{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T21:15:12Z","timestamp":1777929312744,"version":"3.51.4"},"reference-count":20,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Orthop Surg (Hong Kong)"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>: Titanium volar locking plates are widely used in distal radius fractures (DFRs) fixation, but their induction of radiographic shielding hinders fracture assessment. Carbon fiber-reinforced polyether ether ketone (CFR-PEEK) plates are radiolucent and biomechanically comparable to titanium, potentially improving intraoperative visualization and postoperative follow-up. This study aims to compare clinical and radiographic outcomes between CFR-PEEK and titanium plates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This retrospective study included 39 patients with DRFs treated with either CFR-PEEK (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 19) or titanium plates (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 20) between August 2018 and June 2019. Intraoperative and postoperative parameters were compared between the two groups. The Wilcoxon rank sum test and Fisher\u2019s exact test were applied for statistical analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Satisfactory fracture reduction without implant-related complications was achieved in both groups. At 12\u00a0months, wrist range of motion and radiographic alignment did not significantly differ between the groups (both\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &gt; 0.05), and Disabilities of the Arm, Shoulder and Hand (DASH) scores were comparable between the groups (11.8 \u00b1 7.0 vs 11.9 \u00b1 4.6,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &gt; 0.05). Notably, intraoperative CFR-PEEK plates significantly reduced the operative time compared with titanium plates (64.16 \u00b1 15.24\u00a0min vs 78.4 \u00b1 20.63\u00a0min,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.0387). The implant removal rates did not differ between the groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CFR-PEEK volar locking plates demonstrated clinical and radiographic outcomes comparable to titanium plates, with added advantages of radiolucency and surgical efficiency, including a significantly shorter operative time. These findings identify CFR-PEEK plates as a safe and effective alternative in DRFs fixation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/10225536261434069","type":"journal-article","created":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T20:11:33Z","timestamp":1773951093000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of radiolucent CFR-PEEK and titanium volar locking plates in distal radius fracture fixation"],"prefix":"10.1177","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-9828-0067","authenticated-orcid":false,"given":"Tse-Pu","family":"Huang","sequence":"first","affiliation":[{"name":"National Defense Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhi-Hong","family":"Zheng","sequence":"additional","affiliation":[{"name":"National Defense Medical University"},{"name":"National Defense Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chia-Yuan","family":"Chen","sequence":"additional","affiliation":[{"name":"National Defense Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui-Sen","family":"Tseng","sequence":"additional","affiliation":[{"name":"National Defense Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pei-Hung","family":"Shen","sequence":"additional","affiliation":[{"name":"National Defense Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kun-Yi","family":"Lin","sequence":"additional","affiliation":[{"name":"National Defense Medical University"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2026,3,19]]},"reference":[{"key":"e_1_3_6_2_2","doi-asserted-by":"publisher","DOI":"10.36149\/0390-5276-224"},{"key":"e_1_3_6_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-021-01778-x"},{"key":"e_1_3_6_4_2","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-023-00724-4"},{"key":"e_1_3_6_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-024-04131-1"},{"key":"e_1_3_6_6_2","doi-asserted-by":"publisher","DOI":"10.52965\/001c.28362"},{"key":"e_1_3_6_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2012.09.013"},{"key":"e_1_3_6_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/1753193413475962"},{"key":"e_1_3_6_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.22251"},{"key":"e_1_3_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2013.03.018"},{"key":"e_1_3_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2016.10.015"},{"key":"e_1_3_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001763"},{"key":"e_1_3_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(17)30653-8"},{"key":"e_1_3_6_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-011-9438-2"},{"key":"e_1_3_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.10.018"},{"key":"e_1_3_6_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11552-014-9666-2"},{"issue":"2","key":"e_1_3_6_17_2","first-page":"308","article-title":"Measurement of ulnar variance and radial inclination on X-rays of healed distal radius fractures: with the axis of the distal radius or ulna?","volume":"81","author":"Thuysbaert G","year":"2015","unstructured":"Thuysbaert G, Ringburg A, Petronilia S, et al. Measurement of ulnar variance and radial inclination on X-rays of healed distal radius fractures: with the axis of the distal radius or ulna? Acta Orthop Belg 2015; 81(2): 308\u2013314.","journal-title":"Acta Orthop Belg"},{"key":"e_1_3_6_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/0300060513476438"},{"key":"e_1_3_6_19_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13063-017-2409-2"},{"key":"e_1_3_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.07.013"},{"key":"e_1_3_6_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-020-02701-7"}],"container-title":["Journal of Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10225536261434069","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/10225536261434069","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10225536261434069","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T23:33:30Z","timestamp":1777678410000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/10225536261434069"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1177\/10225536261434069"],"URL":"https:\/\/doi.org\/10.1177\/10225536261434069","relation":{},"ISSN":["1022-5536","2309-4990"],"issn-type":[{"value":"1022-5536","type":"print"},{"value":"2309-4990","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"article-number":"10225536261434069"}}