{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,24]],"date-time":"2026-05-24T10:05:07Z","timestamp":1779617107738,"version":"3.53.1"},"reference-count":69,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100025293","name":"Scoliosis Support and Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100025293","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000331","name":"british scoliosis research foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:p>\n                    Magnetically controlled growing rods are used for the surgical treatment of early onset scoliosis. However, one of the key concerns around the use of these rods is the extensive titanium alloy metallosis seen at revision surgery. To quantify the wear causing this metallosis, for the first time the internal wear volumes from magnetically controlled growing rods have been measured. A cohort of 30 retrieved rods was measured, from 18 cases (6 single rods and 12 dual rod constructs) after an average time in vivo of 1120 days. Another pair of rods explanted after 30\u2009days due to infection served as a negligible-wear datum to validate the methodology. From each retrieved rod, the wear volume of the extending bar component and of the outer casing component was measured. This was achieved through geometric measurements of the components, with the geometry of the internal aspect of the outer casings determined using a replicating compound and then measuring the replica. The average wear volume of the retrieved rods was 71.8 (21.2\u2013201.9) mm\n                    <jats:sup>3<\/jats:sup>\n                    which equated to an average wear rate of 23.4 (6.9\u201365.8) mm\n                    <jats:sup>3<\/jats:sup>\n                    \/year. Of the 32 rods measured, 21 were 90\u2009mm in length and 11 were 70\u2009mm in length. The 90\u2009mm rods showed a statistically significant greater wear than the 70\u2009mm rods (\n                    <jats:italic toggle=\"yes\">p<\/jats:italic>\n                    \u2009=\u20090.007); this may be attributed to the greater extension length available in the 90\u2009mm rods, and thus for greater wear under boundary lubrication. The wear volumes measured from the retrieved growing rods are substantial and of concern in this paediatric population.\n                  <\/jats:p>","DOI":"10.1177\/09544119261433151","type":"journal-article","created":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T05:48:10Z","timestamp":1775108890000},"page":"467-480","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Measurement of the wear volumes generated within retrieved magnetically controlled growing rods"],"prefix":"10.1177","volume":"240","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8497-5790","authenticated-orcid":false,"given":"Thomas J.","family":"Joyce","sequence":"first","affiliation":[{"name":"Department of Mechanical and Construction Engineering, Northumbria University, Newcastle, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,4,1]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2015.12.098"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamasurg.2025.4257"},{"key":"e_1_3_3_4_2","unstructured":"Food_and_drug_adminstration. 510(k) Summary - MAGEC Spinal Bracing and Distraction System. K140613. https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf14\/k140613.pdf (2022 accessed 8 December 2025)."},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s43441-024-00724-4"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000003439"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2015.12.020"},{"key":"e_1_3_3_8_2","unstructured":"NuVasive. Urgent Field Safety Notice\/MAGEC System. https:\/\/www.nuvasive.com\/wp-content\/uploads\/2019\/06\/Final_FSN_DATED-25JUN19.pdf (2019 accessed 6 December 2025)."},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002221"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002806"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000003215"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-024-08546-6"},{"key":"e_1_3_3_13_2","unstructured":"NuVasive. Urgent Field Safety Notice \/ MAGEC System https:\/\/mhra-gov.filecamp.com\/s\/3r2CxLcQILRPiATJ\/d (2020 accessed 6 December 2025)."},{"key":"e_1_3_3_14_2","unstructured":"MHRA. Targeted communication: CE mark suspended for all MAGEC systems manufactured by NuVasive Specialized Orthopedics Inc https:\/\/www.gov.uk\/drug-device-alerts\/targeted-communication-ce-mark-suspended-for-all-magec-systems-manufactured-by-nuvasive-specialized-orthopedics-inc (2021 accessed 6 December 2025)."},{"key":"e_1_3_3_15_2","unstructured":"NuVasive. Urgent field safety notice \u2013 MAGEC device system. https:\/\/www.nuvasive.com\/wp-content\/uploads\/2021\/12\/MAGEC_IFU_Update_FSN_12072021.pdf (2021 accessed 6 December 2025)."},{"key":"e_1_3_3_16_2","unstructured":"MHRA. MDA\/2020\/011 Spinal implant: All MAGEC Systems \u2013 supply suspended to the UK https:\/\/www.gov.uk\/drug-device-alerts\/spinal-implant-all-magec-systems-supply-suspended-to-the-uk-mda-2020-011 (2020 accessed 6 December 2025)."},{"key":"e_1_3_3_17_2","unstructured":"MHRA. MAGEC X System NuVasive Specialized Orthopedics (NSO): UK suspension lifted DSI\/2023\/003. https:\/\/assets.publishing.service.gov.uk\/media\/65f05bafff11700011615969\/DSI_-_MAGEC-_2024.002_12.03.2024.pdf (2023 accessed 6 December 2025)."},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B2.25150"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-021-06750-2"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.102B10.BJJ-2020-0842.R1"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000002526"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.98B12.38061"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000004406"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000001463"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1302\/1863-2548.13.180203"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/2309499019886945"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000002954"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.99B6.BJJ-2016-1102.R2"},{"key":"e_1_3_3_29_2","volume-title":"ISO12891-2: Retrieval and analysis of surgical implant \u2013 Part 2: Analysis of retrieved surgical implants","author":"International_Standards_Organisation","year":"2020","unstructured":"International_Standards_Organisation. ISO12891-2: Retrieval and analysis of surgical implant \u2013 Part 2: Analysis of retrieved surgical implants. ISO, 2020."