{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T11:34:22Z","timestamp":1782300862497,"version":"3.54.5"},"reference-count":25,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2018,4,5]],"date-time":"2018-04-05T00:00:00Z","timestamp":1522886400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2018,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2\u2009\u00b1\u20097.4\u2009years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6\u2009months after surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p\u2009\u2264\u20090.02). Distance corrected near visual acuity was 0.13\u2009\u00b1\u20090.10, 0.13\u2009\u00b1\u20090.13, and 0.13\u2009\u00b1\u20090.08 at 1, 3, and 6\u2009months after surgery, respectively (p\u2009=\u20090.82). Distance corrected intermediate visual acuities were 0.09\u2009\u00b1\u20090.13, 0.13\u2009\u00b1\u20090.15, and 0.12\u2009\u00b1\u20090.12 at 1, 3, and 6\u2009months, postoperatively. Binocular contrast sensitivity was 1.86\u2009\u00b1\u20090.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30\u2009LogMAR between defocus levels of +0.50 to \u22123.00\u2009D. The near activity visual questionnaire scores improved significantly with the surgery (p\u2009&lt;\u20090.01).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/1120672118762231","type":"journal-article","created":{"date-parts":[[2018,4,5]],"date-time":"2018-04-05T05:46:36Z","timestamp":1522907196000},"page":"419-424","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":71,"title":["Clinical outcomes with a diffractive trifocal intraocular lens"],"prefix":"10.1177","volume":"28","author":[{"given":"Jorge L","family":"Ali\u00f3","sequence":"first","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"},{"name":"Division of Ophthalmology, Universidad Miguel Hern\u00e1ndez, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana B","family":"Plaza-Puche","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge L","family":"Ali\u00f3 del Barrio","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"},{"name":"Division of Ophthalmology, Universidad Miguel Hern\u00e1ndez, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Amat-Peral","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vicente","family":"Ortu\u00f1o","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pilar","family":"Y\u00e9bana","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olena","family":"Al-Shymali","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfredo","family":"Vega-Estrada","sequence":"additional","affiliation":[{"name":"Vissum Ophthalmological Corporation, Alicante, Spain"},{"name":"Division of Ophthalmology, Universidad Miguel Hern\u00e1ndez, Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2018,4,5]]},"reference":[{"key":"bibr1-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2017.03.005"},{"key":"bibr2-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.09.030"},{"key":"bibr3-1120672118762231","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000638"},{"key":"bibr4-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-017-0076-8"},{"key":"bibr5-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-017-0462-y"},{"key":"bibr6-1120672118762231","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S136164"},{"key":"bibr7-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1364\/OPEX.14.000518"},{"key":"bibr8-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.07.033"},{"key":"bibr9-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.03.037"},{"key":"bibr10-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.04.013"},{"key":"bibr11-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.06.025"},{"key":"bibr12-1120672118762231","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000935"},{"key":"bibr13-1120672118762231","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20131021-05"},{"key":"bibr14-1120672118762231","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140903-06"},{"key":"bibr15-1120672118762231","doi-asserted-by":"publisher","DOI":"10.5301\/ejo.5000780"},{"key":"bibr16-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-9234"},{"key":"bibr17-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.05.001"},{"key":"bibr18-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.04.017"},{"key":"bibr19-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.06.034"},{"key":"bibr20-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00562-9"},{"key":"bibr21-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.05.046"},{"key":"bibr22-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.09.017"},{"key":"bibr23-1120672118762231","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-12"},{"key":"bibr24-1120672118762231","doi-asserted-by":"publisher","DOI":"10.1111\/ceo.13084"},{"key":"bibr25-1120672118762231","doi-asserted-by":"crossref","first-page":"414","DOI":"10.3928\/1081-597X-20010701-02","volume":"17","author":"Doshi JB","year":"2001","journal-title":"J Refract Surg"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1120672118762231","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1120672118762231","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1120672118762231","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:43:51Z","timestamp":1777405431000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1120672118762231"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,5]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["10.1177\/1120672118762231"],"URL":"https:\/\/doi.org\/10.1177\/1120672118762231","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,5]]}}}