{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T20:34:32Z","timestamp":1777926872219,"version":"3.51.4"},"reference-count":32,"publisher":"SAGE Publications","issue":"12","license":[{"start":{"date-parts":[[2021,8,18]],"date-time":"2021-08-18T00:00:00Z","timestamp":1629244800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:p>Stability plays a vital role in any robotic system. Its significance increases in systems related to health and medicine. For rehabilitation devices meant for Spinal Cord Injury (SCI) patients, stability is crucial and key element in ensuring patient safety and the usefulness of the devices. In this study, kinematics, force analysis, and the static tip-over stability of a device for rehabilitation of paraplegic patients is discussed. Kinematics modeling and static force analysis provide critical information about position and loading at different points on the device. Force-Angle Stability Criterion is used to find the static tip-over stability of the device while the patient is on board the device. The Criterion relies on the support boundary, tip-over mode axes, and the Center of Mass (COM) of the complete system. The Criterion is sensitive to the COM position and therefore is more suitable for the application. The linear actuator mounted on the device causes the end effector of the device to move. The patient, strapped with the end effector, in turn moves from sitting position to standing position. The study focuses on the analysis of stability based on changing COM during this motion. The results verify that although the system is well within the stability bounds, it is more stable as it moves from sitting position to standing position.<\/jats:p>","DOI":"10.1177\/09544119211036954","type":"journal-article","created":{"date-parts":[[2021,8,18]],"date-time":"2021-08-18T06:41:13Z","timestamp":1629268873000},"page":"1399-1412","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Static force and tipover stability analysis of an assistive device for paraplegics"],"prefix":"10.1177","volume":"235","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4736-3955","authenticated-orcid":false,"given":"Ahmad","family":"Abdullah","sequence":"first","affiliation":[{"name":"Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Paksitan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zareena","family":"Kausar","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Paksitan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haroon","family":"Raza","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Paksitan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdullah","family":"Siddiqui","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Paksitan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neelum","family":"Yousaf","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Paksitan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zahid","family":"Hussain","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Biomedical Engineering, Air University, Islamabad, Paksitan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2021,8,18]]},"reference":[{"key":"bibr1-09544119211036954","first-page":"753165","volume":"2012","author":"Sonenblum SE","year":"2012","journal-title":"Rehabil Res Pract"},{"key":"bibr2-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/MPUL.2012.2196836"},{"key":"bibr3-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/ARSO.2016.7736252"},{"key":"bibr4-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-11-169"},{"key":"bibr5-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/ACC.2007.4282620"},{"key":"bibr6-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2008.922668"},{"key":"bibr7-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2015.09.007"},{"key":"bibr8-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2016.2514357"},{"key":"bibr9-09544119211036954","first-page":"234","volume-title":"2012 IEEE RO-MAN: the 21st IEEE international symposium on robot and human interactive communication","author":"Chugo D"},{"key":"bibr10-09544119211036954","first-page":"1","volume-title":"2012 12th IEEE international workshop on advanced motion control (AMC)","author":"Chugo D"},{"key":"bibr11-09544119211036954","first-page":"470","volume-title":"2014 14th International conference on control, automation and systems (ICCAS 2014)","author":"Takahara S"},{"key":"bibr12-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.2018.8594199"},{"key":"bibr13-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2018.2799865"},{"key":"bibr14-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1115\/1.4037287"},{"key":"bibr15-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1080\/01691864.2014.992956"},{"key":"bibr16-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.11.037"},{"key":"bibr17-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1007\/s10514-015-9438-z"},{"key":"bibr18-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1177\/1687814017703894"},{"key":"bibr19-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1108\/01439911111106354"},{"key":"bibr20-09544119211036954","volume-title":"Modeling of a device for independent mobility of paraplegic patients","author":"Maryam K.","year":"2016"},{"key":"bibr21-09544119211036954","doi-asserted-by":"crossref","unstructured":"Khan M, Kausar Z. Kinematics modeling and mechanism configuration selection of a mechatronic assistive device for paraplegic patients. In Proceedings of the 5th international conference on mechatronics and control engineering. 2016. Venice, Italy, pp.27\u201332. Association for Computing Machinery, New York, NY, United States, DOI: http:\/\/dx.doi.org\/10.1145\/3036932.3036941.","DOI":"10.1145\/3036932.3036941"},{"key":"bibr22-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1016\/1\/012005"},{"key":"bibr23-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2020.110046"},{"key":"bibr24-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2018.02.022"},{"key":"bibr25-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.02.018"},{"key":"bibr26-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.1993.583186"},{"key":"bibr27-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1115\/1.4035234"},{"key":"bibr28-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/j.robot.2018.09.005"},{"key":"bibr29-09544119211036954","volume-title":"Proceedings of the 18th international symposium on dynamic problems of mechanics (DINAME)","author":"Medeiros V","year":"2019"},{"key":"bibr30-09544119211036954","volume-title":"ASME international mechanical engineering congress and exposition","volume":"59414","author":"Nazem Tahmasebi K"},{"key":"bibr31-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1076\/0042-3114(200001)33:1;1-5;FT029"},{"key":"bibr32-09544119211036954","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(95)00178-6"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119211036954","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119211036954","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119211036954","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:26:41Z","timestamp":1777674401000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119211036954"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,18]]},"references-count":32,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["10.1177\/09544119211036954"],"URL":"https:\/\/doi.org\/10.1177\/09544119211036954","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,18]]}}}