},{"key":"e_1_3_3_30_2","volume-title":"ISO14242-2: Implants for surgery - wear of total hip joint prostheses, part 2. Methods of measurement","author":"International_Standards_Organisation","year":"2016","unstructured":"International_Standards_Organisation. ISO14242-2: Implants for surgery - wear of total hip joint prostheses, part 2. Methods of measurement. ISO, 2016."},{"key":"e_1_3_3_31_2","volume-title":"ISO14243-2: Implants for surgery. Wear of total knee-joint prostheses. Methods of measurement","author":"International_Standards_Organisation","year":"2016","unstructured":"International_Standards_Organisation. ISO14243-2: Implants for surgery. Wear of total knee-joint prostheses. Methods of measurement. ISO, 2016."},{"key":"e_1_3_3_32_2","volume-title":"ASTM-F732-17: Standard test method for wear testing of polymeric materials used in total joint prostheses","author":"American Society for Testing and Materials","year":"2017","unstructured":"American Society for Testing and Materials. ASTM-F732-17: Standard test method for wear testing of polymeric materials used in total joint prostheses. American Society for Testing and Materials, 2017."},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.4047\/jap.2021.13.6.343"},{"key":"e_1_3_3_34_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B2.25099"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wear.2011.07.009"},{"key":"e_1_3_3_36_2","unstructured":"Microset. Microset 101 fluid replicating compounds. https:\/\/www.microset.co.uk\/technical-info\/microset-101-fluid\/index.html (2025 accessed 11 December 2025)."},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.procir.2017.12.118"},{"key":"e_1_3_3_38_2","first-page":"537","volume-title":"Biomaterials science","author":"Ratner BD","year":"2004","unstructured":"Ratner BD, Hoffman AS, Schoen FJ, et al. (eds). Biomaterials science. 2nd ed. Elsevier Academic Press, 2004. pp.537.","edition":"2"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-021-06774-8"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-1038-9"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.103B.BJJ-2020-2555.R2"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1243\/095441105X63255"},{"key":"e_1_3_3_43_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B8.26040"},{"key":"e_1_3_3_44_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.22970"},{"key":"e_1_3_3_45_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.01262"},{"key":"e_1_3_3_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(12)60273-6"},{"key":"e_1_3_3_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.artd.2020.07.033"},{"key":"e_1_3_3_48_2","doi-asserted-by":"publisher","DOI":"10.1177\/17531934221113723"},{"key":"e_1_3_3_49_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-0044-1791531"},{"key":"e_1_3_3_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2021.121039"},{"key":"e_1_3_3_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/0043-1648(58)90428-9"},{"key":"e_1_3_3_52_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199306000-00004"},{"key":"e_1_3_3_53_2","doi-asserted-by":"publisher","DOI":"10.1590\/S1415-47572010005000118"},{"key":"e_1_3_3_54_2","volume-title":"Joint replacement in the human body","author":"Joyce TJ","year":"2024","unstructured":"Joyce TJ. Joint replacement in the human body. Elsevier, 2024."},{"key":"e_1_3_3_55_2","doi-asserted-by":"publisher","DOI":"10.1243\/PIME_PROC_1996_210_413_02"},{"key":"e_1_3_3_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(14)60037-4"},{"key":"e_1_3_3_57_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B4.14368"},{"key":"e_1_3_3_58_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000000660"},{"key":"e_1_3_3_59_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2015.11.040"},{"key":"e_1_3_3_60_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-15057-1"},{"key":"e_1_3_3_61_2","doi-asserted-by":"publisher","DOI":"10.1302\/2046-3758.33.2000249"},{"key":"e_1_3_3_62_2","doi-asserted-by":"publisher","DOI":"10.1177\/0954411914567552"},{"key":"e_1_3_3_63_2","doi-asserted-by":"publisher","DOI":"10.1302\/2046-3758.14.2000047"},{"key":"e_1_3_3_64_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.99B10.BJJ-2016-1005.R1"},{"key":"e_1_3_3_65_2","unstructured":"Renishaw. Technical specifications: styli and accessories https:\/\/www.renishaw.com\/media\/pdf\/en\/e0f30c2863ad4f94bea12ff5b7113634.pdf?srsltid=AfmBOoqsKP1ZqPT1VvN3BxveuVaMsbO2jeLUNUZlsKoDwtHHw_H4E6Jy (2020 accessed 6 December 2025)."},{"key":"e_1_3_3_66_2","first-page":"37","article-title":"Socket wear in Charnley low friction arthroplasty of the hip","volume":"1978","author":"Griffith MJ","unstructured":"Griffith MJ, Seidenstein MK, Williams D, et al. Socket wear in Charnley low friction arthroplasty of the hip. Clin Orthop Relat Res 1978; 137: 37\u201347.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_3_67_2","doi-asserted-by":"publisher","DOI":"10.1177\/21925682221096340"},{"key":"e_1_3_3_68_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.22652"},{"key":"e_1_3_3_69_2","unstructured":"Scientific Committee on Emerging Newly Identified Health Risks (SCENIHR). Final opinion on Metal-on-Metal joint replacements https:\/\/ec.europa.eu\/health\/scientific_committees\/consultations\/public_consultations\/scenihr_consultation_20_en (2014 accessed 6 December 2025)."},{"key":"e_1_3_3_70_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2025.2281"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119261433151","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119261433151","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119261433151","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,24]],"date-time":"2026-05-24T09:47:53Z","timestamp":1779616073000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119261433151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":69,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1177\/09544119261433151"],"URL":"https:\/\/doi.org\/10.1177\/09544119261433151","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]}}}