{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T20:27:13Z","timestamp":1787948833586,"version":"build-2784847793"},"reference-count":41,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["NeuroRehabilitation"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>With the development of modern biomedical engineering, bio-signal feedback-based robots, such as electromyography (EMG)-based and brain-computer interface (BCI)-based rehabilitation robot, have emerged beyond conventional designs. However, their comparative effectiveness for improving upper limb function in stroke patients remains unassessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the comparative effectiveness and ranking of the conventional rehabilitation robot and bio-signal feedback-based rehabilitation robot in improving upper limb function in stroke patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>PubMed, EMBASE, Cochrane Library, CINAHL, PEDro, EI, IEEEXplore, ClinicalTrials.gov, ICTRP, and ISRCTN Registry were searched for randomized controlled trials (RCTs) from their inception to December 25, 2024. The risk of bias was assessed using the Cochrane Risk of Bias tool (RoB 2.0) and evidence certainty with the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. Network meta-analyses were performed using a random-effects model within a frequentist framework.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>59 RCTs with 3,387 participants were included. Based on the surface under the cumulative ranking curve (SUCRA), the BCI-based rehabilitation robot demonstrated the highest overall effects (SUCRA: 99.9%), short-term effects (SUCRA: 99.4%), and long-term effects (SUCRA: 85.1%), though its long-term effects were not significant (mean difference: 2.21; 95% confidence interval: \u22120.79, 5.21). The EMG-based rehabilitation robot outperformed the conventional rehabilitation robot in short-term interventions (SUCRA: 59.8% vs. 40.3%), but it did not have the same advantage in long-term interventions (SUCRA: 27.1% vs. 66.8%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The BCI-based rehabilitation robot might be the best choice for improving upper limb function in stroke patients. Future studies should focus on the intervention time for the EMG-based rehabilitation robot.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/10538135251366668","type":"journal-article","created":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T14:24:46Z","timestamp":1761834286000},"page":"169-180","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Efficacy of the Conventional Rehabilitation Robot and bio-Signal Feedback-Based Rehabilitation Robot on Upper-Limb Function in Patients with Stroke: A Systematic Review and Network Meta-Analysis"],"prefix":"10.1177","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4995-3884","authenticated-orcid":false,"given":"Lixue","family":"Zhou","sequence":"first","affiliation":[{"name":"School of Nursing, Capital Medical University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2165-9424","authenticated-orcid":false,"given":"Bohan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Centre for Smart Health, School of Nursing, The Hong Kong Polytechnic University, Kowloon, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4566-683X","authenticated-orcid":false,"given":"Ruifu","family":"Kang","sequence":"additional","affiliation":[{"name":"School of Nursing, Capital Medical University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1295-4245","authenticated-orcid":false,"given":"Yanling","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Nursing, Capital Medical University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7059-0929","authenticated-orcid":false,"given":"Jing","family":"Qin","sequence":"additional","affiliation":[{"name":"Centre for Smart Health, School of Nursing, The Hong Kong Polytechnic University, Kowloon, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5657-2863","authenticated-orcid":false,"given":"Qian","family":"Xiao","sequence":"additional","affiliation":[{"name":"School of Nursing, Capital Medical University, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1966-6139","authenticated-orcid":false,"given":"Vivian","family":"Hui","sequence":"additional","affiliation":[{"name":"Centre for Smart Health, School of Nursing, The Hong Kong Polytechnic University, Kowloon, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,9,4]]},"reference":[{"key":"e_1_3_3_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/1545968321997769"},{"issue":"1","key":"e_1_3_3_3_1","first-page":"30","article-title":"Brain-computer interface-based robotic end effector system for wrist and hand rehabilitation\u202f: Results of a three-armed randomized controlled trial for chronic stroke","volume":"7","author":"Ang K. K.","year":"2014","unstructured":"Ang K. K., Guan C., Phua K. S., Wang C., Zhou L., Tang K. Y., Joseph G.J.E., Kuah C.W.K., Chua K.S.G. (2014). Brain-computer interface-based robotic end effector system for wrist and hand rehabilitation\u202f: Results of a three-armed randomized controlled trial for chronic stroke. Frontiers in Neuroengineering, 7(1), 30. https:\/\/doi.org\/10.3389\/fneng.2014.00030","journal-title":"Frontiers in Neuroengineering"},{"key":"e_1_3_3_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-021-00820-8"},{"key":"e_1_3_3_5_1","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2010.04.0062"},{"key":"e_1_3_3_6_1","volume-title":"Cochrane Handbook for systematic reviews of interventions","author":"Chandler J.","year":"2019","unstructured":"Chandler J., Cumpston M., Li T., Page M. J., Welch V. A. (2019). Cochrane Handbook for systematic reviews of interventions (2nd