{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T09:20:38Z","timestamp":1795080038024,"version":"4.10.2"},"reference-count":26,"publisher":"SAGE Publications","issue":"11","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Feline Medicine and Surgery"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The aim of this study was to compare the pull-out strength of cannulated compression headless screws (CCHSs) of two different lengths with that of cortical screws in the feline sacrum.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      In this experimental study, 30 cadavers of adult domestic shorthair cats were randomly assigned to three groups: single 2.4\u2009mm cortical screws engaging 60% of the sacral width (CS 60, n\u2009=\u200910), 2.5\u2009mm CCHSs engaging 60% of the sacral width (CCHSs 60, n\u2009=\u200910), and 2.5\u2009mm CCHSs engaging 40% of the sacral width (CCHS 40, n\u2009=\u200910). Screws were inserted into feline sacra and tested for pull-out strength using a universal testing machine at a constant displacement rate of 0.2\u2009mm\/s up to 20\u2009mm. Peak pull-out force (PPF), displacement at PPF, and stiffness were calculated from the load-displacement curves and compared among groups using Fisher\u2019s ANOVA and the Welch test. Post-hoc pairwise comparisons were performed using Student\u2019s\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -tests and the Games\u2013Howell test. Statistical significance was set at\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2a7d0.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Pairwise comparison of PPF showed significant differences between the CS 60 and CCHS 60 groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.05) and between the CS 60 and CCHS 40 groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.05). No significant difference was detected between the CCHS 60 and CCHS 40 groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.98). For displacement at PPF and stiffness, no significant differences were identified in the pairwise comparison.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions and relevance:<\/jats:title>\n                    <jats:p>Fully threaded cortical screws provide greater holding strength than partially threaded CCHSs in cadaveric feline sacra. In addition, a single short CCHS offers holding strength comparable to that of a CCHS of the conventionally recommended length.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1098612x261494395","type":"journal-article","created":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T05:59:44Z","timestamp":1790229584000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Pull-out strength of cannulated compression headless screws and cortical screws in the feline sacrum"],"prefix":"10.1177","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4758-0458","authenticated-orcid":false,"given":"Matthias","family":"Kornmayer","sequence":"first","affiliation":[{"name":"LMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jana","family":"Klement","sequence":"additional","affiliation":[{"name":"Veterinary practice Dr. Zauscher, Odelzhausen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6928-4089","authenticated-orcid":false,"given":"Yury","family":"Zablotski","sequence":"additional","affiliation":[{"name":"LMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Thorw\u00e4chter","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich, University Hospital, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-9050-1296","authenticated-orcid":false,"given":"Josef","family":"Wieser","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich, University Hospital, Ludwig-Maximilians-Universit\u00e4t M\u00fcnchen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"crossref","unstructured":"Bookbinder PF Flanders JA. Characteristics of pelvic fracture in the cat. Vet Comp Orthop Traumatol 1992; 5: 122\u2013127. https:\/\/doi.org\/10.1055\/s-0038-1633081","DOI":"10.1055\/s-0038-1633081"},{"key":"e_1_3_2_3_2","doi-asserted-by":"crossref","unstructured":"Meeson RL Geddes AT. Management and long-term outcome of pelvic fractures: A retrospective study of 43 cats. J Feline Med Surg 2017; 19: 