{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T02:00:04Z","timestamp":1783476004070,"version":"3.55.0"},"reference-count":35,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T00:00:00Z","timestamp":1768780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Changwon Medical-Bio Advanced Device Manufacturing Industry Promotion Project 2023"},{"name":"Ministry of Education(MOE) and the","award":["2025-RISE-11-004-02"],"award-info":[{"award-number":["2025-RISE-11-004-02"]}]},{"name":"National Research Foundation of Korea (NRF) grant funded by the Korean government","award":["2022R1F1A1068815"],"award-info":[{"award-number":["2022R1F1A1068815"]}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["NeuroRehabilitation"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Over-ground walking assistance robots are increasingly being used in stroke rehabilitation; however, their clinical effects remain underexplored.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>We investigated the immediate effects, in a single-session design, of an over-ground walking assistance robot with Mecanum wheels (OWAR-MW) on gait and lower limb muscle activity in stroke.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Thirty patients with stroke (age: 67.3 years; time since stroke: 12.4 months) participated in a repeated-measures study. Each performed a 20\u2005m straight-line walk using Andago\n                      <jats:sup>\u00ae<\/jats:sup>\n                      and OWAR-MW in random order. Gait was measured using a triaxial accelerometer, and surface electromyography recorded muscle activities of the rectus femoris, biceps femoris, tibialis anterior, gastrocnemius, and gluteus medius on the paretic side.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No significant differences in gait were observed between robots (all\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&gt;\u2009.05). However, the OWAR-MW elicited greater muscle activation than the Andago\n                      <jats:sup>\u00ae<\/jats:sup>\n                      . In particular, the gluteus medius (stance: 274.06 vs. 213.00%RVC,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u2009.048, d\u2009=\u2009\u22120.38, 95% CI [\u22120.745, \u22120.004]; swing: 354.04 vs. 199.32%RVC,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u2009.002, d\u2009=\u2009\u22120.64, 95% CI [\u22121.026, \u22120.239]) and tibialis anterior (stance: 594.23 vs. 423.70%RVC,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u2009.046, d\u2009=\u2009\u22120.38, 95% CI [\u22120.749, \u22120.007]; swing: 657.60 vs. 440.94%RVC,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u2009.027, d\u2009=\u2009\u22120.43, 95% CI [\u22120.796, \u22120.048]) showed significantly higher activation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      The OWAR-MW provided mobility assistance comparable to the Andago\n                      <jats:sup>\u00ae<\/jats:sup>\n                      , while promoting greater lower limb muscle activation. However, these findings represent single-session physiological responses and should be interpreted as exploratory. Further research involving multi-session training and long-term functional outcomes is required to determine the clinical applicability.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/10538135251413669","type":"journal-article","created":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T17:56:11Z","timestamp":1768845371000},"page":"239-250","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Immediate Effect of an Over-Ground Walking Assistance Robot with Mecanum Wheels on Lower Limb Muscle Activity and Gait Ability in Stroke: A Single-Session Study"],"prefix":"10.1177","volume":"58","author":[{"given":"Eun Pyeong","family":"Choi","sequence":"first","affiliation":[{"name":"Department of Physical Therapy, Korea National University of Transportation, Jeungpyeong-gun, Chungcheongbuk-do, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6248-1768","authenticated-orcid":false,"given":"Ki Hun","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Physical Therapy, Korea National University of Transportation, Jeungpyeong-gun, Chungcheongbuk-do, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,1,19]]},"reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jare.2015.01.011"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm14072309"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmrj.2013.12.017"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2009.07.004"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2017.10.048"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.3390\/app15094773"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.23736\/S1973-9087.21.06887-8"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1212\/01.wnl.0000202600.72018.39"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-025-01551-w"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1080\/09593985.2022.2162834"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.3390\/biomimetics10010036"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.3200\/JMBR.36.2.212-224"},{"key":"e_1_3_2_14_1","unstructured":"Hocoma. Andago\u2013Robotic Gait Training. Available at: https:\/\/www.hocoma.com\/solutions\/andago\/. Accessed August 18 2025."