{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:13:57Z","timestamp":1777580037860,"version":"3.51.4"},"reference-count":4,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2003,7,1]],"date-time":"2003-07-01T00:00:00Z","timestamp":1057017600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2003,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To report on the correction of marked regular corneal astigmatism due to keratoconus by toric intraocular lenses (IOL).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting<\/jats:title>\n                    <jats:p>University eye hospital.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A 66-year-old woman presented with cataract and unilateral keratoconus (keratometric readings: 50.2\/41.3 diopters [D]). She underwent routine cataract surgery with implantation of a foldable posterior chamber toric IOL (refractive power: +10.0 D sphere\/+12.0 D cylinder). A 68-year-old surgically aphakic woman presented with peripheral accentuated keratoconus with regular and stable corneal astigmatism (keratometric readings: 39.75\/61.5 D). She underwent secondary implantation of a foldable toric IOL (refractive power: \u20139.0 D sphere\/+30.0 D cylinder) into the ciliary sulcus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>After a follow-up period of 4 months, visual acuity increased to 0.70 with a correction of +0.75 sphere \u20132.5 cylinder\/84\u00b0 in Patient 1; after a follow-up period of 6 months, visual acuity increased to 0.60 with a correction of +1.0 \u20132.0\/90\u00b0 in Patient 2.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Foldable toric silicone IOL may be a surgical option in the management of regular marked corneal astigmatism caused by keratoconus.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/112067210301300612","type":"journal-article","created":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T00:35:36Z","timestamp":1516322136000},"page":"577-579","source":"Crossref","is-referenced-by-count":42,"title":["Treatment of Keratoconus by Toric Foldable Intraocular Lenses"],"prefix":"10.1177","volume":"13","author":[{"given":"G.","family":"Sauder","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Faculty of Clinical Medicine Mannheim, Ruprecht-Karls-University of Heidelberg, Mannheim - Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.B.","family":"Jonas","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Clinical Medicine Mannheim, Ruprecht-Karls-University of Heidelberg, Mannheim - Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2003,7,1]]},"reference":[{"key":"bibr1-112067210301300612","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00317-5"},{"key":"bibr2-112067210301300612","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00272-2"},{"key":"bibr3-112067210301300612","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1007\/s003470170077","volume":"98","author":"Michels A.","year":"2001","journal-title":"Ophthalmologe"},{"key":"bibr4-112067210301300612","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00266-9"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210301300612","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210301300612","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:39:24Z","timestamp":1777405164000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/112067210301300612"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,7]]},"references-count":4,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2003,7]]}},"alternative-id":["10.1177\/112067210301300612"],"URL":"https:\/\/doi.org\/10.1177\/112067210301300612","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,7]]}}}