36\u201341. https:\/\/doi.org\/10.1177\/1098612X15606958","DOI":"10.1177\/1098612X15606958"},{"key":"e_1_3_2_4_2","doi-asserted-by":"crossref","unstructured":"Bird FG de Vicente F. Conservative management of sacroiliac luxation fracture in cats: Medium- to long-term functional outcome. J Feline Med Surg 2020; 22: 575\u2013581. https:\/\/doi.org\/10.1177\/1098612X19867516","DOI":"10.1177\/1098612X19867516"},{"key":"e_1_3_2_5_2","doi-asserted-by":"crossref","unstructured":"Shales C Moores A Kulendra E et al. Stabilization of sacroiliac luxation in 40 cats using screws inserted in lag fashion. Vet Surg 2010; 39: 696\u2013700. https:\/\/doi.org\/10.1111\/j.1532-95X.2010.00699.x","DOI":"10.1111\/j.1532-950X.2010.00699.x"},{"key":"e_1_3_2_6_2","doi-asserted-by":"crossref","unstructured":"Kaderly RE. Stabilization of bilateral sacroiliac fracture-luxations in small animals with a single transsacral screw. Vet Surg 1991; 10: 91\u201396. https:\/\/doi.org\/10.1111\/j.1532-950x.1991.tb00313.x","DOI":"10.1111\/j.1532-950X.1991.tb00313.x"},{"key":"e_1_3_2_7_2","doi-asserted-by":"crossref","unstructured":"Silveira F Quinn RJ Adrian AM et al. Evaluation of the use of intra-operative radiology for open placement of lag screws for the stabilization of sacroiliac luxation in cats. Vet Comp Orthop Traumatol 2017; 30: 69\u201374. https:\/\/doi.org\/10.3415\/VCOT-15-12-0201","DOI":"10.3415\/VCOT-15-12-0201"},{"key":"e_1_3_2_8_2","doi-asserted-by":"crossref","unstructured":"Rollins A Balfour R Szabo D et al. Evaluation of fluoroscopic-guided closed reduction versus open reduction of sacroiliac fracture-luxations stabilized with a lag screw. Vet Comp Orthop Traumatol 2019; 32: 467\u2013474. https:\/\/doi.org\/10.1055\/s-0039-1693471","DOI":"10.1055\/s-0039-1693471"},{"key":"e_1_3_2_9_2","doi-asserted-by":"crossref","unstructured":"Wills DJ Neville-Towle J Podadera J et al. Computed tomographic evaluation of the accuracy of minimally invasive sacroiliac screw fixation in cats. Vet Comp Orthop Traumatol 2022; 35: 119\u2013127. https:\/\/doi.org\/10.1055\/s-0041-1736648","DOI":"10.1055\/s-0041-1736648"},{"key":"e_1_3_2_10_2","first-page":"938","volume-title":"Veterinary surgery: Small animal","author":"Moens NMM","year":"2018","unstructured":"Moens NMM, DeCamp CE. Fractures of the pelvis. In: Johnston SA, Tobias KM (eds) Veterinary surgery: Small animal. Vol 1. 2nd ed. Elsevier Saunders, 2018, pp.938\u2013956.","edition":"2"},{"key":"e_1_3_2_11_2","doi-asserted-by":"crossref","unstructured":"Jourdain M Fernandes D V\u00e9drine B et al. Fluoroscopically-assisted closed reduction and percutaneous fixation of sacroiliac luxations in cats using 2.4\u2009mm headless cannulated compression screws: Description evaluation and clinical outcome. Vet Surg 2024; 53: 603\u2013612. https:\/\/doi.org\/10.1111\/vsu.14070","DOI":"10.1111\/vsu.14070"},{"key":"e_1_3_2_12_2","doi-asserted-by":"crossref","unstructured":"De Jong L Proot JLJ Pillin LJP et al. Minimally invasive placement of cannulated headless compression screws for reduction of sacroiliac luxation in 14 cats. Vet Comp Orthop Traumatol 2025; 38: 194\u2013199. https:\/\/doi.org\/10.1055\/s-0044-1793944","DOI":"10.1055\/s-0044-1793944"},{"key":"e_1_3_2_13_2","doi-asserted-by":"crossref","unstructured":"Hanlon J Hudson CC Litsky AS et al. Mechanical evaluation of canine sacroiliac joint stabilization using two short screws. Vet Surg 2022; 51: 1061\u20131069. https:\/\/doi.org\/10.1111\/vsu.13857","DOI":"10.1111\/vsu.13857"},{"key":"e_1_3_2_14_2","doi-asserted-by":"crossref","unstructured":"Schreiber KRL Thibault A Hamon M et al. Stabilization of 82 sacroiliac luxations in 67 cats using two sacroiliac screws (2014\u20132023). Vet Surg 2024; 53: 1366\u20131376. https:\/\/doi.org\/10.1111\/vsu.14167","DOI":"10.1111\/vsu.14167"},{"key":"e_1_3_2_15_2","doi-asserted-by":"crossref","unstructured":"Burger M Forterre F Brunnberg L. Surgical anatomy of the feline sacroiliac joint for lag screw fixation of sacroiliac fracture-luxation. Vet Comp Orthop Traumatol 2004; 17: 146\u2013151. https:\/\/doi.org\/10.1055\/s-0038-1632803","DOI":"10.1055\/s-0038-1632803"},{"key":"e_1_3_2_16_2","doi-asserted-by":"crossref","unstructured":"Radasch RM Merkley DF Hoefle