{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T23:43:39Z","timestamp":1771717419942,"version":"3.50.1"},"reference-count":19,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2011,11,7]],"date-time":"2011-11-07T00:00:00Z","timestamp":1320624000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering"],"published-print":{"date-parts":[[2012,4]]},"abstract":"<jats:p> The present work aims at developing a methodology for designing a swash-plate axial-piston pump whose barrel kidneys are wider than the bridges separating the kidney ports on the plate. Besides reducing pressure ripples and avoiding cavitation for minimizing the fluid-borne noise, maximization of the pump discharge has also been considered in formulating an objective function to be minimized. A comprehensive mathematical model considering oil compressibility and inertia has been developed and implemented in MATLAB\/Simulink for dynamic simulation of the pump flow. The model has been found acceptable by observing a good match between its predictions of mean discharge and delivery pressure and available experimental results. A detailed parametric study has been performed and the optimum angles for the valve-plate pre-compression and the barrel kidneys have been obtained. <\/jats:p>","DOI":"10.1177\/0959651811426508","type":"journal-article","created":{"date-parts":[[2011,11,8]],"date-time":"2011-11-08T07:23:39Z","timestamp":1320737019000},"page":"451-465","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":26,"title":["Effects of flow inertia modelling and valve-plate geometry on swash-plate axial-piston pump performance"],"prefix":"10.1177","volume":"226","author":[{"given":"N P","family":"Mandal","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Jadavpur University, Kolkata, India"}]},{"given":"R","family":"Saha","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Jadavpur University, Kolkata, India"}]},{"given":"D","family":"Sanyal","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Jadavpur University, Kolkata, India"}]}],"member":"179","published-online":{"date-parts":[[2011,11,7]]},"reference":[{"key":"bibr1-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1299\/jsme1958.20.79"},{"key":"bibr2-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1299\/jsme1958.20.827"},{"key":"bibr3-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1115\/1.482452"},{"key":"bibr4-0959651811426508","unstructured":"Ivantysyn J., Ivantysynova M. Hydrostatics pumps and motors, edition 1, 2001, ch. 4, pp. 132\u2013133 (Akademia Books International, New Delhi)."},{"key":"bibr5-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsolstr.2005.03.028"},{"key":"bibr6-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1115\/1.1389311"},{"key":"bibr7-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1115\/1.1541632"},{"key":"bibr8-0959651811426508","first-page":"181","volume-title":"Proceedings of Tenth Aachen Colloquium on Fluid Power Technology","author":"Pettersson M."},{"key":"bibr9-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1243\/0959651001540519"},{"key":"bibr10-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1115\/1.4002058"},{"key":"bibr11-0959651811426508","unstructured":"Li Z. Condition monitoring of axial piston pump. MS Thesis, 2005, Department of Mechanical Engineering, University of Saskatchewan, Saskatoon (available from http:\/\/library2.usask.ca\/theses\/available\/etd-11252005-202705\/unrestricted\/Eric%20Lithesis%202005NovA.pdf)."},{"key":"bibr12-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1243\/09596518JSCE208"},{"key":"bibr13-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1243\/09596518JSCE580"},{"key":"bibr14-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1243\/PIME_PROC_1986_200_047_02"},{"key":"bibr15-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1631\/jzus.A0900417"},{"key":"bibr16-0959651811426508","unstructured":"Brennen C. E. Hydrodynamics of pumps, edition 1, 1994, ch. 5, p. 78 (Concepts ETI Inc. and Oxford University Press, New York)."},{"key":"bibr17-0959651811426508","unstructured":"Galal Rabie M. Fluid power engineering, edition 1, 2009, ch. 4, pp. 97\u201398 (McGraw Hill New York)."},{"key":"bibr18-0959651811426508","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9781139175241"},{"key":"bibr19-0959651811426508","unstructured":"Deb K. Optimization for engineering design, edition 1, 2006, ch. 4, p. 153 (Prentice-Hall of India Pvt Ltd, New Delhi)."}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0959651811426508","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0959651811426508","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0959651811426508","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,28]],"date-time":"2025-01-28T16:51:39Z","timestamp":1738083099000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0959651811426508"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,11,7]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,4]]}},"alternative-id":["10.1177\/0959651811426508"],"URL":"https:\/\/doi.org\/10.1177\/0959651811426508","relation":{},"ISSN":["0959-6518","2041-3041"],"issn-type":[{"value":"0959-6518","type":"print"},{"value":"2041-3041","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,11,7]]}}}