{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:12:29Z","timestamp":1777612349920,"version":"3.51.4"},"reference-count":30,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T00:00:00Z","timestamp":1516320000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Foot Ankle Int."],"published-print":{"date-parts":[[2018,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Indirect screw fixation of the sustentaculum tali in the lateral-medial direction can be challenging due to the complex calcaneal anatomy. A novel 2-dimensional (2D) projection-based software application detects Kirschner wires (K-wires) and visualizes their intended direction as a colored trajectory. The aim of this prospectively randomized cadaver study was to investigate whether the software would facilitate the indirect K-wire placement in the sustentaculum tali.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In 20 cadaver foot specimens, K-wires were placed indirectly in the sustentaculum tali by an experienced and an inexperienced surgeon, with and without using the application. Number of placement attempts, duration of procedure, fluoroscopy time, and number of individual fluoroscopy images were recorded. Each wire\u2019s position was analyzed in a 3-dimensional (3D) C-arm scan by an experienced blinded investigator.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Use of the software by the inexperienced surgeon significantly reduced the number of placement attempts from 3.2 to 1.2 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .006). The application also reduced operating time, from 273 s to 199 s (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .15), and fluoroscopy time, from 41 s to 29 s (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .15). Using the software, the experienced surgeon had a longer operating time (139 s to 183 s;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .30), longer fluoroscopy time (5.6 s to 9.2 s;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .17), and more individual fluoroscopy images (11.6 to 14.8;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .30). Wire position did not show significant differences in both cases.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>During indirect K-wire placement in the sustentaculum tali, the software appeared to be a useful tool for the inexperienced surgeon. In our chosen study setting, the experienced surgeon did not benefit from the software.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>Possible indications for the software would be fractures of the proximal femur, sacrum, sacroiliac instabilities, vertebral bodies, scaphoid, Lisfranc joint, talus and calcaneus.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1071100717746618","type":"journal-article","created":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T05:40:48Z","timestamp":1516340448000},"page":"485-492","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":5,"title":["Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms: Cadaveric Study"],"prefix":"10.1177","volume":"39","author":[{"given":"Benedict","family":"Swartman","sequence":"first","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk","family":"Frere","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wei","sequence":"additional","affiliation":[{"name":"Siemens Healthcare, Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc","family":"Schnetzke","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephan","family":"Grechenig","sequence":"additional","affiliation":[{"name":"Department of Trauma Surgery, Regensburg University, Regensburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amir","family":"Matityahu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University of California, San Francisco, san Francisco, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nils","family":"Beisemann","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Holger","family":"Keil","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jochen","family":"Franke","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0730-4782","authenticated-orcid":false,"given":"Paul Alfred","family":"Gr\u00fctzner","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sven Yves","family":"Vetter","sequence":"additional","affiliation":[{"name":"BG-Klinik Ludwigshafen, Clinic for Trauma Surgery and Orthopaedics, Trauma Surgery Clinic at Heidelberg University, Ludwigshafen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,1,19]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-013-2181-1."},{"issue":"21","key":"e_1_3_2_3_2","first-page":"2989","article-title":"Learning curve of computer-assisted navigation system in spine surgery","volume":"123","author":"Bai YS","year":"2010","unstructured":"Bai YS, Zhang Y, Chen ZQ, et al. Learning curve of computer-assisted navigation system in spine surgery. Chin Med J. 2010;123(21):2989-2994.","journal-title":"Chin Med J"},{"issue":"5","key":"e_1_3_2_4_2","first-page":"360","article-title":"Displaced intra-articular calcaneal fractures","volume":"19","author":"Bajammal S","year":"2005","unstructured":"Bajammal S, Tornetta PIII, Sanders D, Bhandari M. Displaced intra-articular calcaneal fractures. J Orthop Trauma. 2005;19(5):360-364.","journal-title":"J Orthop Trauma"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2014.08.021."},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.2106\/jbjs.e.00166."},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2014.01.017."},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3113\/fai.2009.1037."},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2016.04.003."},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.2106\/jbjs.g.00513."},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3113\/fai.2012.0079."},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.2106\/jbjs.m.00330."},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2012.03.011."},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.231."},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2004.05.008."},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3109\/10929080701300310."},{"issue":"421","key":"e_1_3_2_17_2","first-page":"70","article-title":"Image guidance: fluoroscopic navigation","volume":"2004","author":"Kahler DM.","unstructured":"Kahler DM. Image guidance: fluoroscopic navigation. Clin Orthop Relat Res. 2004(421):70-76.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2013.02.008."},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1476."},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.92b10.24594."},{"issue":"22","key":"e_1_3_2_21_2","first-page":"4220","article-title":"Minimally invasive manipulative reduction with poking k-wire fixation in the treatment of various types of calcaneal fractures","volume":"19","author":"Lu B","year":"2015","unstructured":"Lu B, Liu P, Wang Y, et al. Minimally invasive manipulative reduction with poking k-wire fixation in the treatment of various types of calcaneal fractures. Eur Rev Med Pharmacol Sci. 2015;19(22):4220-4226.","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-009-0816-z."},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20110124-05."},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(05)70202-9"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.08.019"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2017.07.022."},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0940-9602(11)80346-8"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200105000-00007"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1177\/107110070402501007"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.10.027."},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2014.03.018."}],"container-title":["Foot &amp; Ankle International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1071100717746618","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1071100717746618","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1071100717746618","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T21:22:42Z","timestamp":1777411362000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1071100717746618"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,19]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["10.1177\/1071100717746618"],"URL":"https:\/\/doi.org\/10.1177\/1071100717746618","relation":{},"ISSN":["1071-1007","1944-7876"],"issn-type":[{"value":"1071-1007","type":"print"},{"value":"1944-7876","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,19]]}}}