},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.3390\/app15105294"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2023.05.022"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/22130683251342184"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apmr.2023.03.006"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-022-01076-6"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-020-0641-6"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.3389\/fnsys.2019.00074"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.15761\/PRR.1000128"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joca.2020.08.009"},{"key":"e_1_3_2_24_1","article-title":"AssistOn-Gait: An overground gait trainer with an active pelvis-hip exoskeleton","volume":"2015","author":"Munawar H.","year":"2015","unstructured":"Munawar H., Yalcin M., Patoglu V. (2015). AssistOn-Gait: An overground gait trainer with an active pelvis-hip exoskeleton. In Proceedings of the 2015 IEEE International Conference on Rehabilitation Robotics (ICORR), 594-599. IEEE. https:\/\/doi.org\/10.1109\/ICORR.2015.7281265","journal-title":"In Proceedings of the"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2009.10.014"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.2522\/ptj.20130046"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2025.3552192"},{"issue":"4","key":"e_1_3_2_28_1","first-page":"172","article-title":"Use of force platform variables to quantify the effects of chiropractic manipulation on gait symmetry","volume":"10","author":"Robinson R.","year":"1987","unstructured":"Robinson R., Herzog W., Nigg B. M. (1987). Use of force platform variables to quantify the effects of chiropractic manipulation on gait symmetry. Journal of Manipulative and Physiological Therapeutics, 10(4), 172\u2013176.","journal-title":"Journal of Manipulative and Physiological Therapeutics"},{"key":"e_1_3_2_29_1","doi-asserted-by":"publisher","DOI":"10.36413\/pjahs.0401.008"},{"key":"e_1_3_2_30_1","volume-title":"Standards for surface electromyography: The European project Surface EMG for non-invasive assessment of muscles (SENIAM)","author":"Stegeman D. F.","year":"2007","unstructured":"Stegeman D. F., Hermens H. J. (2007). Standards for surface electromyography: The European project Surface EMG for non-invasive assessment of muscles (SENIAM). Roessingh Research and Development."},{"key":"e_1_3_2_31_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-022-01003-9"},{"key":"e_1_3_2_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apmr.2017.09.117"},{"key":"e_1_3_2_33_1","doi-asserted-by":"publisher","DOI":"10.3390\/s19214773"},{"key":"e_1_3_2_34_1","doi-asserted-by":"publisher","DOI":"10.1161\/STR.0000000000000098"},{"issue":"15","key":"e_1_3_2_35_1","first-page":"1","article-title":"Current developments of robotic hip exoskeleton toward sensing, decision, and actuation: A review","volume":"3","author":"Yang C.","year":"2022","unstructured":"Yang C., Yu L., Xu L., Yan Z., Hu D., Zhang S., Yang W. (2022). Current developments of robotic hip exoskeleton toward sensing, decision, and actuation: A review. Wearable Technologies, 3, e15, 1\u201327. https:\/\/doi.org\/10.1017\/wtc.2022.11","journal-title":"Wearable Technologies"},{"issue":"1","key":"e_1_3_2_36_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2017\/3731802","article-title":"Robotics in lower-limb rehabilitation after stroke","volume":"2017","author":"Zhang X.","year":"2017","unstructured":"Zhang X., Yue Z., Wang J. (2017). Robotics in lower-limb rehabilitation after stroke. Behavioural Neurology, 2017(1), 1\u201313. https:\/\/doi.org\/10.1155\/2017\/3731802","journal-title":"Behavioural Neurology"}],"container-title":["NeuroRehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10538135251413669","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/10538135251413669","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10538135251413669","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T00:01:12Z","timestamp":1777680072000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/10538135251413669"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,19]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["10.1177\/10538135251413669"],"URL":"https:\/\/doi.org\/10.1177\/10538135251413669","relation":{},"ISSN":["1053-8135","1878-6448"],"issn-type":[{"value":"1053-8135","type":"print"},{"value":"1878-6448","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,19]]}}}