WD et al. Static strength evaluation of sacroiliac fracture-separation repairs. Vet Surg 1990; 19: 155\u2013161. https:\/\/doi.org\/10.1111\/j.1532-950x.1990.tb01158.x","DOI":"10.1111\/j.1532-950X.1990.tb01158.x"},{"key":"e_1_3_2_17_2","doi-asserted-by":"crossref","unstructured":"Kang A Lee H Lee A et al. Biomechanical comparison of double 2.3-mm headless cannulated self-compression screws and single 3.5-mm cortical screw in lag fashion in a canine sacroiliac luxation model: A small dog cadaveric study. Vet Comp Orthop Traumatol 2024; 37: 13\u201322. https:\/\/doi.org\/10.1055\/s-0043-1771508","DOI":"10.1055\/s-0043-1771508"},{"key":"e_1_3_2_18_2","doi-asserted-by":"crossref","unstructured":"Klement J Wieser J Thorw\u00e4chter C et al. Rotational stability in a feline sacroiliac luxation model: Biomechanical comparison of cannulated compression headless screws and cortical screws applied in positional or lag fashion. Animals (Basel) 2026; 16. https:\/\/doi.org\/10.3390\/ani16101564","DOI":"10.3390\/ani16101564"},{"key":"e_1_3_2_19_2","doi-asserted-by":"crossref","unstructured":"Ramaswamy R Evans E Kosashvilli Y. Holding power of variable pitch screws in osteoporotic osteopenic and normal bone: Are all screws created equal? Injury 2010; 41: 179\u2013183. https:\/\/doi.org\/10.1016\/j.injury.2009.08.015","DOI":"10.1016\/j.injury.2009.08.015"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4612-2326-9_2"},{"key":"e_1_3_2_21_2","doi-asserted-by":"crossref","unstructured":"Chapman JR Harrington RM Lee KM et al. Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 1996; 118: 391\u2013398. https:\/\/doi.org\/10.1115\/1.2796022","DOI":"10.1115\/1.2796022"},{"key":"e_1_3_2_22_2","unstructured":"Depuy Synthes. Cannulated compression headless screws (CCHS). 2.0 2.5 3.0 3.5 4.0 4.5 5.5 6.5 7.5mm. Surgical technique. https:\/\/a490ebc3686a416702a4-875c9cad01df4876deaf64b6bbcf2205.ssl.cf2.rackcdn.com\/ota_3faeb208bd6827b31b625d3a475a1d20.pdf (2019 accessed 12 May 2024)."},{"key":"e_1_3_2_23_2","doi-asserted-by":"crossref","unstructured":"Nagaraja S Palepu V. Comparisons of anterior plate screw pullout strength between polyurethrane foams and thoracolumbar cadaveric vertebrae. J Biomech Eng 2016; 138. https:\/\/doi.org\/10.1115\/1.4034427","DOI":"10.1115\/1.4034427"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199708000-00035"},{"key":"e_1_3_2_25_2","doi-asserted-by":"crossref","unstructured":"Kissel CG Friedersdorf SC Foltz DS et al. Comparison of pullout strength of small-diameter cannulated and solid-core screws. J Foot Ankle Surg 2003; 42: 334\u2013338. https:\/\/doi.org\/10.1053\/j.jfas.2003.09.007","DOI":"10.1053\/j.jfas.2003.09.007"},{"key":"e_1_3_2_26_2","doi-asserted-by":"crossref","unstructured":"Pollard JD Deyhim A Rigby RB et al. Comparison of pullout strength between 3.5-mm fully threaded bicortical screws and 4.0-mm partially threaded cancellous screws in the fixation of medial malleolar fractures. J Foot Ankle Surg 2010; 49: 248\u2013252. https:\/\/doi.org\/10.1053\/j.jfas.2010.02.006","DOI":"10.1053\/j.jfas.2010.02.006"},{"key":"e_1_3_2_27_2","doi-asserted-by":"crossref","unstructured":"M\u00fcller J-U Nowak S Matthes M et al. Biomechanical comparison of two different compression screws for the treatment of odontoid fractures in human dens axis specimen. Clin Biomech (Bristol) 2024; 111. https:\/\/doi.org\/10.1016\/j.clinbiomech.2023.106162","DOI":"10.1016\/j.clinbiomech.2023.106162"}],"container-title":["Journal of Feline Medicine and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1098612X261494395","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1098612X261494395","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1098612X261494395","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T09:05:41Z","timestamp":1795079141000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1098612X261494395"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1177\/1098612X261494395"],"URL":"https:\/\/doi.org\/10.1177\/1098612x261494395","relation":{},"ISSN":["1098-612X","1532-2750"],"issn-type":[{"value":"1098-612X","type":"print"},{"value":"1532-2750","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]},"article-number":"1098612X261494395"}}