{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T22:52:17Z","timestamp":1777675937137,"version":"3.51.4"},"reference-count":44,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T00:00:00Z","timestamp":1606953600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["The International Journal of High Performance Computing Applications"],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:p>\n                    The electric and magnetic fields around power lines carry an immense amount of information about the power grid and can be used to improve stability, balance loads, conserve power, and reduce outages. To study this, an extremely large model of transmission lines over a 70-km\n                    <jats:sup>2<\/jats:sup>\n                    tract of land near Washington, DC, has been built. The terrain was modeled accurately using 1-m-resolution LIDAR data. The 140-million-element power-line model was solved using the boundary element method, and the solvers were parallelized across DEVCOM Army Research Laboratory\u2019s Centennial supercomputer using a modified version of the domain decomposition method. The code on each node was accelerated using the fast multipole method and, when available, GPUs. Additionally, larger test models were used to characterize the scalability of the code. The largest test model had 10,010,944,000 elements, and was solved on 1,024 nodes in 4.3 hours.\n                  <\/jats:p>","DOI":"10.1177\/1094342020976783","type":"journal-article","created":{"date-parts":[[2020,12,3]],"date-time":"2020-12-03T04:47:19Z","timestamp":1606970839000},"page":"136-153","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Highly parallel boundary element method for solving extremely large, wide-area power-line models"],"prefix":"10.1177","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4958-2526","authenticated-orcid":false,"given":"Ross","family":"Adelman","sequence":"first","affiliation":[{"name":"DEVCOM Army Research Laboratory, Adelphi, MD, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2020,12,3]]},"reference":[{"key":"bibr1-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/TMAG.2017.2725951"},{"key":"bibr2-1094342020976783","volume-title":"Electrostatics Joint Conference","author":"Adelman R","year":"2009"},{"key":"bibr3-1094342020976783","volume-title":"ARL power-line UAV modeling and simulation (ARL-PLUMS) software tool","author":"Adelman RN","year":"2015"},{"key":"bibr4-1094342020976783","unstructured":"Balay S, Abhyankar S, Adams MF, et al. (2019) PETSc Web page. Available at: https:\/\/www.mcs.anl.gov\/petsc. (accessed 23 November 2020)"},{"key":"bibr5-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1098\/rspa.1971.0097"},{"key":"bibr6-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/LAWP.2016.2537779"},{"key":"bibr7-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/0898-1221(96)00004-1"},{"key":"bibr8-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1080\/716100489"},{"key":"bibr9-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/S0045-7825(03)00312-8"},{"key":"bibr10-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/j.enganabound.2005.12.004"},{"key":"bibr11-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/j.elstat.2013.09.002"},{"key":"bibr12-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/MSP.2013.2245726"},{"key":"bibr13-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9991(87)90140-9"},{"key":"bibr14-1094342020976783","volume-title":"Non-contact circuit for real-time electric and magnetic field measurements","author":"Heintzelman SM","year":"2015"},{"key":"bibr15-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/IAS.2015.7356747"},{"key":"bibr16-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/APS.2014.6904704"},{"key":"bibr17-1094342020976783","volume-title":"Communication-avoiding Krylov subspace methods","author":"Hoemmen M","year":"2010"},{"key":"bibr18-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1145\/2063384.2063432"},{"key":"bibr19-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/HPCC.2012.44"},{"key":"bibr20-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/CEFC-06.2006.1632881"},{"key":"bibr21-1094342020976783","volume-title":"IEEE standard for safety levels with respect to human exposure to electromagnetic fields, 0\u20133 kHz","author":"IEEE Standards Coordinating Committee 28","year":"1980"},{"key":"bibr22-1094342020976783","volume-title":"Classical Electrodynamics","author":"Jackson JD","year":"1999"},{"key":"bibr23-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/S0955-7997(96)00050-1"},{"key":"bibr24-1094342020976783","volume-title":"A comparison of measurement techniques to determine electric fields and magnetic flux under EHV overhead power transmission lines","author":"Lambdin DL","year":"1978"},{"key":"bibr25-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1007\/s00607-003-0018-2"},{"key":"bibr26-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1145\/2160718.2160740"},{"key":"bibr27-1094342020976783","doi-asserted-by":"publisher","DOI":"10.2528\/PIER15113001"},{"key":"bibr28-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1145\/2898349"},{"key":"bibr29-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2014.2380438"},{"key":"bibr30-1094342020976783","doi-asserted-by":"publisher","DOI":"10.2528\/PIERM14122301"},{"key":"bibr31-1094342020976783","doi-asserted-by":"publisher","DOI":"10.2528\/PIERM16110309"},{"key":"bibr32-1094342020976783","unstructured":"Narda Safety Test Solutions (2020) Narda Measuring Equipment. Available at: https:\/\/www.narda-sts.com\/en\/products\/. (23 November 2020)."},{"key":"bibr33-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/61.157008"},{"issue":"99","key":"bibr34-1094342020976783","first-page":"1","author":"Peng Z","year":"2017","journal-title":"IEEE Transactions on Components, Packaging and Manufacturing Technology"},{"key":"bibr35-1094342020976783","unstructured":"Quasar Federal Systems (2017) Electric field sensing. Available at: http:\/\/www.quasarfs.com\/solutions-and-services\/electric-field-sensing\/. (accessed 23 November 2020)"},{"key":"bibr36-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.1979.1142171"},{"key":"bibr37-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1137\/0907058"},{"key":"bibr38-1094342020976783","volume-title":"Domain Decomposition: Parallel Multilevel Methods for Elliptic Partial Differential Equations","author":"Smith BF","year":"1996"},{"key":"bibr39-1094342020976783","volume-title":"An examination of electric fields under EHV overhead power transmission lines","author":"Tell RA","year":"1977"},{"key":"bibr40-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/JPROC.2010.2060450"},{"key":"bibr41-1094342020976783","unstructured":"US Energy Information Administration (2020) Revenue from sales of electricity to ultimate customers. Available at: https:\/\/www.eia.gov\/electricity\/annual\/html\/epa_02_03.html. (accessed 23 November 2020)"},{"key":"bibr42-1094342020976783","volume-title":"Electric fields under power lines","author":"Wigdor M","year":"1980"},{"key":"bibr43-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.1984.1143304"},{"key":"bibr44-1094342020976783","doi-asserted-by":"publisher","DOI":"10.1016\/j.cpc.2011.02.013"}],"container-title":["The International Journal of High Performance Computing Applications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1094342020976783","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1094342020976783","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1094342020976783","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T08:17:11Z","timestamp":1777450631000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1094342020976783"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12,3]]},"references-count":44,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["10.1177\/1094342020976783"],"URL":"https:\/\/doi.org\/10.1177\/1094342020976783","relation":{},"ISSN":["1094-3420","1741-2846"],"issn-type":[{"value":"1094-3420","type":"print"},{"value":"1741-2846","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12,3]]}}}