{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:10:13Z","timestamp":1777579813639,"version":"3.51.4"},"reference-count":27,"publisher":"SAGE Publications","issue":"2_suppl","license":[{"start":{"date-parts":[[2001,7,1]],"date-time":"2001-07-01T00:00:00Z","timestamp":993945600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2001,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>We compared detection rates of glaucomatous visual field defects (VFDs) between a conventional rectangular stimulus grid and locally condensed test point arrangements in morphologically suspicious regions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Humphrey Field Analyzer model 630 (HFA I, program 30-2 with a rectangular 6\u00b0 \u00d7 6\u00b0 grid) was used as the conventional perimetric method. Individual local test-point condensation was realized by fundus-oriented perimetry (FOP) on the Tuebingen Computer Campimeter (TCC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Of a total of 66 glaucoma patients, or suspected sufferers, 23 showed normal findings and 27 showed pathological findings with both methods. In 15 cases we found normal visual fields in HFA 30-2, whereas FOP revealed early glaucomatous functional damage. Only one case showed pathological HFA results, while FOP was normal. Detection rates of VFDs significantly differed between the two methods (p &lt; 0.001; sign test).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>FOP, using individually condensed test grids, significantly increases detection rates of glaucomatous VFDs in morphologically suspicuous areas compared with a conventional HFA 30-2 technique using equidistant rectangular (6\u00b0 \u00d7 6\u00b0) test point arrangements.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/112067210101102s07","type":"journal-article","created":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T00:30:25Z","timestamp":1516321825000},"page":"57-62","source":"Crossref","is-referenced-by-count":14,"title":["Evaluation of Glaucomatous Visual Field Loss with Locally Condensed Grids Using Fundus-Oriented Perimetry (FOP)"],"prefix":"10.1177","volume":"11","author":[{"given":"U.","family":"Schiefer","sequence":"first","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. II;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Malsam","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. II;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Flad","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. II;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Stumpp","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. II;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T. J.","family":"Dietrich","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. II;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Paetzold","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. II;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Vonthein","sequence":"additional","affiliation":[{"name":"Department of Medical Biometry, University of T\u00fcbingen;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Knorr","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. I, T\u00fcbingen - Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.O.","family":"Denk","sequence":"additional","affiliation":[{"name":"University Eye Hospital T\u00fcbingen, Dept. I, T\u00fcbingen - Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2001,7,1]]},"reference":[{"key":"bibr1-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1035280"},{"key":"bibr2-112067210101102S07","first-page":"1","author":"Schiefer U.","year":"1996","journal-title":"Patent: Perimetrisches Untersuchungsverfahren - Fundusgest\u00fctzte Perimetrie II."},{"key":"bibr3-112067210101102S07","first-page":"107","volume-title":"Perimetry update 1996\/1997.","author":"Schiefer U.","year":"1997"},{"key":"bibr4-112067210101102S07","first-page":"261","volume-title":"Perimetry update 1998\/1999.","author":"Schiefer U.","year":"1999"},{"key":"bibr5-112067210101102S07","first-page":"207","volume-title":"Perimetry update 1996\/1997.","author":"Benda N.","year":"1997"},{"key":"bibr6-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00295-8"},{"key":"bibr7-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00294-6"},{"key":"bibr8-112067210101102S07","first-page":"217","volume":"4","author":"Wabbels B.","year":"1995","journal-title":"German J Ophthalmol"},{"key":"bibr9-112067210101102S07","first-page":"471","volume-title":"Perimetry update 1996\/1997.","author":"Dietrich T.J.","year":"1997"},{"key":"bibr10-112067210101102S07","first-page":"S125","volume":"5","author":"Dietrich T.J.","year":"1996","journal-title":"German J Ophthalmol"},{"key":"bibr11-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1991.01080120068028"},{"key":"bibr12-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.81.6.452"},{"key":"bibr13-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00026-3"},{"key":"bibr14-112067210101102S07","first-page":"8","author":"Morales J.","year":"1997","journal-title":"Ocul Surg News"},{"key":"bibr15-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.1998.760408.x"},{"key":"bibr16-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.1997.tb00392.x"},{"key":"bibr17-112067210101102S07","first-page":"17","volume-title":"Perimetry update 1998\/1999.","author":"Langerhorst C.T.","year":"1999"},{"key":"bibr18-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.118.4.489"},{"key":"bibr19-112067210101102S07","first-page":"S84","volume":"41","author":"Keltner J.L.","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bibr20-112067210101102S07","first-page":"S876","volume":"39","author":"Schwartz M.","year":"1998","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bibr21-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1006\/exnr.1998.6811"},{"key":"bibr22-112067210101102S07","first-page":"349","volume":"41","author":"Schwartz M.","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bibr23-112067210101102S07","first-page":"67","volume-title":"Perimetry update 1996\/1997.","author":"Langerhorst C.T.","year":"1997"},{"key":"bibr24-112067210101102S07","first-page":"S581","volume":"40","author":"Westcott M.C.","year":"1999","journal-title":"High spatial resolution perimetry can identify scotomas not apparent on conventional Humphrey testing. Invest Ophthalmol Vis Sci"},{"key":"bibr25-112067210101102S07","first-page":"197","volume":"4","author":"Rohrschneider K.","year":"1995","journal-title":"German J Ophthalmol"},{"key":"bibr26-112067210101102S07","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-009-9611-3_37"},{"key":"bibr27-112067210101102S07","first-page":"351","volume":"1","author":"Ohta Y.","year":"1978","journal-title":"Docum Ophthal Proc Series"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210101102S07","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210101102S07","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:38:37Z","timestamp":1777405117000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/112067210101102S07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,7]]},"references-count":27,"journal-issue":{"issue":"2_suppl","published-print":{"date-parts":[[2001,7]]}},"alternative-id":["10.1177\/112067210101102S07"],"URL":"https:\/\/doi.org\/10.1177\/112067210101102s07","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,7]]}}}