{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T19:56:48Z","timestamp":1777579008146,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2006,1,1]],"date-time":"2006-01-01T00:00:00Z","timestamp":1136073600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2006,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the ability of two types of accommodative intraocular lenses (IOLs) to provide uncorrected near and distance visual acuity (VA) after cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 108 eyes of 75 patients underwent cataract surgery by phacoemulsification and IOL implantation either bilaterally or monocularly with one of two types of accommodative IOLs: the AT-45 lens (69 eyes) or the 1-CU lens (39 eyes). Patients were followed for up to 1 year after cataract surgery. Near VA was measured through the distance correction to obtain the true near vision effect of the accommodating IOL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Uncorrected distance VA of 20\/30 or better was achieved by 84.6% of the bilaterally implanted 1-CU patients and 73.6% of the bilaterally implanted AT-45 IOL patients 1 year following surgery. Uncorrected near VA of J1 or better was achieved by 42% of the patients with the bilateral 1-CU implant and 36.8% of the patients with the bilateral AT-45 implant. For J3 or better near acuity, the values were 92.3% for the bilateral 1-CU patients and 84.2% for the bilateral AT-45 patients at 1 year. A total of 54% of the eyes with 1-CU implants underwent a mild myopic shift (&lt;1.0 D), 21% had a mild hyperopic shift, and 45% of the eyes were emmetropic at 1 year.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Both accommodative IOLs provided good near and distance vision postoperatively. The 1-CU IOL appears clinically to provide slightly better uncorrected distance and distance-corrected near VA than the AT-45 lens.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/112067210601600107","type":"journal-article","created":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T00:48:21Z","timestamp":1516322901000},"page":"33-39","source":"Crossref","is-referenced-by-count":10,"title":["Accommodative Intraocular Lenses: Short-Term Visual Results of Two Different Lens Types"],"prefix":"10.1177","volume":"16","author":[{"given":"L.","family":"Buratto","sequence":"first","affiliation":[{"name":"Centro Ambrosiano di Microchirurgia Oculare, Milano - Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Di Meglio","sequence":"additional","affiliation":[{"name":"Centro Ambrosiano di Microchirurgia Oculare, Milano - Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2006,1,1]]},"reference":[{"key":"bibr1-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00283-1"},{"key":"bibr2-112067210601600107","first-page":"17","volume-title":"Presbyopia: A Surgical Textbook.","author":"Pandey S.K.","year":"2002"},{"key":"bibr3-112067210601600107","first-page":"151","volume-title":"Basic and Clinical Science Course.","author":"American Academy of Ophthalmology.","year":"2003"},{"key":"bibr4-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00704-6"},{"key":"bibr5-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.05.007"},{"key":"bibr6-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00664-3"},{"key":"bibr7-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00722-X"},{"key":"bibr8-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(96)80040-X"},{"key":"bibr9-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.76.6.336"},{"key":"bibr10-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00862-5"},{"key":"bibr11-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(96)80105-2"},{"key":"bibr12-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00779-5"},{"key":"bibr13-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.121.12.1722"},{"key":"bibr14-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00413-9"},{"key":"bibr15-112067210601600107","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1007\/s00347-002-0721-y","volume":"99","author":"Kuchle M.","year":"2002","journal-title":"Ophthalmologe"},{"key":"bibr16-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00072-5"},{"key":"bibr17-112067210601600107","first-page":"1162","volume":"40","author":"Strenk S.A.","year":"1999","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"bibr18-112067210601600107","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01652-8"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210601600107","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210601600107","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:36:26Z","timestamp":1777404986000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/112067210601600107"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["10.1177\/112067210601600107"],"URL":"https:\/\/doi.org\/10.1177\/112067210601600107","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,1]]}}}