{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T13:10:51Z","timestamp":1789564251554,"version":"build-2803163510"},"reference-count":50,"publisher":"SAGE Publications","issue":"9","license":[{"start":{"date-parts":[[2026,8,16]],"date-time":"2026-08-16T00:00:00Z","timestamp":1786838400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proc Inst Mech Eng H"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:p>This study evaluates the biomechanical influence of surface texturing and hybrid coatings on stress distribution and marginal bone loss (MBL) in dental implants under varying bone loss conditions and axial loading. A parametric three-dimensional finite element model (FEM) of the human mandible was developed, consisting of cortical and cancellous bone layers. Five implant surface textures\u2014Dome, Straight, U-Shape, X-Shape, and V-Shape\u2014were considered, along with four hybrid coatings: hydroxyapatite (HA), HA with 3% tantalum pentoxide (HA3TO), HA with 3% strontium (HA3Sr), and HA with a combination of 1.5% tantalum pentoxide and 1.5% strontium (HA1.5TO1.5Sr). The implants were subjected to static axial loads (100, 150, 200, and 250\u2009N). The V-Shape implant with HA1.5TO1.5SR exhibited the highest implant stress (97.13\u2009MPa at 250\u2009N), exceeding the 35\u2009MPa cortical bone yield threshold, indicating an increased risk of mechanical overload and resorption. Dome-Shape and U-Shape textures demonstrated improved stress distribution, reducing peak stresses and enhancing stability. Hybrid coatings lowered implant stress by 19.65%, mitigating bone remodeling risks. Bone loss amplified stress concentrations, with higher micromotion risks observed in V-Shape and Straight-Shape textures. Surface texturing and hybrid coatings significantly influence peri-implant stress and stability. Based on our findings, Dome-Shape and U-Shape textures, combined with hybrid coatings, offer biomechanical advantages for implant longevity. These findings support the clinical preference for coated, curved-surface implants, particularly in patients with compromised bone quality.<\/jats:p>","DOI":"10.1177\/09544119261477915","type":"journal-article","created":{"date-parts":[[2026,8,16]],"date-time":"2026-08-16T15:32:20Z","timestamp":1786894340000},"page":"935-945","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical evaluation of surface texturing and hybrid coatings in dental implants: A finite element analysis of stress distribution under bone loss conditions"],"prefix":"10.1177","volume":"240","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0633-9825","authenticated-orcid":false,"given":"Vamsi Krishna","family":"Dommeti","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, College of Engineering and Technology, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohadese","family":"Rajaeirad","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pechimuthu Susai","family":"Manickam","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, College of Engineering and Technology, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Balamurugan","family":"Subramanian","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, College of Engineering and Technology, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Valente","sequence":"additional","affiliation":[{"name":"Department of Innovative Technologies in Medicine &amp; Dentistry, University \u201cG. d\u2019Annunzio\u201d of Chieti-Pescara, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raphael","family":"Richert","sequence":"additional","affiliation":[{"name":"Facult\u00e9 d\u2019Odontologie, Universit\u00e9 Claude Bernard Lyon, Universit\u00e9 de Lyon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6888-272X","authenticated-orcid":false,"given":"Sandipan","family":"Roy","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, College of Engineering and Technology, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,8,16]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"crossref","unstructured":"Compton