{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T15:04:58Z","timestamp":1781622298587,"version":"3.54.5"},"reference-count":28,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2020,7,20]],"date-time":"2020-07-20T00:00:00Z","timestamp":1595203200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61873057"],"award-info":[{"award-number":["61873057"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Jilin City Science and Technology Bureau","award":["201831727"],"award-info":[{"award-number":["201831727"]}]},{"name":"Jilin City Science and Technology Bureau","award":["201831731"],"award-info":[{"award-number":["201831731"]}]},{"DOI":"10.13039\/100007847","name":"Natural Science Foundation of Jilin Province","doi-asserted-by":"publisher","award":["20180520211JH"],"award-info":[{"award-number":["20180520211JH"]}],"id":[{"id":"10.13039\/100007847","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100010211","name":"Education Department of Jilin Province","doi-asserted-by":"publisher","award":["JJKH20200118KJ"],"award-info":[{"award-number":["JJKH20200118KJ"]}],"id":[{"id":"10.13039\/501100010211","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering"],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:p>The main purpose of this article is to study the sensor fault isolation for DC-DC converters, taking the single-ended primary industry converter as an example. To achieve the purpose of the research, we model the DC-DC converters as switched affine systems and design a bank of sliding mode observers for each corresponding sensor fault. By comparing the threshold with the residual estimation function produced by each sliding model observers, we can diagnose which sensor faults are occurring. Finally, three sensor faults are given as simulation examples to verify the feasibility of the proposed scheme.<\/jats:p>","DOI":"10.1177\/0959651820939694","type":"journal-article","created":{"date-parts":[[2020,7,20]],"date-time":"2020-07-20T05:46:47Z","timestamp":1595224007000},"page":"400-410","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["Sensor fault isolation for DC-DC converters via switched affine systems"],"prefix":"10.1177","volume":"235","author":[{"given":"Jian","family":"Li","sequence":"first","affiliation":[{"name":"Northeast Electric Power University, Jilin City, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunpeng","family":"Pan","sequence":"additional","affiliation":[{"name":"Northeast Electric Power University, Jilin City, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1355-6748","authenticated-orcid":false,"given":"Qingyu","family":"Su","sequence":"additional","affiliation":[{"name":"Northeast Electric Power University, Jilin City, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2020,7,20]]},"reference":[{"key":"bibr1-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2019.07.059"},{"key":"bibr2-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1007\/s40313-015-0168-4"},{"key":"bibr3-0959651820939694","first-page":"282","volume":"353","author":"Li J","year":"2019","journal-title":"Appl Math Comput"},{"key":"bibr4-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/j.nahs.2019.05.001"},{"key":"bibr5-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/37.793443"},{"key":"bibr6-0959651820939694","first-page":"1","volume":"99","author":"Long Y","year":"2019","journal-title":"IEEE Trans Syst Man Cybernet Syst"},{"key":"bibr7-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2017.08.021"},{"key":"bibr8-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2019.12.071"},{"key":"bibr9-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2019.2935685."},{"key":"bibr10-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2007.910627"},{"key":"bibr11-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1049\/iet-cta.2014.1004"},{"key":"bibr12-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1049\/iet-cta:20060408"},{"key":"bibr13-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1021\/ie801056y"},{"key":"bibr14-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/TCYB.2019.2901867"},{"key":"bibr15-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/0005-1098(90)90018-D"},{"key":"bibr16-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1049\/iet-cta.2011.0057"},{"key":"bibr17-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1049\/iet-pel.2013.0949"},{"key":"bibr18-0959651820939694","first-page":"36","volume":"312","author":"Ye D","year":"2017","journal-title":"Appl Math Comput"},{"issue":"1","key":"bibr19-0959651820939694","first-page":"84","volume":"7","author":"He J","year":"2009","journal-title":"J Dynam Contr"},{"key":"bibr20-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/S0005-1098(99)00079-5"},{"key":"bibr21-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/9.580881"},{"key":"bibr22-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/S0959-1524(00)00021-4"},{"key":"bibr23-0959651820939694","first-page":"1183","volume-title":"IEEE conference on decision and control and European control conference","author":"Trofino A"},{"key":"bibr24-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1002\/rnc.4672"},{"key":"bibr25-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/TCSI.2018.2857771"},{"key":"bibr26-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2019.2912780"},{"key":"bibr27-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2017.2789186"},{"key":"bibr28-0959651820939694","doi-asserted-by":"publisher","DOI":"10.1016\/j.sysconle.2014.02.007"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0959651820939694","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/0959651820939694","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/0959651820939694","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:39:31Z","timestamp":1777675171000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/0959651820939694"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,20]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["10.1177\/0959651820939694"],"URL":"https:\/\/doi.org\/10.1177\/0959651820939694","relation":{},"ISSN":["0959-6518","2041-3041"],"issn-type":[{"value":"0959-6518","type":"print"},{"value":"2041-3041","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,20]]}}}