{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T02:36:04Z","timestamp":1794018964683,"version":"4.8.0"},"reference-count":30,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2022,9,26]],"date-time":"2022-09-26T00:00:00Z","timestamp":1664150400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2023,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To analyze the effect of decentration and tilt on four novel non diffractive extended range of vision intraocular lenses (IOLs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Acrysof Vivity, LuxSmart Crystal, RayOne EMV and Tecnis Eyhance were compared on the optical bench (power of 22 D each). Modulation transfer functions were obtained and Strehl ratio was calculated in an ISO-2 model. Apertures of 3\u2005mm and 4.5\u2005mm were applied. For qualitative assessment, United States Airforce (USAF) chart images were evaluated. Additional to centered IOLs, tilt of 5 degrees and decentration of 1\u2005mm were applied.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>RayOne EMV was very robust against misalignment but had considerable deterioration of modulation transfer function (MTF) for large aperture with USAF images seriously blurred. Tilt and decentration decreased the performance of Eyhance significantly but had minor impact on the performance of Vivity and LuxSmart. For 4.5\u2005mm aperture, MTF and Strehl ratio decreased markedly for all IOLs compared to 3\u2005mm aperture size. The best MTF and Strehl ratio was obtained for Eyhance IOL well centered for both sizes of aperture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Tilt and decentration had a major impact on the performance of Eyhance only, which performed best of all IOLs tested when well centered. With large aperture, performance of all IOLs significantly decreased. Manufacturer's different approaches for these novel IOLs to increase depth of focus by increasing spherical aberration lead to a different performance in respect to contrast function and sensitivity to misalignment. Our results apply to the distance vision. Near vision performance will be evaluated in a separate investigation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721221128864","type":"journal-article","created":{"date-parts":[[2022,9,27]],"date-time":"2022-09-27T00:46:56Z","timestamp":1664239616000},"page":"933-942","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":23,"title":["Effect of decentration and tilt on four novel extended range of vision intraocular lenses regarding far distance"],"prefix":"10.1177","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7537-8820","authenticated-orcid":false,"given":"Ruediger","family":"Schmid","sequence":"first","affiliation":[{"name":"accuratis, Practice for Refractive Eye Surgery, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Holger","family":"Luedtke","sequence":"additional","affiliation":[{"name":"accuratis, Practice for Refractive Eye Surgery, Ulm, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6341-9069","authenticated-orcid":false,"given":"Andreas F.","family":"Borkenstein","sequence":"additional","affiliation":[{"name":"Borkenstein & Borkenstein, Private practice at Privatklinik der Kreuzschwestern, Graz, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,9,26]]},"reference":[{"key":"bibr1-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.09.039"},{"key":"bibr2-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000293"},{"key":"bibr3-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.07.014"},{"key":"bibr4-11206721221128864","first-page":"CD003169","volume":"2016","author":"De Silva SR","year":"2016","journal-title":"Cochrane Database Syst Rev"},{"key":"bibr5-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.04.010"},{"key":"bibr6-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.06.033"},{"key":"bibr7-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.07.034"},{"key":"bibr8-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05362-2"},{"key":"bibr9-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000399"},{"key":"bibr10-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000061"},{"key":"bibr11-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.05.059"},{"key":"bibr12-11206721221128864","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170217-01"},{"key":"bibr13-11206721221128864","unstructured":"Rayner. https:\/\/rayner.com\/wp-content\/uploads\/2020\/10\/RayOne-EMV-First-Clinical-Results.pdf (2020, accessed 02 October 2021)."},{"key":"bibr14-11206721221128864","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200612-01"},{"key":"bibr15-11206721221128864","unstructured":"Food and Drug Administration. Summary of safety and effectiveness data. AcrySofTM IQ VivityTM Extended Vision Intraocular Lens. PMA P930014\/S126. https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930014S126B.pdf (2020, accessed 02 October 2021)."},{"key":"bibr16-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2011.10.003"},{"key":"bibr17-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2011.05.006"},{"key":"bibr18-11206721221128864","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20171004-02"},{"key":"bibr19-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-020-05053-4"},{"key":"bibr20-11206721221128864","first-page":"20","volume":"3","author":"Bajrovic S","year":"2018","journal-title":"GlobalCONTACT"},{"key":"bibr21-11206721221128864","unstructured":"TRIOPTICS GmbH. https:\/\/trioptics.com\/products\/optispheric-focal-length-and-radius-measurement\/ (accessed 02 October 2021)."},{"key":"bibr22-11206721221128864","unstructured":"R Core Team. R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. https:\/\/www.R-project.org\/ (2019, accessed 02 October 2021)."},{"key":"bibr23-11206721221128864","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200710-01"},{"key":"bibr24-11206721221128864","doi-asserted-by":"publisher","DOI":"10.3390\/vision4030041"},{"key":"bibr25-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0444"},{"key":"bibr26-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.10.068"},{"key":"bibr27-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.049"},{"key":"bibr28-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0156227"},{"key":"bibr29-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-016-0184-6"},{"key":"bibr30-11206721221128864","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001495"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721221128864","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721221128864","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721221128864","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:44:22Z","timestamp":1777405462000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721221128864"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,26]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["10.1177\/11206721221128864"],"URL":"https:\/\/doi.org\/10.1177\/11206721221128864","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,26]]}}}