SM Clark D Chan S et al. Dental implants in the elderly population: a long-term follow-up. Int J Oral Maxillofac Implants 2017; 32: 164\u2013170. https:\/\/doi.org\/10.11607\/jomi.5305","DOI":"10.11607\/jomi.5305"},{"key":"e_1_3_2_3_2","doi-asserted-by":"crossref","unstructured":"Ball J Darby I. Mental health and periodontal and peri-implant diseases. Periodontol 2000 2022; 90: 106\u2013124. https:\/\/doi.org\/10.1111\/prd.12452","DOI":"10.1111\/prd.12452"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/9781119140474.ch2"},{"key":"e_1_3_2_5_2","doi-asserted-by":"crossref","unstructured":"Deshmukh P Dhatrak P. Influence of marginal bone loss with variable mandibular bone densities under masticatory loading using finite element analysis. Regen Eng Transl Med 2026; 12: 810\u2013825. https:\/\/doi.org\/10.1007\/s40883-025-00451-8","DOI":"10.1007\/s40883-025-00451-8"},{"key":"e_1_3_2_6_2","doi-asserted-by":"crossref","unstructured":"Qian J Wennerberg A Albrektsson T. Reasons for marginal bone loss around oral implants. Clin Implant Dent Relat Res 2012; 14: 792\u2013807. https:\/\/doi.org\/10.1111\/cid.12014","DOI":"10.1111\/cid.12014"},{"key":"e_1_3_2_7_2","first-page":"95","article-title":"Current interpretations of the osseointegrated response: clinical significance","volume":"6","author":"Albrektsson T","year":"1993","unstructured":"Albrektsson T, Zarb GA. Current interpretations of the osseointegrated response: clinical significance. Int J Prosthodont 1993; 6: 95\u2013105.","journal-title":"Int J Prosthodont"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(89)90081-4"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1996.070405.x"},{"key":"e_1_3_2_10_2","doi-asserted-by":"crossref","unstructured":"Lai HC Si MS Zhuang LF et al. Long-term outcomes of short dental implants supporting single crowns in posterior region: a clinical retrospective study of 5-10 years. Clin Oral Implants Res 2013; 24: 230\u2013237. https:\/\/doi.org\/10.1111\/j.1600-0501.2012.02452.x","DOI":"10.1111\/j.1600-0501.2012.02452.x"},{"key":"e_1_3_2_11_2","doi-asserted-by":"crossref","unstructured":"Elkattan A Torres-Vel\u00e1zquez N Bl\u00e1zquez-Hinarejos M et al. Marginal bone loss around bone-level and tissue-level implants: A systematic review and meta-analysis. Appl Sci 2025; 15: 2286. https:\/\/doi.org\/10.3390\/app15052286","DOI":"10.3390\/app15052286"},{"key":"e_1_3_2_12_2","doi-asserted-by":"crossref","unstructured":"Kowalski J Lapinska B Nissan J et al. Factors influencing marginal bone loss around dental implants: a narrative review. Coatings 2021; 11: 865. https:\/\/doi.org\/10.3390\/coatings11070865","DOI":"10.3390\/coatings11070865"},{"key":"e_1_3_2_13_2","doi-asserted-by":"crossref","unstructured":"Ruiz Garc\u00eda A Lijnev A Soleymani F et al. Bone remodeling and marginal bone loss of simplified versus conventional drilling: a randomized clinical trial. Bioengineering 2025; 12: 178. https:\/\/doi.org\/10.3390\/bioengineering12020178","DOI":"10.3390\/bioengineering12020178"},{"key":"e_1_3_2_14_2","doi-asserted-by":"crossref","unstructured":"Hashim D Cionca N. A comprehensive review of peri-implantitis risk factors. Curr Oral Health Rep 2020; 7: 262\u2013273. https:\/\/doi.org\/10.1007\/s40496-020-00274-2","DOI":"10.1007\/s40496-020-00274-2"},{"key":"e_1_3_2_15_2","first-page":"11","article-title":"Optimal selection of dental implant for different bone conditions based on the mechanical response","volume":"19","author":"Roy S","year":"2017","unstructured":"Roy S, Das M, Chakraborty P, et al. Optimal selection of dental implant for different bone conditions based on the mechanical response. Acta Bioeng Biomech 2017; 19: 11\u201320.","journal-title":"Acta Bioeng Biomech"},{"key":"e_1_3_2_16_2","doi-asserted-by":"crossref","unstructured":"Drai A Merdji A Albedah A et al. Effect of dental implantology on the biomechanical behavior of alveolar bone. Int J Multiscale Comput Eng 2018; 16: 579\u2013593. https:\/\/doi.org\/10.1615\/intjmultcompeng.2018028717","DOI":"10.1615\/IntJMultCompEng.2018028717"},{"key":"e_1_3_2_17_2","doi-asserted-by":"crossref","unstructured":"Bing