{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T21:59:46Z","timestamp":1781819986785,"version":"3.54.5"},"reference-count":41,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:p>The camera calibration process (CCP) is an essential procedure in computer vision techniques (CVT) affecting the 3D reconstruction accuracy as it involves computing the parameters needed to determine 3D information from 2D images. The CCP performance depends on the model used to approximate the camera behavior, and on the intrinsic and extrinsic conditions used. Inadequate CCP conditions may result in large 3D reconstruction errors. Although in human gait analysis (HGA) applications some works have focused on studying the influence of CCP conditions on the reconstruction accuracy, there is a lack of methodological guidelines on optimal calibration conditions. In order to bridge this research gap, in this paper an investigation to evaluate the influence of the CCP conditions, such as the number of calibration points, camera type, image size and calibration pattern size, on the accuracy of 3D reconstruction for HGA, is presented. A linear CVT based on the Direct Linear Transformation (DLT) algorithm was selected. The results have shown that the 3D reconstruction accuracy increases with the number of calibration points, the quality of the cameras, the image size and the calibration pattern size. Adequate reconstruction errors for HGA (smaller than 1%) can be obtained when using the homogeneous CVT, 24 calibration points, conventional cameras, image size of 1280\u2009pixels\u2009\u00d7\u20091024\u2009pixels, and a large calibration pattern (1.2\u2009m\u2009\u00d7\u20090.7\u2009m\u2009\u00d7\u20091.0\u2009m). This CVT and CCP conditions can be obtained with relatively low-cost equipment, making it attractive for clinical use in low-income countries.<\/jats:p>","DOI":"10.1177\/09544119261444092","type":"journal-article","created":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T07:08:17Z","timestamp":1777014497000},"page":"555-566","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Influence of the camera calibration process on the accuracy of vision-based 3D reconstruction for human gait analysis"],"prefix":"10.1177","volume":"240","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5342-3849","authenticated-orcid":false,"given":"Juan C.","family":"Arellano-Gonz\u00e1lez","sequence":"first","affiliation":[{"name":"Facultad de Ingenieria, Universidad Aut\u00f3noma de San Luis Potos\u00ed, M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2827-9547","authenticated-orcid":false,"given":"Hugo I.","family":"Medell\u00edn-Castillo","sequence":"additional","affiliation":[{"name":"Facultad de Ingenieria, Universidad Aut\u00f3noma de San Luis Potos\u00ed, M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauro E.","family":"Maya-M\u00e9ndez","sequence":"additional","affiliation":[{"name":"Facultad de Ingenieria, Universidad Aut\u00f3noma de San Luis Potos\u00ed, M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Soubervielle-Montalvo","sequence":"additional","affiliation":[{"name":"Facultad de Ingenieria, Universidad Aut\u00f3noma de San Luis Potos\u00ed, M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario G.","family":"Bernal-Torres","sequence":"additional","affiliation":[{"name":"Facultad de Ingenieria, Universidad Aut\u00f3noma de San Luis Potos\u00ed, M\u00e9xico"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,4,24]]},"reference":[{"key":"e_1_3_3_2_2","unstructured":"WHO. World Health Organization. https:\/\/www.who.int\/features\/factfiles\/disability\/es\/ (2026 accessed 2 March 2026)."},{"key":"e_1_3_3_3_2","unstructured":"World Bank. Disability. https:\/\/www.banco-mundial.org\/es\/topic\/disability (2026 accessed 2 March 2026)."},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-016-1013-z"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2019.10.024"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2017.12.002"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.conengprac.2019.06.003"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmedt.2022.901331"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1080\/01942638.2022.2037808"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.3390\/s140203362"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelekin.2015.10.007"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9780511811685"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-13-6861-5_61"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/34.888718"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.3390\/app8040644"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10044-024-01264-1"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.3390\/biomimetics9120740"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11042-025-20846-7"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2025.3608639"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.3390\/s23167039"},{"issue":"2","key":"e_1_3_3_21_2","first-page":"437","article-title":"Analysis of the kinematic variation of human gait under different walking conditions using computer vision","volume":"38","author":"Arellano-Gonzalez JC","year":"2017","unstructured":"Arellano-Gonzalez JC, Medellin-Castillo HI, Cardenas-Galindo JA. Analysis of the kinematic variation of human gait under different walking conditions using computer vision. Rev Mex Ing Biomed 2017; 38(2): 437\u2013457.","journal-title":"Rev Mex Ing Biomed"},{"key":"e_1_3_3_22_2","volume-title":"An\u00e1lisis cinem\u00e1tico de la marcha humana bajo diversas condiciones extr\u00ednsecas utilizando t\u00e9cnicas de visi\u00f3n por computadora","author":"Arellano-Gonzalez JC","year":"2022","unstructured":"Arellano-Gonzalez JC. An\u00e1lisis cinem\u00e1tico de la marcha humana bajo diversas condiciones extr\u00ednsecas utilizando t\u00e9cnicas de visi\u00f3n por computadora. PhD. Thesis, Universidad de Guanajuato, 2022."