{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T20:36:01Z","timestamp":1777926961338,"version":"3.51.4"},"reference-count":45,"publisher":"SAGE Publications","issue":"10","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:p>The limitations faced by individuals with transtibial leg amputations highlight the need for rehabilitation devices with enhanced performance. Energy Storing and Returning (ESAR) prosthetic devices have emerged as a promising solution, utilizing innovative designs and materials to enhance the range of motion for these individuals. This study presents a workflow for evaluating J-shaped ESAR prosthetic blades under gait-specific conditions, investigating their behavior during various states of movement corresponding to the natural human gait cycle. A model based on the general structure of J-shaped below-knee prosthetic blades have been designed and simulated using different materials. The performance of the prosthesis has been evaluated during standing, walking, running, and hurdling. Finite Element analyses have been conducted using Abaqus CAE. OpenSim has been employed to simulate the natural gait cycle during walking and running, and the results have been utilized as loading input and boundary conditions for Abaqus simulations. Abaqus built-in Auricchio-Taylor Constitutive model has been utilized to simulate the super-elastic behavior of NiTinol. In the results section, various parameters such as von Mises stress, elastic strain, total deformation, strain energy, and mass have been compared. NiTinol composite and carbon fiber composite exhibited the best performance, with the carbon fiber composite being significantly lighter, weighing 68% less than NiTinol composite. The comprehensive method and procedure proposed in this study can be employed for further research in the field of prosthetic feet, as well as generalized for a wide range of rehabilitation devices.<\/jats:p>","DOI":"10.1177\/09544119251383275","type":"journal-article","created":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T04:36:31Z","timestamp":1761971791000},"page":"1026-1041","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["A workflow for evaluating J-shaped prosthetic blades using shape memory alloys: Finite element analysis and material comparison"],"prefix":"10.1177","volume":"239","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-4819-2622","authenticated-orcid":false,"given":"Reza","family":"Karimpour","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, University of Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5495-3630","authenticated-orcid":false,"given":"Mohammad Reza","family":"Zakerzadeh","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, University of Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,10,31]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4006436"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1053\/apmr.2002.34605"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.3390\/act9030074"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/PXR.0000000000000070"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0167-9457(84)90005-8"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0009307"},{"key":"e_1_3_2_8_2","first-page":"311","article-title":"Investigating the effect of viscoelastic ankle foot prosthesis on below-knee amputee gait cycle: Modeling and simulation","volume":"17","author":"Gharini M","year":"2017","unstructured":"Gharini M, Mohammadi Moghaddam M, Farahmand F. Investigating the effect of viscoelastic ankle foot prosthesis on below-knee amputee gait cycle: Modeling and simulation. mdrsjrns 2017; 17: 311\u2013321.","journal-title":"mdrsjrns"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1080\/10400435.2018.1493708"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1142\/S1758825121501246"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/0309364616682386"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/PXR.0000000000000246"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3390\/app11125591"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2020.09.331"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.humov.2011.08.005"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0229035"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-56479-8"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0189652"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.30464\/jmee.295"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1115\/IMECE2014-37293"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1109\/ICITACEE50144.2020.9239136"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.22214\/ijraset.2023.48876"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411911429534"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.eurpolymj.2024.113495"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2024.106719"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11665-011-9869-4"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2019.04.004"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1177\/09544062221105221"},{"key":"e_1_3_2_29_2","unstructured":"www.alleima.com. https:\/\/www.alleima.com\/ 2023."},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2016.2586891"},{"key":"e_1_3_2_31_2","volume-title":"Henry Dreyfuss A and with an introduction by Stephen BW. The measure of man and woman: human factors in design","author":"Alvin RT.","year":"2002","unstructured":"Alvin RT. Henry Dreyfuss A and with an introduction by Stephen BW. The measure of man and woman: human factors in design. Revis ed. Wiley, 2002. \u00a92002, 2002."},{"key":"e_1_3_2_32_2","first-page":"1","article-title":"Anthropometric reference data for children and adults: United States, 2015-2018. Vital & health statistics Series 3","volume":"36","author":"Fryar C","year":"2021","unstructured":"Fryar C, Carroll M, Gu Q, et al. Anthropometric reference data for children and adults: United States, 2015-2018. Vital & health statistics Series 3. Anal Epidemiol Stud 2021; 36: 1\u201344.","journal-title":"Anal Epidemiol Stud"},{"key":"e_1_3_2_33_2","first-page":"1503","article-title":"Anthropometric estimations for Iranian general population","volume":"48","author":"Saremi M","year":"2019","unstructured":"Saremi M, Kazemhaghighi M. Anthropometric estimations for Iranian general population. Iran J Public Health 2019; 48: 1503\u20131511.","journal-title":"Iran J Public Health"},{"key":"e_1_3_2_34_2","first-page":"35","article-title":"Waist circumference, weight, and body mass index of Iranians based on national non-communicable disease risk factors surveillance","volume":"41","author":"Ahranjani SHA","year":"2012","unstructured":"Ahranjani SHA, Kashani H, Forouzanfar M, et al. Waist circumference, weight, and body mass index of Iranians based on national non-communicable disease risk factors surveillance. Iran J Public Health 2012; 41: 35\u201345.","journal-title":"Iran J Public Health"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","unstructured":"Alizadeh Y. Design and structural analysis of composite prosthetic running blades for athletes: A case of dynamic explicit analysis using Abaqus CAE. 2020. DOI: 10.13140\/RG.2.2.20693.04327.","DOI":"10.13140\/RG.2.2.20693.04327"},{"key":"e_1_3_2_36_2","volume-title":"SMA UM: User material subroutine for thermomechanical constitutive model of shape memory alloys","author":"Lagoudas D","year":"2003","unstructured":"Lagoudas D, Bo Z, Qidwai S, et al. SMA UM: User material subroutine for thermomechanical constitutive model of shape memory alloys. College Station, TX: Texas A&M University. 2003."},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0207(20000228)47:6<1123::AID-NME817>3.0.CO;2-N"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1142\/S1758825118500400"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1177\/1045389X14522532"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1142\/S1758825124500406"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0045-7825(96)01147-4"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0045-7825(96)01232-7"},{"key":"e_1_3_2_43_2","volume-title":"Shape Memory Alloy Engineering: For Aerospace, Structural, and Biomedical Applications","author":"Sacco E","year":"2021","unstructured":"Sacco E, Lecce L, Auricchio F, et al. Shape Memory Alloy Engineering: For Aerospace, Structural, and Biomedical Applications. Woburn, MA: Butterworth-Heinemann, 2021."},{"key":"e_1_3_2_44_2","unstructured":"A joint publication of the Society of Automotive Engineers ASfT and materials. Metals & alloys in the unified numbering system: with a description of the system and a cross index of chemically similar specifications: SAE HS-1086 FEB93 ASTM DS-56 E. 6th ed. Society of Automotive Engineers American Society for Testing and Materials (ASfT and materials) 1993."},{"key":"e_1_3_2_45_2","first-page":"362","volume-title":"High Performance Control","author":"Tay TT","year":"1997","unstructured":"Tay TT, Moore J, Mareels I. High Performance Control. Birkhauser, 1997, p.362."},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.01.032"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119251383275","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119251383275","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119251383275","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:29:45Z","timestamp":1777674585000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119251383275"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":45,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1177\/09544119251383275"],"URL":"https:\/\/doi.org\/10.1177\/09544119251383275","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]}}}