Ed.). Wiley-Blackwell.","edition":"2"},{"key":"e_1_3_3_7_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-021-00961-w"},{"key":"e_1_3_3_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.122.041480"},{"key":"e_1_3_3_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/brb3.1742"},{"key":"e_1_3_3_10_1","doi-asserted-by":"publisher","DOI":"10.3390\/s21206863"},{"key":"e_1_3_3_11_1","doi-asserted-by":"publisher","DOI":"10.1113\/JP279845"},{"key":"e_1_3_3_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/sim.8383"},{"key":"e_1_3_3_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/1545968317740634"},{"issue":"1","key":"e_1_3_3_14_1","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1109\/TNSRE.2022.3185262","article-title":"SSVEP-based brain computer interface controlled soft robotic glove for post-stroke hand function rehabilitation","volume":"30","author":"Guo N.","year":"2022","unstructured":"Guo N., Wang X.J., Duanmu D.H., Huang X., Li X.D., Fan Y.L., Li H.L., Liu Y.Q., Yeung E.H.K., To M.K.T., Gu J.X., Wan F., , & Hu Y. (2022). SSVEP-based brain computer interface controlled soft robotic glove for post-stroke hand function rehabilitation. IEEE transactions on Neural Systems and Rehabilitation Engineering\u202f: A Publication of the IEEE Engineering in Medicine and Biology Society, 30(1), 1737\u20131744. https:\/\/doi.org\/10.1109\/TNSRE.2022.3185262","journal-title":"IEEE transactions on Neural Systems and Rehabilitation Engineering\u202f: A Publication of the IEEE Engineering in Medicine and Biology Society"},{"key":"e_1_3_3_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/JPO.0000000000000277"},{"issue":"15","key":"e_1_3_3_16_1","first-page":"3866","article-title":"Research progress on the application of upper limb rehabilitation robot in motor dysfunction after stroke","volume":"42","author":"He Y.","year":"2022","unstructured":"He Y., Song J., Wu J. (2022). Research progress on the application of upper limb rehabilitation robot in motor dysfunction after stroke. Journal of Gerontology, 42(15), 3866\u20133870. https:\/\/doi.org\/10.3969\/j.issn.1005-9202.2022.15.064","journal-title":"Journal of Gerontology"},{"key":"e_1_3_3_17_1","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2023.1172958"},{"key":"e_1_3_3_18_1","doi-asserted-by":"publisher","DOI":"10.7326\/M14-2385"},{"key":"e_1_3_3_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1747-4949.2012.00967.x"},{"key":"e_1_3_3_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(11)60325-5"},{"key":"e_1_3_3_21_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40708-023-00199-3"},{"key":"e_1_3_3_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2014.2364273"},{"key":"e_1_3_3_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/jrsm.1480"},{"key":"e_1_3_3_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apmr.2014.10.022"},{"key":"e_1_3_3_25_1","doi-asserted-by":"publisher","DOI":"10.2340\/16501977-2229"},{"key":"e_1_3_3_26_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-020-00715-0"},{"key":"e_1_3_3_27_1","doi-asserted-by":"publisher","DOI":"10.3389\/fnhum.2022.897870"},{"key":"e_1_3_3_28_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1003082"},{"key":"e_1_3_3_29_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-019-0563-3"},{"key":"e_1_3_3_30_1","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/ac0b52"},{"key":"e_1_3_3_31_1","doi-asserted-by":"publisher","DOI":"10.1080\/17483107.2022.2060354"},{"key":"e_1_3_3_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-018-0383-x"},{"key":"e_1_3_3_33_1","doi-asserted-by":"publisher","DOI":"10.1177\/1545968319827573"},{"key":"e_1_3_3_34_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0000000000012781"},{"key":"e_1_3_3_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2016.04.004"},{"issue":"3","key":"e_1_3_3_36_1","article-title":"Rob 2\u202f: A revised tool for assessing risk of bias in randomised trials","volume":"366","author":"Sterne J. A. C.","year":"2019","unstructured":"Sterne J. A. C., Savovi\u0107 J., Page M. J., Elbers R. G., Blencowe N. S., Boutron I.,Cates C.J., Cheng H.Y., Corbett M.S., Eldridge S.M., Emberson J.R., Hern\u00e1n M.A., Hopewell S., Hr\u00f3bjartsson A., Junqueira D.R., J\u00fcni P., Kirkham J.J., Lasserson T., Li T., \u2026 Higgins J. P. T. (2019). Rob 2\u202f: A revised tool for assessing risk of bias in randomised trials. BMJ, 366(3), l4898. https:\/\/doi.org\/10.1136\/bmj.l4898","journal-title":"BMJ"},{"key":"e_1_3_3_37_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000757"},{"key":"e_1_3_3_38_1","doi-asserted-by":"publisher","DOI":"10.1161\/STR.0000000000000098"},{"issue":"1","key":"e_1_3_3_39_1","first-page":"151","article-title":"Review of comprehensive intervention by hand rehabilitation robot after stroke","volume":"36","author":"Wu H.","unstructured":"Wu H., Li L., Li L., Liu T., Wang J. (2019a). Review of comprehensive intervention by hand rehabilitation robot after stroke. Journal of Biomedical Engi-Neering, 36(1), 151\u2013156. https:\/\/doi.org\/10.7507\/1001-5515.201711024","journal-title":"Journal of Biomedical Engi-Neering"},{"key":"e_1_3_3_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(18)30500-3"},{"key":"e_1_3_3_41_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12035-020-02021-1"},{"key":"e_1_3_3_42_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12082950"}],"container-title":["NeuroRehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10538135251366668","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/10538135251366668","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10538135251366668","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T00:00:53Z","timestamp":1777680053000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/10538135251366668"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":41,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1177\/10538135251366668"],"URL":"https:\/\/doi.org\/10.1177\/10538135251366668","relation":{},"ISSN":["1053-8135","1878-6448"],"issn-type":[{"value":"1053-8135","type":"print"},{"value":"1878-6448","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9]]}}}