{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T04:39:16Z","timestamp":1778733556675,"version":"3.51.4"},"reference-count":30,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T00:00:00Z","timestamp":1727913600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["62073139, 62333006"],"award-info":[{"award-number":["62073139, 62333006"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:p>This work deal with the sliding mode control (SMC) issue for T-S fuzzy systems under unreliable communication environment. As a way to alleviate the transmission burden in communication networks, the round-robin protocol (RRP) is utilized for information exchange between sensors and controller. The transmitted state components via scheduling protocol may be subject to network-induced disturbances and random denial-of-service (DoS) attacks. To attenuate the adverse factors, a sliding mode controller depending on the fuzzy rules is constructed, and by employing the membership-function-dependent (MFD) technique, appropriate sufficient conditions are derived to ensure both the stochastic stability and the reachability. Finally, simulation results are presented to prove the proposed SMC strategy.<\/jats:p>","DOI":"10.1177\/09596518241272914","type":"journal-article","created":{"date-parts":[[2024,10,4]],"date-time":"2024-10-04T02:00:17Z","timestamp":1728007217000},"page":"260-271","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Sliding mode resilient control for T-S fuzzy systems under unreliable communication environment: Round-robin scheduling strategy"],"prefix":"10.1177","volume":"239","author":[{"given":"Yibang","family":"Wu","sequence":"first","affiliation":[{"name":"Key Laboratory of Smart Manufacturing in Energy Chemical Process (East China University of Science and Technology), Ministry of Education, Shanghai, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3010-1879","authenticated-orcid":false,"given":"Yugang","family":"Niu","sequence":"additional","affiliation":[{"name":"Key Laboratory of Smart Manufacturing in Energy Chemical Process (East China University of Science and Technology), Ministry of Education, Shanghai, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yekai","family":"Yang","sequence":"additional","affiliation":[{"name":"College of Information Science and Technology, Donghua University, Shanghai, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2024,10,3]]},"reference":[{"key":"bibr1-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2006.883415"},{"key":"bibr2-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2019.2906040"},{"key":"bibr3-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1177\/0959651818774983"},{"key":"bibr4-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2021.3076512"},{"key":"bibr5-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TSMCB.2005.850181"},{"key":"bibr6-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfranklin.2020.06.018"},{"key":"bibr7-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1177\/09596518221118179"},{"key":"bibr8-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1177\/09596518211055358"},{"key":"bibr9-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1177\/09596518221144796"},{"key":"bibr10-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2022.12.118"},{"key":"bibr11-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.fss.2023.02.002"},{"key":"bibr12-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2021.3071360"},{"key":"bibr13-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.isatra.2016.09.026"},{"key":"bibr14-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2023.110982"},{"key":"bibr15-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2022.12.006"},{"key":"bibr16-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/COMST.2014.2320071"},{"key":"bibr17-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2019.2919513"},{"key":"bibr18-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2021.3049306"},{"key":"bibr19-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2022.3165379"},{"key":"bibr20-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2021.3069329"},{"key":"bibr21-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2019.2956714"},{"key":"bibr22-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2016.2539259"},{"key":"bibr23-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfranklin.2021.04.014"},{"key":"bibr24-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TCYB.2020.2972384"},{"key":"bibr25-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2018.12.091"},{"key":"bibr26-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2022.3193805"},{"key":"bibr27-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TFUZZ.2023.3239930"},{"key":"bibr28-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TNNLS.2021.3137426"},{"key":"bibr29-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TCYB.2018.2885653"},{"key":"bibr30-09596518241272914","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2022.3219919"}],"container-title":["Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09596518241272914","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/09596518241272914","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/09596518241272914","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:46:57Z","timestamp":1777675617000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/09596518241272914"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,3]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["10.1177\/09596518241272914"],"URL":"https:\/\/doi.org\/10.1177\/09596518241272914","relation":{},"ISSN":["0959-6518","2041-3041"],"issn-type":[{"value":"0959-6518","type":"print"},{"value":"2041-3041","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,3]]}}}