authenticated-orcid":false,"given":"Asit Ranjan","family":"Mridha","sequence":"additional","affiliation":[{"name":"Department of Pathology, All India Institute of Medical Sciences (AIIMS), New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2020,6,3]]},"reference":[{"key":"e_1_3_2_2_2","first-page":"5","article-title":"Implant failure in osteosynthesis of fractures of long bones","volume":"5","author":"Ogbemudia AO","year":"2006","unstructured":"Ogbemudia AO, Umebese PFA. Implant failure in osteosynthesis of fractures of long bones. J Med Biomed Res 2006; 5: 5\u20138.","journal-title":"J Med Biomed Res"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1080\/000164701317323381"},{"key":"e_1_3_2_4_2","first-page":"657","article-title":"Evaluation of delamination in drilling of bone","volume":"37","author":"Pandey RK","year":"2015","unstructured":"Pandey RK, Panda SS. Evaluation of delamination in drilling of bone. Measurement 2015; 37: 657\u2013664.","journal-title":"Measurement"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4001883"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318156c288"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(01)00016-9"},{"key":"e_1_3_2_8_2","first-page":"1","article-title":"Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury","volume":"9","author":"Lundskog J.","year":"1971","unstructured":"Lundskog J. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury. Scand J Plast Reconstr Surg 1971; 9: 1\u201380.","journal-title":"Scand J Plast Reconstr Surg"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1080\/10910344.2013.837353"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4007953"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2012.12.004"},{"key":"e_1_3_2_12_2","first-page":"103","article-title":"Investigation into bone drilling and thermal bone necrosis","volume":"2","author":"Udiljak T","year":"2007","unstructured":"Udiljak T, Ciglar D, Skoric S. Investigation into bone drilling and thermal bone necrosis. J Med Biomed Res 2007; 2: 103\u2013112.","journal-title":"J Med Biomed Res"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjoms.2012.10.023"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-012-1491-z"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411915573064"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2010.10.003"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/845205"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2016.11.004"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-014-5998-x"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2020.01.007"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-007-0427-3"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjoms.2012.02.003"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.5099\/aj090400312"},{"key":"e_1_3_2_24_2","first-page":"261","article-title":"Experimental analysis of drilling process in cortical bone","volume":"36","author":"Yuan A","year":"2016","unstructured":"Yuan A, Wang W, Shi Y, et al. Experimental analysis of drilling process in cortical bone. Med Eng Phys 2016; 36: 261\u2013266.","journal-title":"Med Eng Phys"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmapro.2020.01.024"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-018-2718-y"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2019.103599"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2018.12.019"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954405416673115"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411919898301"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2016.08.012"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2020.03.002"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411916688500"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0924-0136(99)00155-7"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.2174\/1874088X01509010178"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1556-4029.2006.00368.x"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(93)90051-3"},{"key":"e_1_3_2_38_2","first-page":"213","volume-title":"Biomedical engineering IV Proceedings of the Fourth Southern Biomedical Engineering Conference: 1985","author":"Ucisik AH","unstructured":"Ucisik AH, Goksan MA, Ucok I. Comparative mechanical properties of human bones. In: Biomedical engineering IV Proceedings of the Fourth Southern Biomedical Engineering Conference: 1985 (ed Sauer Barry W.), pp.213\u2013216. Pergamon Press (Elsevier)."},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1002\/aja.1001200107"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411919889913"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2010.08.012"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1080\/13102818.2015.1034176"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-020-02452-w"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultras.2013.09.005"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.3923\/ajsr.2008.12.21"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2013.04.022"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2011.05.014"},{"key":"e_1_3_2_48_2","doi-asserted-by":"publisher","DOI":"10.1243\/PIME_PROC_1963_177_058_02"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4026625"},{"key":"e_1_3_2_50_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-015-7259-z"},{"key":"e_1_3_2_51_2","doi-asserted-by":"publisher","DOI":"10.3233\/THC-140813"},{"key":"e_1_3_2_52_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2012.03.002"},{"key":"e_1_3_2_53_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2011.05.013"},{"key":"e_1_3_2_54_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ceramint.2019.04.226"},{"key":"e_1_3_2_55_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-019-03367-0"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411920925254","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0954411920925254","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0954411920925254","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:25:43Z","timestamp":1777674343000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0954411920925254"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,3]]},"references-count":54,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2020,8]]}},"alternative-id":["10.1177\/0954411920925254"],"URL":"https:\/\/doi.org\/10.1177\/0954411920925254","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,3]]}}}