{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T17:51:32Z","timestamp":1792518692408,"version":"4.5.0"},"reference-count":24,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T00:00:00Z","timestamp":1694995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the viability and precision of measuring the distance from the limbus to extraocular muscle insertion using anterior segment optical coherence tomography (AS-OCT) and panoramic ultrasound biomicroscopy (UBM) before and after strabismus surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We recruited primary strabismus patients and measured the limbus-insertion distance by AS-OCT and UBM preoperatively, 2 weeks, and 1, 3, and 6 months postoperatively. Values were also measured using callipers intraoperatively before and after the planned procedures. Preoperative AS-OCT and UBM values were compared to intraoperative calliper measurements as the gold standard. Postoperative AS-OCT and UBM values were compared to the new postoperative limbus-insertion distance. The limit of agreement deemed clinically acceptable was defined as 1 mm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 85 horizontal muscles of 40 patients, including 48 lateral rectus muscles and 37 medial rectus muscles, were analysed. Primary muscles could be successfully detected by AS-OCT (95%) and UBM (100%). At 2 weeks and 1, 3, and 6 months postoperatively, the new rectus muscle attachment site detection rate by AS-OCT was 6%, 32%, 80%, and 89%, respectively, and that by UBM was 24%, 60%, 85%, and 93%, respectively. The Bland\u2013Altman plots revealed better consistency in pairs of AS-OCT, UBM, and calliper measurements of primary muscles than postoperative muscles. For primary muscles, 89% of AS-OCT measurements fell within the permissible range of surgical measurements (1 mm), but this dropped to 67% at 6 months postoperatively (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; 0.001). The accuracy of UBM measurements of primary muscles was 81%, and this decreased to 59% at 6 months postoperatively (\n                      <jats:italic>P<\/jats:italic>\n                      = 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>AS-OCT and UBM performed well in terms of imaging primary horizontal rectus muscles, but showed decreased accuracy and reproducibility in postoperative muscle measures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721231202539","type":"journal-article","created":{"date-parts":[[2023,9,19]],"date-time":"2023-09-19T02:23:21Z","timestamp":1695090201000},"page":"656-665","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":6,"title":["Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy in localizing horizontal rectus muscle insertions"],"prefix":"10.1177","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5605-9974","authenticated-orcid":false,"given":"Rui","family":"Duan","sequence":"first","affiliation":[{"name":"Central South University, Aier School of Ophthalmology, Changsha, China"},{"name":"Lanzhou University First Affiliated Hospital, Gansu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiwen","family":"Yang","sequence":"additional","affiliation":[{"name":"Central South University, Aier School of Ophthalmology, Changsha, China"},{"name":"Liaoning Aier Eye Hospital, Shenyang, Liaoning, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2023,9,18]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.170.4.9530066"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)71194-8"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.02-0112"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1067\/mpa.2002.122365"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-7752"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2011-300960"},{"key":"e_1_3_3_8_2","first-page":"756","article-title":"A study of panoramic ultrasound biomicroscopy and anterior segment optical coherence tomography measurements of the horizontal Rectus muscle insertion in strabismus","volume":"22","author":"Duan R","year":"2020","unstructured":"Duan R, Yang J, Liu J. A study of panoramic ultrasound biomicroscopy and anterior segment optical coherence tomography measurements of the horizontal Rectus muscle insertion in strabismus. Chin J Optom Ophthalmol Vis Sci 2020; 22: 756\u2013763.","journal-title":"Chin J Optom Ophthalmol Vis Sci"},{"key":"e_1_3_3_9_2","first-page":"108","article-title":"An anatomical reevaluation of rectus muscle insertions","volume":"13","author":"Apt L","year":"1982","unstructured":"Apt L, Call NB. An anatomical reevaluation of rectus muscle insertions. Ophthalmic Surg 1982; 13: 108\u2013112.","journal-title":"Ophthalmic Surg"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.8.1179"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ohc.2003.12.001"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.oftal.2016.05.004"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.3109\/09273972.2015.1025987"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2006.01.209"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2007.06.019"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2017.07.209"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.01.025"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.4103\/kjo.kjo_32_17"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2015.03.012"},{"key":"e_1_3_3_20_2","doi-asserted-by":"crossref","first-page":"212.e211","DOI":"10.1016\/j.jaapos.2021.03.007","article-title":"Comparison of the swept-source anterior segment optical coherence tomography and wide-field ultrasound biomicroscopy for imaging previously operated horizontal extraocular muscles","volume":"25","author":"Kaur S","year":"2021","unstructured":"Kaur S, Sukhija J, Korla S, et al. Comparison of the swept-source anterior segment optical coherence tomography and wide-field ultrasound biomicroscopy for imaging previously operated horizontal extraocular muscles. J AAPOS: Off Publ Am Assoc Pediatr Ophthalmol Strabismus 2021; 25: 212.e211\u2013212.e216.","journal-title":"J AAPOS: Off Publ Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1080\/2576117X.2022.2026732"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/01913913-20200910-01"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/01913913-20191115-01"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2017.89"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.08.066"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721231202539","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721231202539","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721231202539","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:45:32Z","timestamp":1777405532000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721231202539"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,18]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["10.1177\/11206721231202539"],"URL":"https:\/\/doi.org\/10.1177\/11206721231202539","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,18]]}}}