L Mito T Yoda N et al. Effect of peri-implant bone resorption on mechanical stress in the implant body: in vivo measured load-based finite element analysis. J Oral Rehabil 2020; 47: 1566\u20131573. https:\/\/doi.org\/10.1111\/joor.13097","DOI":"10.1111\/joor.13097"},{"key":"e_1_3_2_18_2","doi-asserted-by":"crossref","unstructured":"Deshmukh P Dhatrak P. Evaluating the feasibility of short dental implants as alternatives to long dental implants in mandibular bone: a finite element study. J Biomed Mater Res B Appl Biomater 2024; 112: e35481. https:\/\/doi.org\/10.1002\/jbm.b.35481","DOI":"10.1002\/jbm.b.35481"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2003.08.008"},{"key":"e_1_3_2_20_2","doi-asserted-by":"crossref","unstructured":"Lemos CAA Verri FR Noritomi PY et al. Effect of bone quality and bone loss level around internal and external connection implants: a finite element analysis study. J Prosthet Dent 2021; 125: 137.e1\u2013137.e10. https:\/\/doi.org\/10.1016\/j.prosdent.2020.06.029","DOI":"10.1016\/j.prosdent.2020.06.029"},{"key":"e_1_3_2_21_2","doi-asserted-by":"crossref","unstructured":"Kurup A Dhatrak P Khasnis N. Surface modification techniques of titanium and titanium alloys for biomedical dental applications: A review. Mater Today Proc 2021; 39: 84\u201390. https:\/\/doi.org\/10.1016\/j.matpr.2020.06.163","DOI":"10.1016\/j.matpr.2020.06.163"},{"key":"e_1_3_2_22_2","doi-asserted-by":"crossref","unstructured":"Kittur N Oak R Dekate D et al. Dental implant stability and its measurements to improve osseointegration at the bone-implant interface: A review. Mater Today Proc 2021; 43: 1064\u20131070. https:\/\/doi.org\/10.1016\/j.matpr.2020.08.243","DOI":"10.1016\/j.matpr.2020.08.243"},{"key":"e_1_3_2_23_2","doi-asserted-by":"crossref","unstructured":"Andersen OZ Offermanns V Sillassen M et al. Accelerated bone ingrowth by local delivery of strontium from surface functionalized titanium implants. Biomaterials 2013; 34: 5883\u20135890. https:\/\/doi.org\/10.1016\/j.biomaterials.2013.04.031","DOI":"10.1016\/j.biomaterials.2013.04.031"},{"key":"e_1_3_2_24_2","doi-asserted-by":"crossref","unstructured":"Lu RJ Wang X He HX et al. Tantalum-incorporated hydroxyapatite coating on titanium implants: its mechanical and in vitro osteogenic properties. J Mater Sci Mater Med 2019; 30: 111\u2013114. https:\/\/doi.org\/10.1007\/s10856-019-6308-9","DOI":"10.1007\/s10856-019-6308-9"},{"key":"e_1_3_2_25_2","doi-asserted-by":"crossref","unstructured":"Barfeie A Wilson J Rees J. Implant surface characteristics and their effect on osseointegration. Br Dent J 2015; 218: E9. https:\/\/doi.org\/10.1038\/sj.bdj.2015.171","DOI":"10.1038\/sj.bdj.2015.171"},{"key":"e_1_3_2_26_2","doi-asserted-by":"crossref","unstructured":"Tang W Fischer NG Kong X et al. Hybrid coatings on dental and orthopedic titanium implants: current advances and challenges. BMEMat 2024; 2: e12105. https:\/\/doi.org\/10.1002\/bmm2.12105","DOI":"10.1002\/bmm2.12105"},{"key":"e_1_3_2_27_2","doi-asserted-by":"crossref","unstructured":"Alshadidi AAF Dommeti VK Aldosari LIN et al. Influence of surface texturing and coatings on mechanical properties and integration with bone tissue: an in silico study. Front Bioeng Biotechnol 2024; 12. https:\/\/doi.org\/10.3389\/fbioe.2024.1439262","DOI":"10.3389\/fbioe.2024.1439262"},{"key":"e_1_3_2_28_2","doi-asserted-by":"crossref","unstructured":"Dommeti VK Pramanik S Roy S. Influence of hydroxyapatite composite coating on the textured surface of patient specific dental implant: an in silico 3D finite element study. Mech Adv Mater Struct 2024; 31: 631\u2013639. https:\/\/doi.org\/10.1080\/15376494.2022.2116760","DOI":"10.1080\/15376494.2022.2116760"},{"key":"e_1_3_2_29_2","doi-asserted-by":"crossref","unstructured":"Ouldyerou A Merdji A Aminallah L et al. Biomechanical evaluation of marginal bone loss in the surrounding bone under different loading: 3D finite element analysis study. Int J Multiscale Comput Eng 