{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T20:25:48Z","timestamp":1793305548672,"version":"4.5.0"},"reference-count":29,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2025,12,9]],"date-time":"2025-12-09T00:00:00Z","timestamp":1765238400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:p>Ulnar shortening osteotomy (USO) is a commonly used technique for treating ulnar impaction syndrome (UIS), but nonunion remains a non\u2013negligible complication. Currently, there is still no consensus on the best surgical protocol to prevent nonunion. There are limited studies on plate placement, which is a key factor influencing the mechanical environment at the osteotomy site. In this study, finite element analysis (FEA) was used to investigate the biomechanical differences between volar and dorsal plate fixation in USO. The results showed that the volar\u2013side plate model demonstrated superior initial stability with significantly lower interfragmentary strain than the dorsal\u2013side plate model, particularly under axial (48.6% reduction) and extension (38.3% reduction) loading. The von Mises stress analysis demonstrated the biomechanical superiority of the volar-side plate over dorsal-side plate in ulnar shortening osteotomy, as evidenced by lower stress values under four loadings, and more favorable stress distribution patterns, especially reduced stress concentrations at critical locations. These findings suggested that volar\u2013side plate fixation would provide better initial stability for healing, providing insights into optimizing surgical strategies for USO.<\/jats:p>","DOI":"10.1177\/09544119251398965","type":"journal-article","created":{"date-parts":[[2025,12,9]],"date-time":"2025-12-09T11:06:24Z","timestamp":1765278384000},"page":"25-33","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical evaluation of plate positioning in ulnar shortening osteotomy for nonunion prevention"],"prefix":"10.1177","volume":"240","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4629-8573","authenticated-orcid":false,"given":"Chun\u2013Lin","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu\u2013Fei","family":"Dai","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,12,9]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0266-7681(98)80090-9"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-194208000-00014"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.2000.jhsu025a0055"},{"key":"e_1_3_2_5_2","first-page":"612","article-title":"Ulnar shortening osteotomy: our experience","volume":"55","author":"Cardoso ANP","year":"2020","unstructured":"Cardoso ANP, Viegas R, Gamelas P, et al. Ulnar shortening osteotomy: our experience. Rev Bras Ortop 2020; 55: 612\u2013619.","journal-title":"Rev Bras Ortop"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2018.08.018"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2023.06.001"},{"key":"e_1_3_2_8_2","first-page":"677","article-title":"Nonunion after using procedure-specific instrumentations for ulnar shortening osteotomy","volume":"11","author":"Kasper AA","year":"2023","unstructured":"Kasper AA, Reddy Y, Plusch K, et al. Nonunion after using procedure-specific instrumentations for ulnar shortening osteotomy. Arch Bone Joint Surg 2023; 11: 677\u2013683.","journal-title":"Arch Bone Joint Surg"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12593-015-0201-7"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1142\/S2424835520500538"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(93)90065-B"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2017.03.010"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/os.13428"},{"key":"e_1_3_2_14_2","first-page":"441","article-title":"A study comparing the outcomes of transverse ulnar shortening osteotomy fixed with a DCP to oblique osteotomy fixed with a procedure specific plate","volume":"25","author":"Singhal R","year":"2020","unstructured":"Singhal R, Mehta N, Brown P, et al. A study comparing the outcomes of transverse ulnar shortening osteotomy fixed with a DCP to oblique osteotomy fixed with a procedure specific plate. J Hand Surg 2020; 25: 441\u2013446.","journal-title":"J Hand Surg"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2024.11.007"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02334-4"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2005.09.011"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mporth.2009.12.004"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411920985757"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.11.015"},{"key":"e_1_3_2_21_2","first-page":"175","article-title":"Physical and biological aspects of fracture healing with special reference to internal fixation","volume":"138","author":"Perren SM.","year":"1979","unstructured":"Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res 1979; 138: 175\u2013196.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2010.10.002"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2020.08.001"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11914-021-00690-y"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/J.JHSB.2005.12.009"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.03.002"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1080\/00140139.2016.1235233"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B8.0841093"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2024.111917"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104619"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119251398965","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119251398965","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119251398965","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:29:51Z","timestamp":1777674591000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119251398965"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,9]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1177\/09544119251398965"],"URL":"https:\/\/doi.org\/10.1177\/09544119251398965","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,9]]}}}