{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,8]],"date-time":"2026-11-08T11:24:18Z","timestamp":1794137058040,"version":"4.8.0"},"reference-count":22,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2025,6,28]],"date-time":"2025-06-28T00:00:00Z","timestamp":1751068800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/100017847","name":"Medline Industries","doi-asserted-by":"publisher","award":["USA-000138"],"award-info":[{"award-number":["USA-000138"]}],"id":[{"id":"10.13039\/100017847","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Foot Ankle Int."],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Metatarsophalangeal (MTP) arthrodesis is the gold standard for treatment of end-stage degeneration or severe hallux valgus deformities. Traditional fixation uses stainless steel or titanium plates, often with a crossing screw. Nitinol, a superelastic nickel-titanium alloy, offers dynamic compression. Nevertheless, it is unknown how nitinol implantation in the context of first-MTP arthrodesis performs biomechanically. We hypothesized that nitinol constructs would demonstrate biomechanical performance comparable or superior to a traditional plate-and-screw construct.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Twelve pairs of cadaveric metatarsophalangeal joints were organized into 3 groups according to a balanced incomplete block design: (1) a traditional titanium plate and cross-screw (PS) construct, (2) a nitinol staple and cross screw (NSS) construct, and (3) a proprietary nitinol hybrid screw (NHS) construct. The PS construct consisted of a plate with a compression cross screw; the NSS construct consisted of a nitinol staple with a compression cross screw; and the NHS construct consisted of a hybrid nitinol staple with a compression cross screw. Each specimen was cyclically loaded over 100 cycles at 1\u2009Hz from 20 to 90\u2009N followed by failure testing. A high-definition camera recorded gapping. Failure load, deflection, and stiffness were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Compared with the PS construct, both nitinol constructs (NSS and NHS) demonstrated significantly higher failure loads (NSS: 196\u2009\u00b1\u2009101\u2009N,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.011; NHS: 161\u2009\u00b1\u200945\u2009N,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.045), greater stiffness (NSS: 33\u2009\u00b1\u200915\u2009N\/mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.012; NHS: 29\u2009\u00b1\u200912\u2009N\/mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.042), reduced deflection after cyclic loading (NSS: 6\u2009\u00b1\u20093\u2009mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.047; NHS: 7\u2009\u00b1\u20093\u2009mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.048), and decreased gapping at failure (NSS: 1\u2009\u00b1\u20091\u2009mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.003; NHS: 2\u2009\u00b1\u20091\u2009mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.008). No significant differences were observed between NSS and NHS.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Nitinol constructs for MTP arthrodesis demonstrated superior mechanical performance compared with a traditional plate-and-screw construct, with higher failure load and stiffness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance:<\/jats:title>\n                    <jats:p>These results support the growing use of nitinol for joint fusion, highlighting its potential to improve load to failure and reduce displacement under cyclic loading.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/10711007251341886","type":"journal-article","created":{"date-parts":[[2025,6,28]],"date-time":"2025-06-28T09:59:28Z","timestamp":1751104768000},"page":"895-902","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical Comparison Between Fixation Techniques for First-Metatarsophalangeal Joint Arthrodesis"],"prefix":"10.1177","volume":"46","author":[{"given":"Chase M.","family":"Romere","sequence":"first","affiliation":[{"name":"The Steadman Clinic, Vail, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason P.","family":"Sidrak","sequence":"additional","affiliation":[{"name":"Steadman Philippon Research Institute, Vail, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1682-0444","authenticated-orcid":false,"given":"Justin F. M.","family":"Hollenbeck","sequence":"additional","affiliation":[{"name":"Steadman Philippon Research Institute, Vail, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin A.","family":"Schafer","sequence":"additional","affiliation":[{"name":"Department Orthopedic Surgery, NYU Langone Health, New York, NY, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr","given":"Craig T.","family":"Haytmanek","sequence":"additional","affiliation":[{"name":"Steadman Philippon Research Institute, Vail, CO, USA"},{"name":"The Steadman Clinic, Vail, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2426-170X","authenticated-orcid":false,"given":"Jonathon D.","family":"Backus","sequence":"additional","affiliation":[{"name":"Steadman Philippon Research Institute, Vail, CO, USA"},{"name":"The Steadman Clinic, Vail, CO, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,6,28]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/1938640015620655"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199911000-00005"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2017.09.003"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/107110070202300605"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/2473011420944904"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/1071100713494779"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/1071100719837524"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/107110070602701101"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.fas.2019.09.001"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-016-0055-3"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.3113\/FAI.2012.0984"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3113\/FAI.2011.0704"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.fas.2016.05.317"},{"issue":"4","key":"e_1_3_2_15_2","article-title":"First metatarsophalangeal joint arthrodesis: a narrative review of fixation constructs and their evolution","volume":"13","author":"LaCoste KL","year":"2021","unstructured":"LaCoste KL, Andrews NA, Ray J, Harrelson WM, Shah A. First metatarsophalangeal joint arthrodesis: a narrative review of fixation constructs and their evolution. Cureus. 2021;13(4):e14458.","journal-title":"Cureus"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-016-0809-y"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/107110078000100305"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/1071100714520695"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1177\/107110070202300203"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/24730114241300158"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/10711007221119157"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2019.02.003"},{"issue":"192","key":"e_1_3_2_23_2","first-page":"260","article-title":"The effect of immobilization devices on the load distribution under the foot","volume":"1985","author":"Shereff MJ","unstructured":"Shereff MJ, Bregman AM, Kummer FJ. The effect of immobilization devices on the load distribution under the foot. Clin Orthop Relat Res. 1985(192):260-267.","journal-title":"Clin Orthop Relat Res"}],"container-title":["Foot &amp; Ankle International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10711007251341886","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/10711007251341886","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/10711007251341886","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T21:23:46Z","timestamp":1777411426000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/10711007251341886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,28]]},"references-count":22,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["10.1177\/10711007251341886"],"URL":"https:\/\/doi.org\/10.1177\/10711007251341886","relation":{},"ISSN":["1071-1007","1944-7876"],"issn-type":[{"value":"1071-1007","type":"print"},{"value":"1944-7876","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,28]]}}}