2022; 20: 43\u201356. https:\/\/doi.org\/10.1615\/intjmultcompeng.2022043707","DOI":"10.1615\/IntJMultCompEng.2022043707"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.37190\/ABB-01757-2020-05"},{"key":"e_1_3_2_31_2","doi-asserted-by":"crossref","unstructured":"Dommeti VK Pramanik S Roy S. Mechanical response of different types of surface texture for medical application using finite element study. Proc Inst Mech Eng H J Eng Med 2021; 235: 717\u2013725. https:\/\/doi.org\/10.1177\/09544119211002722","DOI":"10.1177\/09544119211002722"},{"key":"e_1_3_2_32_2","doi-asserted-by":"crossref","unstructured":"Ercal P Taysi AE Ayvalioglu DC et al. Impact of peri-implant bone resorption prosthetic materials and crown to implant ratio on the stress distribution of short implants: a finite element analysis. Med Biol Eng Comput 2021; 59: 813\u2013824. https:\/\/doi.org\/10.1007\/s11517-021-02342-w","DOI":"10.1007\/s11517-021-02342-w"},{"key":"e_1_3_2_33_2","doi-asserted-by":"crossref","unstructured":"Santiago JF Verri FR Almeida DADF et al. Finite element analysis on influence of implant surface treatments connection and bone types. Mater Sci Eng C 2016; 63: 292\u2013300. https:\/\/doi.org\/10.1016\/j.msec.2016.02.061","DOI":"10.1016\/j.msec.2016.02.061"},{"key":"e_1_3_2_34_2","doi-asserted-by":"crossref","unstructured":"Rajaeirad M Fakharifar A Posti MHZ et al. Evaluating the effect of functionally graded materials on bone remodeling around dental implants. Dent Mater 2024; 40: 858\u2013868. https:\/\/doi.org\/10.1016\/j.dental.2024.04.002","DOI":"10.1016\/j.dental.2024.04.002"},{"key":"e_1_3_2_35_2","doi-asserted-by":"crossref","unstructured":"Pellizzer EP Lemos CAA Almeida DAF et al. Biomechanical analysis of different implant-abutments interfaces in different bone types: an in silico analysis. Mater Sci Eng C 2018; 90: 645\u2013650. https:\/\/doi.org\/10.1016\/j.msec.2018.05.012","DOI":"10.1016\/j.msec.2018.05.012"},{"key":"e_1_3_2_36_2","doi-asserted-by":"crossref","unstructured":"Dommeti VK Roy S Pramanik S et al. Design and development of tantalum and strontium ion doped hydroxyapatite composite coating on titanium substrate: structural and human osteoblast-like cell viability studies. Materials 2023; 16: 1499. https:\/\/doi.org\/10.3390\/ma16041499","DOI":"10.3390\/ma16041499"},{"key":"e_1_3_2_37_2","doi-asserted-by":"crossref","unstructured":"Dhatrak P Girme V Shirsat U et al. Significance of orthotropic material models to predict stress around bone-implant interface using numerical simulation. BioNanoScience 2019; 9: 652\u2013659. https:\/\/doi.org\/10.1007\/s12668-019-00649-5","DOI":"10.1007\/s12668-019-00649-5"},{"key":"e_1_3_2_38_2","doi-asserted-by":"crossref","unstructured":"Duan XB Wu TX Guo YC et al. Marginal bone loss around non-submerged implants is associated with salivary microbiome during bone healing. Int J Oral Sci 2017; 9: 95\u2013103. https:\/\/doi.org\/10.1038\/ijos.2017.18","DOI":"10.1038\/ijos.2017.18"},{"key":"e_1_3_2_39_2","doi-asserted-by":"crossref","unstructured":"Paracchini L Barbieri C Redaelli M et al. Finite element analysis of a new dental implant design optimized for the desirable stress distribution in the surrounding bone region. Prosthes 2020; 2: 225\u2013236. https:\/\/doi.org\/10.3390\/prosthesis2030019","DOI":"10.3390\/prosthesis2030019"},{"key":"e_1_3_2_40_2","doi-asserted-by":"crossref","unstructured":"Shinya A Ishida Y Miura D et al. The effect of implant length and diameter on stress distribution around single implant placement in 3D posterior mandibular FE model directly constructed form in vivo CT. Materials 2021; 14: 7344. https:\/\/doi.org\/10.3390\/ma14237344","DOI":"10.3390\/ma14237344"},{"key":"e_1_3_2_41_2","doi-asserted-by":"crossref","unstructured":"Khaohoen A Sornsuwan T Chaijareenont P et al. Biomaterials and clinical application of dental implants in relation to bone density-a narrative review. J Clin Med 2023; 12: 6924. https:\/\/doi.org\/10.3390\/jcm12216924","DOI":"10.3390\/jcm12216924"},{"key":"e_1_3_2_42_2","doi-asserted-by":"crossref","unstructured":"Korabi