{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T16:56:16Z","timestamp":1789404976846,"version":"build-2803163510"},"reference-count":44,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2024,12,10]],"date-time":"2024-12-10T00:00:00Z","timestamp":1733788800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"The National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["32260235"],"award-info":[{"award-number":["32260235"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Bio-Medical Materials and Engineering"],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Titanium (Ti) and polyether ether ketone (PEEK) interbody fusion cages cause postoperative stress shielding problems. The porous cage design is one of the solutions advanced to mitigate this problem.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Exploring the mitigation of stress shielding with a porous interbody fusion cage after surgery for idiopathic scoliosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The porous interbody fusion cage was constructed based on the multiscale topology optimisation method, and the postoperative lumbar spine models implanted with it. The porous Ti and PEEK fusion cages were evaluated under physiological conditions to investigate their mechanical properties.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The volume of the porous fusion cage was reduced by 52.57%, and the stress was increased by 242.76% and 252.46% compared with the Ti and PEEK fusion cage; the modulus of elasticity of the porous fusion cage was reduced by 76.85%, and the strain was increased by 131.40%\u223c686.51% compared with the Ti cage; the porous fusion cage increased L3 cortical bone stress by 13.36% and 13.52% and cancellous bone by 82.93% and 76.72%, respectively, compared with the original interbody fusion cages.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The porous interbody fusion cage has a much more lightweight design which facilitates growth of bone tissue. However, a frame structure should be constructed to minimize issues with stress peaks and localised stress concentrations. It also has a significantly lower stiffness which helps alleviate vertebral stress shielding, further fostering bone growth. The porous fusion cage thus meets the clinical requirements for better fusion outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/09592989241303291","type":"journal-article","created":{"date-parts":[[2024,12,10]],"date-time":"2024-12-10T05:52:36Z","timestamp":1733809956000},"page":"110-123","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Multi-scale topology optimisation design and mechanical property analysis of porous interbody fusion cage"],"prefix":"10.1177","volume":"36","author":[{"given":"Huaiyue","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, Xinjiang University, Urumqi 830017, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7045-7597","authenticated-orcid":false,"given":"Rongchang","family":"Fu","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Xinjiang University, Urumqi 830017, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xu","family":"Zhu","sequence":"additional","affiliation":[{"name":"The Sixth Affiliated Hospital, Xinjiang Medical University, Urumqi 830002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,12,10]]},"reference":[{"key":"e_1_3_4_2_2","doi-asserted-by":"publisher","DOI":"10.1080\/13638490310001636808"},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11832-012-0457-4"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000197664.02098.09"},{"key":"e_1_3_4_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11832-012-0462-7"},{"key":"e_1_3_4_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-017-5421-z"},{"key":"e_1_3_4_7_2","unstructured":"Bin S. Design manufacture and biomechanical research of a 3D printed customized cervical intervertebral fusion cage[D]. Mphil Thesis. Chgo. Changchun: Jilin University 2023."},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2012.02.002"},{"key":"e_1_3_4_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000000778"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000001672"},{"key":"e_1_3_4_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-021-06748-w"},{"key":"e_1_3_4_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-016-5731-4"},{"key":"e_1_3_4_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e31826851a4"},{"key":"e_1_3_4_14_2","first-page":"1","article-title":"Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage[J]","volume":"30","author":"Dominik AA","year":"2021","unstructured":"Dominik AA, Ichiro O, Lisa O, et al. Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage[J]. European Spine Journal 2021; 30: 1\u20138.","journal-title":"European Spine Journal"},{"key":"e_1_3_4_15_2","article-title":"Risk factors of cage nonunion after anterior cervical discectomy and fusion[J]","volume":"99","author":"Bao R","year":"2020","unstructured":"Bao R, Wenshan G, Jilong A, et al. Risk factors of cage nonunion after anterior cervical discectomy and fusion[J]. Medicine 2020; 99: e19550.","journal-title":"Medicine"},{"key":"e_1_3_4_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2017.11.018"},{"key":"e_1_3_4_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2020.103982"},{"key":"e_1_3_4_18_2","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.900992"},{"key":"e_1_3_4_19_2","doi-asserted-by":"publisher","DOI":"10.31616\/asj.2020.0231"},{"key":"e_1_3_4_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2018.02.018"},{"key":"e_1_3_4_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s42242-020-00102-7"},{"key":"e_1_3_4_22_2","doi-asserted-by":"publisher","DOI":"10.1080\/10255840903208189"},{"key":"e_1_3_4_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1003-6326(11)61500-8"},{"key":"e_1_3_4_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(92)90290-H"},{"key":"e_1_3_4_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2014.02.020"},{"key":"e_1_3_4_26_2","first-page":"612","article-title":"Construction