{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:09:38Z","timestamp":1777579778673,"version":"3.51.4"},"reference-count":15,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T00:00:00Z","timestamp":1230768000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2009,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The authors present a patient with Marfan syndrome who underwent cataract surgery using a novel device for fixation of capsular bag.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The capsule fixation device (CFD) is poly(methyl methacrylate) arch with double-armed bent hook that can be introduced into the anterior chamber through the clear corneal incision, placed with a rest on the capsule equator, and sutured to the sclera without injury of the capsular bag. A 16-year-old patient with Marfan syndrome underwent consecutive phacoemulsification with in-the-bag intraocular lens and CFD implantation on both eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>During the surgery handling the CFD was technically simple with good visualization. The preoperative best-corrected visual acuity was 0.3 and 0.1 and postoperatively 0.6 and 0.8 in the right and left eyes, respectively. The postoperative follow-up was over 9 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Use of the CFD was successful in a case of lens subluxation with no complications observed during the period of follow-up.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/112067210901900123","type":"journal-article","created":{"date-parts":[[2018,1,19]],"date-time":"2018-01-19T00:54:25Z","timestamp":1516323265000},"page":"143-146","source":"Crossref","is-referenced-by-count":1,"title":["Capsule Fixation Device for Cataract Surgery"],"prefix":"10.1177","volume":"19","author":[{"given":"N.M.","family":"Sergienko","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, National Medical Academy of Postgraduate Education, Kiev - Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.N.","family":"Kondratenko","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, National Medical Academy of Postgraduate Education, Kiev - Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.K.","family":"Yakimov","sequence":"additional","affiliation":[{"name":"Eye Microsurgery Center, Kiev - Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,1,18]]},"reference":[{"key":"bibr1-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80126-5"},{"key":"bibr2-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80218-6"},{"key":"bibr3-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00238-4"},{"key":"bibr4-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.02.048"},{"key":"bibr5-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.12.022"},{"key":"bibr6-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.12.060"},{"key":"bibr7-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00924-5"},{"key":"bibr8-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01604-8"},{"key":"bibr9-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.11.044"},{"key":"bibr10-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.06.050"},{"key":"bibr11-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.12.070"},{"key":"bibr12-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.041"},{"key":"bibr13-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.077"},{"key":"bibr14-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.05.016"},{"key":"bibr15-112067210901900123","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.08.040"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210901900123","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/112067210901900123","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:38:30Z","timestamp":1777405110000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/112067210901900123"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,1]]}},"alternative-id":["10.1177\/112067210901900123"],"URL":"https:\/\/doi.org\/10.1177\/112067210901900123","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,1]]}}}