R Shemtov-Yona K Dorogoy A et al. The failure envelope concept applied to the bone-dental implant system. Sci Rep 2017; 7: 2051. https:\/\/doi.org\/10.1038\/s41598-017-02282-2","DOI":"10.1038\/s41598-017-02282-2"},{"key":"e_1_3_2_43_2","first-page":"83","article-title":"Effects of implant design and occlusal loading on bone remodeling in implant supported single crown: a finite element study","volume":"42","author":"Monstaporn M","year":"2021","unstructured":"Monstaporn M, Rungsiyakull P, Rungsiyakull C, et al. Effects of implant design and occlusal loading on bone remodeling in implant supported single crown: a finite element study. Chiang Mai Dent J CMDJ 2021; 42: 83\u201396.","journal-title":"Chiang Mai Dent J CMDJ"},{"key":"e_1_3_2_44_2","doi-asserted-by":"crossref","unstructured":"Grassi R Silva FFVE Musella G et al. Bone remodeling around implants with different macro-design placed in post-extraction sockets: a cone-beam computed tomography (CBCT) randomized controlled clinical trial (RCT). Dent J 2025; 13: 78. https:\/\/doi.org\/10.3390\/dj13020078","DOI":"10.3390\/dj13020078"},{"key":"e_1_3_2_45_2","doi-asserted-by":"crossref","unstructured":"Kayaba\u015f\u0131 O Y\u00fczbas\u0131o\u011flu E Erzincanl\u0131 F. Static dynamic and fatigue behaviors of dental implant using finite element method. Adv Eng Softw 2006; 37: 649\u2013658. https:\/\/doi.org\/10.1016\/j.advengsoft.2006.02.004","DOI":"10.1016\/j.advengsoft.2006.02.004"},{"key":"e_1_3_2_46_2","doi-asserted-by":"crossref","unstructured":"Hindurao B Gujare A Jadhav H et al. Evaluate the effect of bone density variation on stress distribution at the bone-implant interface using numerical analysis. Proc Inst Mech Eng H J Eng Med 2024; 238: 463\u2013470. https:\/\/doi.org\/10.1177\/09544119241240940","DOI":"10.1177\/09544119241240940"},{"key":"e_1_3_2_47_2","doi-asserted-by":"crossref","unstructured":"Joshi S Dhatrak P Nimbalkar S et al. An effect of various parameters on insertion torque to improve the success rate of dental implantation: A review. Mater Today Proc 2021; 43: 928\u2013934. https:\/\/doi.org\/10.1016\/j.matpr.2020.07.222","DOI":"10.1016\/j.matpr.2020.07.222"},{"key":"e_1_3_2_48_2","doi-asserted-by":"crossref","unstructured":"Dommeti VK Pramanik S Roy S. Design of customized coated dental implants using finite element analysis. Dent Med Probl 2023; 60: 385\u2013392. https:\/\/doi.org\/10.17219\/dmp\/142447","DOI":"10.17219\/dmp\/142447"},{"key":"e_1_3_2_49_2","doi-asserted-by":"publisher","DOI":"10.1080\/03091900600861616"},{"key":"e_1_3_2_50_2","doi-asserted-by":"crossref","unstructured":"Neto JVC Teixeira ABV C\u00e2ndido Dos Reis A. Hydroxyapatite coatings versus osseointegration in dental implants: a systematic review. J Prosthet Dent 2025; 134: 92\u201399. https:\/\/doi.org\/10.1016\/j.prosdent.2023.09.019","DOI":"10.1016\/j.prosdent.2023.09.019"},{"key":"e_1_3_2_51_2","doi-asserted-by":"crossref","unstructured":"Nuswantoro NF Manjas M Suharti N et al. Effect of hydroxyapatite coating thickness on inflammation and osseointegration of Ti\u201329Nb\u201313Ta-4.6Zr (TNTZ) implants. J Mater Res Technol 2024; 30: 6210\u20136217. https:\/\/doi.org\/10.1016\/j.jmrt.2024.05.013","DOI":"10.1016\/j.jmrt.2024.05.013"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119261477915","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09544119261477915","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09544119261477915","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T12:49:06Z","timestamp":1789562946000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09544119261477915"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,16]]},"references-count":50,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["10.1177\/09544119261477915"],"URL":"https:\/\/doi.org\/10.1177\/09544119261477915","relation":{},"ISSN":["0954-4119","2041-3033"],"issn-type":[{"value":"0954-4119","type":"print"},{"value":"2041-3033","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,16]]}}}