{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T23:27:40Z","timestamp":1777850860650,"version":"3.51.4"},"reference-count":20,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Feline Medicine and Surgery"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>A comparative assessment of systolic blood pressure (SBP) measurement was carried out for anaesthetised and conscious cats by using two non-invasive approaches based on the Doppler method and a newly developed oscillometric instrument.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>SBP was recorded on 131 occasions in 26 cats entering a shelter environment. Six of these cats were monitored while under a general anaesthetic for elective procedures and the rest were conscious during routine health assessment. A paired approach was followed using the Doppler method followed immediately by the oscillometric approach. Mean values and coefficient of variations were calculated. A normal distribution was confirmed before a standard Bland\u2013Altman analysis was completed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The mean SBP (\u00b1SD) for the 131 paired readings was 113.3\u2009\u00b1\u200923.9\u2009mmHg and 116.3\u2009\u00b1\u200926.7\u2009mmHg for the Doppler and oscillometric methods, respectively. The small difference in means was not significant. Anaesthetised cats had significantly lower SBP values than those that were conscious. The data set for 16 cats with three replicated paired measurements and a subset of 12 with five such replicated measurements also provided similar normally distributed mean values and a high correlation coefficient. The Bland\u2013Altman plot suggested a positive bias of the oscillometric approach of +3.07\u2009\u00b1\u200912.3\u2009mmHg (limits of agreement of \u221221.0 to 27.1\u2009mmHg) and +4.93\u2009\u00b1\u20099.38 mmHg (limits of agreement of \u221213.5 to 23.3\u2009mmHg) for the 16- and 12-cat subgroups, respectively. There was 100% agreement between the two methods in allocation to a hypertension class.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and relevance<\/jats:title>\n                    <jats:p>The results establish that the new AutoCAT+ instrument met some of the guidelines for assessing such instruments for veterinary use with cats with a normal range of blood pressure. Further work is needed with a larger data set spanning hypotension to hypertension for complete validation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1098612x261424313","type":"journal-article","created":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T04:02:00Z","timestamp":1770350520000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of Thames Medical CAT+ Doppler and AutoCAT+ Automatic Blood Pressure Monitor devices for non-invasive blood pressure measurement in cats"],"prefix":"10.1177","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-9448-7687","authenticated-orcid":false,"given":"Eleanor","family":"Marriott","sequence":"first","affiliation":[{"name":"Castle Veterinary Clinic, Dorchester, Dorset, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2026,2,5]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/1098612X17693500"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.vaa.2025.03.015"},{"key":"e_1_3_3_4_2","article-title":"Indirect blood pressure determination by Doppler technique in renal hypertensive cats.","volume":"237","author":"Klevans LR","year":"1979","unstructured":"Klevans LR, Hirkaler G, Kovacs JL. Indirect blood pressure determination by Doppler technique in renal hypertensive cats. Am J Physiol 1979; 237: H720\u2013H723.","journal-title":"Am J Physiol"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1998.tb00143.x"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.1992.53.7.1166"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.1995.tb03301.x"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/jvim.15331"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41371-019-0196-9"},{"key":"e_1_3_3_10_2","article-title":"Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats.","volume":"23","author":"Cerna P","year":"2020","unstructured":"Cerna P, Archontakis PE, Cheuk HO, et al. Comparison of Doppler ultrasonic and oscillometric devices (with or without proprietary optimisations) for non-invasive blood pressure measurement in conscious cats. J Feline Med Surg 2020; 23: 121\u201330.","journal-title":"J Feline Med Surg"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/1098612X241231471"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/1098612X231216350"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfms.2004.08.003"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/1098612X231183244"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/1098612X211067015"},{"key":"e_1_3_3_16_2","unstructured":"Snedecor GW Cochran WG. Statistical methods. 8th ed. Iowa State University 1989."},{"key":"e_1_3_3_17_2","unstructured":"Zaiontz C. Lin\u2019s concordance correlation coefficient. Lin\u2019s Concordance Correlation Real Statistics Using Excel. https:\/\/real-statistics.com\/reliability\/interrater-reliability\/lins-concordance-correlation-coefficient\/ (accessed 29 October 2025)."},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.vaa.2019.12.007"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.2007.tb03005.x"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/vcp.13198"},{"key":"e_1_3_3_21_2","article-title":"Reliability associated with the measurement of continuous variables in veterinary medicine: what the different possible indicators tell, and how to use and report them.","volume":"13","author":"Buczinski S.","year":"2023","unstructured":"Buczinski S. Reliability associated with the measurement of continuous variables in veterinary medicine: what the different possible indicators tell, and how to use and report them. Animals (Basel) 2023; 13. DOI: 10.3390\/ani13172793.","journal-title":"Animals (Basel)"}],"container-title":["Journal of Feline Medicine and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1098612X261424313","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1098612X261424313","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1098612X261424313","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:12:49Z","timestamp":1777500769000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1098612X261424313"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,5]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["10.1177\/1098612X261424313"],"URL":"https:\/\/doi.org\/10.1177\/1098612x261424313","relation":{},"ISSN":["1098-612X","1532-2750"],"issn-type":[{"value":"1098-612X","type":"print"},{"value":"1532-2750","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,5]]},"article-number":"1098612X261424313"}}