and analysis of a finite element model of human L4\u223c5 lumbar segment[J]","volume":"31","author":"Wentao Y","year":"2014","unstructured":"Wentao Y, Gaiping Z, Xinguo F, et al. Construction and analysis of a finite element model of human L4\u223c5 lumbar segment[J]. Journal of Biomedical Engineering 2014; 31: 612\u2013618.","journal-title":"Journal of Biomedical Engineering"},{"key":"e_1_3_4_27_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197254030-00005"},{"key":"e_1_3_4_28_2","first-page":"69","article-title":"On the use of biaxial properties in modeling annulus as a Holzapfel-Gasser-Ogden material[J]","volume":"3","author":"Shahraki EN","year":"2015","unstructured":"Shahraki EN, EFatemi A, Goel KV, et al. On the use of biaxial properties in modeling annulus as a Holzapfel-Gasser-Ogden material[J]. Frontiers in Bioengineering and Biotechnology 2015; 3: 69\u201378.","journal-title":"Frontiers in Bioengineering and Biotechnology"},{"key":"e_1_3_4_29_2","first-page":"135","volume-title":"Computational methods in bioengineering[M]","author":"Spilker RL","year":"1988","unstructured":"Spilker RL, Simon BR. Computational methods in bioengineering[M]. England: ASME, 1988, pp.135\u2013144."},{"key":"e_1_3_4_30_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197456040-00003"},{"key":"e_1_3_4_31_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-195739050-00014"},{"key":"e_1_3_4_32_2","article-title":"Porous interbody fusion cage design via topology optimization and biomechanical performance analysis[J]","volume":"26","author":"Nan L","year":"2022","unstructured":"Nan L, Yang Z, Qiaohong T, et al. Porous interbody fusion cage design via topology optimization and biomechanical performance analysis[J]. Computer Methods in Biomechanics and Biomedical Engineering 2022; 26: 11\u201310.","journal-title":"Computer Methods in Biomechanics and Biomedical Engineering"},{"key":"e_1_3_4_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.matpr.2021.10.112"},{"key":"e_1_3_4_34_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10409-023-23047-x"},{"key":"e_1_3_4_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2019.04.024"},{"key":"e_1_3_4_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.inat.2020.100918"},{"key":"e_1_3_4_37_2","doi-asserted-by":"publisher","DOI":"10.1142\/S0219519423500434"},{"key":"e_1_3_4_38_2","article-title":"Finite element analysis of lattice designed lumbar interbody cage based on the additive manufacturing[J]","volume":"237","author":"B\u00fclent B","year":"2023","unstructured":"B\u00fclent B, Akif MO, Erkan B, et al. Finite element analysis of lattice designed lumbar interbody cage based on the additive manufacturing[J]. Proceedings of the Institution of Mechanical Engineers. Part H. Journal of Engineering in Medicine 2023; 237: 9544119231184379-9544. DOI: https:\/\/doi.org\/10.1177\/09544119231184379.","journal-title":"Proceedings of the Institution of Mechanical Engineers. Part H. Journal of Engineering in Medicine"},{"key":"e_1_3_4_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2009.03.005"},{"key":"e_1_3_4_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2018.04.010"},{"key":"e_1_3_4_41_2","doi-asserted-by":"publisher","DOI":"10.1007\/s42242-021-00162-3"},{"key":"e_1_3_4_42_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.23445"},{"key":"e_1_3_4_43_2","doi-asserted-by":"publisher","DOI":"10.1021\/acsomega.2c02340"},{"key":"e_1_3_4_44_2","first-page":"18","article-title":"Research progress of surface\/interface interaction between Titanium Alloy implants and human tissue[J]","volume":"46","author":"Sen Y","year":"2017","unstructured":"Sen Y, Zhentao Y, Jinlong N, et al. Research progress of surface\/interface interaction between Titanium Alloy implants and human tissue[J]. Hot Working Technology 2017; 46: 18\u201322.","journal-title":"Hot Working Technology"},{"key":"e_1_3_4_45_2","first-page":"5559","article-title":"Bio-safety of 3D printed titanium and titanium alloys for medical application[J]","volume":"22","author":"Liping W","year":"2018","unstructured":"Liping W, Shanfang Z, Ruicheng L, et al. Bio-safety of 3D printed titanium and titanium alloys for medical application[J]. Chinese Journal of Tissue Engineering Research 2018; 22: 5559\u20135564.","journal-title":"Chinese Journal of Tissue Engineering Research"}],"container-title":["Bio-Medical Materials and Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09592989241303291","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09592989241303291","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09592989241303291","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:24:41Z","timestamp":1777382681000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09592989241303291"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,10]]},"references-count":44,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,3]]}},"alternative-id":["10.1177\/09592989241303291"],"URL":"https:\/\/doi.org\/10.1177\/09592989241303291","relation":{},"ISSN":["0959-2989","1878-3619"],"issn-type":[{"value":"0959-2989","type":"print"},{"value":"1878-3619","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,10]]}}}