{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T23:24:44Z","timestamp":1794439484949,"version":"4.9.1"},"reference-count":38,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2023,12,16]],"date-time":"2023-12-16T00:00:00Z","timestamp":1702684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:p>In recent years, artificial cervical discs have been used in intervertebral disc replacement surgery and hybrid surgery (HS). The advantages and disadvantages of different artificial cervical discs in artificial cervical disc replacement surgery have been compared. However, few scholars have studied the biomechanical effects of various artificial disc prostheses on the human cervical spine in HS which include the Anterior Cervical Discectomy and Fusion (ACDF) and Cervical Disc Arthroplasty (CDA). This study compared the biomechanical behavior of Mobi-C and Prestige LP in the operative and adjacent segments during two-level hybrid surgery. A three-dimensional finite element model of C2\u2013C7 was first established and validated. Subsequently, clinical surgery was then simulated to establish a surgical model of anterior cervical fusion at the C4\u2013C5 level. Mobi-C and Prestige-LP artificial disc prostheses were implanted at the C5\u2013C6 level to create two hybrid models. All finite element models were fixed on the lower endplate of the C7 vertebra and subjected to a load of 73.6\u2009N and different directions of 1\u2009Nm torque on the odontoid process of the C2 vertebra to simulate human flexion, extension, lateral bending, and axial rotation. This paper compares the ROM, intervertebral pressure, and facet joint force after hybrid surgery with the intact model. The results show that compared with Prestige LP, Mobi-C can improve ROM of the replacement segment and compensate for the intervertebral pressure of the adjacent segment more effectively, but the facet joint pressure of the replacement segment may be higher.<\/jats:p>","DOI":"10.1177\/09544119231215721","type":"journal-article","created":{"date-parts":[[2023,12,16]],"date-time":"2023-12-16T05:22:41Z","timestamp":1702704161000},"page":"78-89","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":6,"title":["Comparison of the effects of different artificial discs on hybrid surgery: A finite element analysis"],"prefix":"10.1177","volume":"238","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2932-057X","authenticated-orcid":false,"given":"Wei","family":"Jiang","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, Dalian University of Technology, Dalian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fulin","family":"Zhao","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Dalian University of Technology, Dalian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waseem Ur","family":"Rahman","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Dalian University of Technology, Dalian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianxiang","family":"Dong","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Dalian University of Technology, Dalian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guanghui","family":"Yang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Dalian University of Technology, Dalian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2023,12,16]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/WNQ.0b013e3181ce0d13"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181df10fc"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-008-0854-z"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-017-9398-3"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e31815d0034"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e31822699fa"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.2147\/TCRM.S196349"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-010-1583-7"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-007-0459-y"},{"issue":"2","key":"e_1_3_2_11_2","first-page":"111","article-title":"Segmental malalignment with the Bryan cervical disc prosthesis\u2014contributing factors","volume":"20","author":"Sears WR","year":"2007","unstructured":"Sears WR, Duggal N, Sekhon LH, et al. Segmental malalignment with the Bryan cervical disc prosthesis\u2014contributing factors. Clin Spine Surg 2007; 20(2): 111\u2013117.","journal-title":"Clin Spine Surg"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.12659\/MSM.892712"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-015-0330-5"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-015-4281-7"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000002048"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2017.07.009"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3233\/BME-211247"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12008-017-0431-y"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2022.2089026"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-008-9534-8"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/09544119221135627"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181f5cb87"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002316"},{"issue":"4","key":"e_1_3_2_24_2","first-page":"215","article-title":"Guide for verification and validation in computational solid mechanics","volume":"44","author":"Schwer LE.","year":"2009","unstructured":"Schwer LE. Guide for verification and validation in computational solid mechanics. J Strain Anal Eng Des 2009; 44(4): 215\u2013224.","journal-title":"J Strain Anal Eng Des"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2005.01.010"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002128"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200112150-00012"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2014.02.020"},{"issue":"2","key":"e_1_3_2_29_2","first-page":"021004","article-title":"Biomechanical study of cervical disc arthroplasty devices using finite element modeling","volume":"4","author":"Yoganandan N","year":"2021","unstructured":"Yoganandan N, Purushothaman Y, Choi H, et al. Biomechanical study of cervical disc arthroplasty devices using finite element modeling. J Eng Sci Med Diagn Ther 2021; 4(2): 021004.","journal-title":"J Eng Sci Med Diagn Ther"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.842382"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e318273a2ea"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2021.106355"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-012-2486-6"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1502-5"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.12998\/wjcc.v8.i17.3890"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200211150-00003"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2019.07.011"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joca.2015.03.028"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.31616\/asj.2020.0117"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119231215721","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119231215721","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119231215721","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:28:40Z","timestamp":1777674520000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119231215721"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,16]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["10.1177\/09544119231215721"],"URL":"https:\/\/doi.org\/10.1177\/09544119231215721","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,16]]}}}