},{"key":"e_1_3_3_23_2","volume-title":"Introduction to sport in biomechanics, analyzing human movement patterns","author":"Bartlett R","year":"2014","unstructured":"Bartlett R. Introduction to sport in biomechanics, analyzing human movement patterns. Taylor & Francis Group, 2014."},{"key":"e_1_3_3_24_2","volume-title":"Desarrollo de un sistema de pruebas para el an\u00e1lisis biomec\u00e1nico del caminado humano utilizando t\u00e9cnicas de visi\u00f3n por computadora","author":"Bernal-Torres M","year":"2018","unstructured":"Bernal-Torres M. Desarrollo de un sistema de pruebas para el an\u00e1lisis biomec\u00e1nico del caminado humano utilizando t\u00e9cnicas de visi\u00f3n por computadora. Master Thesis, Universidad Autonoma de San Luis Potosi, 2018."},{"key":"e_1_3_3_25_2","volume-title":"Color atlas of skeletal landmark definitions","author":"Van Sint Jan S","year":"2007","unstructured":"Van Sint Jan S (ed.). Color atlas of skeletal landmark definitions. 1st ed. Churchill Livingstone\/Elsevier, 2007.","edition":"1"},{"issue":"1","key":"e_1_3_3_26_2","article-title":"Are action sport cameras accurate enough for 3D motion analysis? A comparison with a commercial motion capture system","volume":"35","author":"Bernardina GRD","year":"2019","unstructured":"Bernardina GRD, Monnet T, Pinto HT, et al. Are action sport cameras accurate enough for 3D motion analysis? A comparison with a commercial motion capture system. J Appl Biomech 2019; 35(1): 80\u201386\u201386.","journal-title":"J Appl Biomech"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1038\/srep10909"},{"key":"e_1_3_3_28_2","volume-title":"Biomechanical evaluation of movement in sport and exercise","author":"Payton CJ","year":"2008","unstructured":"Payton CJ, Bartlett R. Biomechanical evaluation of movement in sport and exercise. Taylor & Francis Group, 2008."},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1590\/1518-8345.3499.3282"},{"issue":"3","key":"e_1_3_3_30_2","first-page":"576","article-title":"Temporo-spatial gait adaptations while walking on different surfaces in Latino-Hispanic adults with controlled type II diabetes","volume":"17","author":"Rosario MG","year":"2022","unstructured":"Rosario MG, Mbue ND, Jose A. Temporo-spatial gait adaptations while walking on different surfaces in Latino-Hispanic adults with controlled type II diabetes. J Hum Sport Exerc 2022; 17(3): 576\u2013585.","journal-title":"J Hum Sport Exerc"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1080\/1059924X.2015.1074971"},{"issue":"44","key":"e_1_3_3_32_2","first-page":"135","article-title":"Evaluaci\u00f3n preliminar de la marcha en individuos sanos","volume":"11","author":"Diaz-Novo C","year":"2007","unstructured":"Diaz-Novo C, L\u00f3pez-Rios N, Montoya-Pedron A, et al. Evaluaci\u00f3n preliminar de la marcha en individuos sanos. Universidad, Ciencia y Tecnolog\u00eda 2007; 11(44): 135\u2013140.","journal-title":"Universidad, Ciencia y Tecnolog\u00eda"},{"issue":"1","key":"e_1_3_3_33_2","first-page":"29","article-title":"Marcha: descripci\u00f3n, m\u00e9todos, herramientas de evaluaci\u00f3n y par\u00e1metros de normalidad reportados en la literatura","volume":"1","author":"Agudelo-Mendoza AI","year":"2013","unstructured":"Agudelo-Mendoza AI, Bri\u00f1ez-Santamaria TJ, Guar\u00edn-Urrego V, et al. Marcha: descripci\u00f3n, m\u00e9todos, herramientas de evaluaci\u00f3n y par\u00e1metros de normalidad reportados en la literatura. Revista CES Movimiento y Salud 2013; 1(1): 29\u201343.","journal-title":"Revista CES Movimiento y Salud"},{"issue":"2","key":"e_1_3_3_34_2","article-title":"Gait speed is associated with executive function in Latin American older adults from LatAmFINGERS","volume":"9","author":"Guti\u00e9rrez M","year":"2025","unstructured":"Guti\u00e9rrez M, Marroig A, Delgado C, et al. Gait speed is associated with executive function in Latin American older adults from LatAmFINGERS. Innov Aging 2025; 9(2): 122.4128.","journal-title":"Innov Aging"},{"key":"e_1_3_3_35_2","doi-asserted-by":"publisher","DOI":"10.4067\/s0034-98872024000500531"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.15446\/revfacmed.v68n1.71690"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00189-1"},{"key":"e_1_3_3_38_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-5-13"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0966-6362(03)00068-7"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2003.11.003"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-004-1041-5"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2010.03.010"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119261444092","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119261444092","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119261444092","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T21:47:07Z","timestamp":1781819227000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119261444092"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,24]]},"references-count":41,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1177\/09544119261444092"],"URL":"https:\/\/doi.org\/10.1177\/09544119261444092","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,24]]}}}