{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:19:12Z","timestamp":1791332352332,"version":"4.3.1"},"reference-count":39,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2023,11,15]],"date-time":"2023-11-15T00:00:00Z","timestamp":1700006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:p>The efficacy and safety of Descemet's membrane endothelial keratoplasty (DMEK) and ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) have been recently compared in several systematic reviews (SRs). The aim of this study was to assess the evidence quality of such SRs, in order to obtain a scientifically rigorous comparison between the two techniques. We performed a systematic review of SRs and meta-analyses comparing the efficacy and safety between UT-DSAEK and DMEK up to 24th March 2023, using 3 electronic databases (PubMed, Cochrane Library, Google Scholar) plus manual reference search. Specific outcomes analyzed included best-corrected visual acuity (BCVA), endothelial cell density (ECD), rebubbling rate, and other postoperative complications. Of 90 titles\/abstracts screened, four SRs met the inclusion criteria. All SRs adequately analyzed potential bias of the included studies. One SR raised concern for potential literature search bias and two SRs have heterogeneity in some outcomes analyzed. All SRs found higher BCVA after DMEK, but one SR reported significant heterogeneity. All SRs found significant heterogeneity in ECD analysis, with one SR providing inconsistent analysis of this outcome. Three SRs analyzed rebubbling rates, favoring UT-DSAEK over DMEK. Three SRs concluded a higher overall complication rate after DMEK, although rebubbling may be a confounding factor. This systematic review clarifies the strengths and weaknesses of published SRs and reinforces the conclusion that DMEK leads to superior visual outcomes compared to UT-DSAEK, with the trade-off of higher rebubbling rates and possibly other postoperative complications. Studies with longer follow-up are needed to ascertain these differences between procedures.<\/jats:p>","DOI":"10.1177\/11206721231214605","type":"journal-article","created":{"date-parts":[[2023,11,15]],"date-time":"2023-11-15T03:16:01Z","timestamp":1700018161000},"page":"913-923","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Ultrathin DSAEK versus DMEK \u2013 Review of systematic reviews"],"prefix":"10.1177","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5176-1411","authenticated-orcid":false,"given":"Nuno","family":"Moura-Coelho","sequence":"first","affiliation":[{"name":"Cornea and Refractive Surgery Unit, Instituto de Microcirug\u00eda Ocular (IMO) Barcelona Grupo Miranza, Barcelona, Spain"},{"name":"NOVA Medical School (NMS) - Universidade Nova de Lisboa, Lisbon, Portugal"},{"name":"European School for Advanced Studies in Ophthalmology (ESASO), Lugano, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3623-6440","authenticated-orcid":false,"given":"Renato","family":"Papa-Vettorazzi","sequence":"additional","affiliation":[{"name":"Cornea and Refractive Surgery Unit, Instituto de Microcirug\u00eda Ocular (IMO) Barcelona Grupo Miranza, Barcelona, Spain"},{"name":"Anterior Segment Unit, Cl\u00ednica Visualiza Guatemala, Guatemala, Guatemala"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alonso","family":"Reyes","sequence":"additional","affiliation":[{"name":"Cornea and Refractive Surgery Unit, Instituto de Microcirug\u00eda Ocular (IMO) Barcelona Grupo Miranza, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o Paulo","family":"Cunha","sequence":"additional","affiliation":[{"name":"Ophthalmology, Hospital CUF Cascais, Lisbon, Portugal"},{"name":"Escola Superior de Tecnologia da Sa\u00fade de Lisboa (ESTeSL), Lisbon, Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 Luis","family":"G\u00fcell","sequence":"additional","affiliation":[{"name":"Cornea and Refractive Surgery Unit, Instituto de Microcirug\u00eda Ocular (IMO) Barcelona Grupo Miranza, Barcelona, Spain"},{"name":"European School for Advanced Studies in Ophthalmology (ESASO), Lugano, Switzerland"},{"name":"Ophthalmology, Universidad Aut\u00f3noma de Barcelona, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2023,11,15]]},"reference":[{"key":"bibr1-11206721231214605","unstructured":"Eye Bank Association of America. 2021 Eye Banking Statistical Report."},{"key":"bibr2-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1177\/1120672118757431"},{"key":"bibr3-11206721231214605","volume":"6","author":"Stuart AJ","year":"2018","journal-title":"Cochrane Database Syst Rev"},{"key":"bibr4-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.08.015"},{"key":"bibr5-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.04.005"},{"key":"bibr6-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.03.050"},{"key":"bibr7-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2020-316478"},{"key":"bibr8-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2020-317041"},{"key":"bibr9-11206721231214605","volume":"10","author":"Moura-Coelho N","year":"2021","journal-title":"Journal of EuCornea"},{"key":"bibr10-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2012.11.030"},{"key":"bibr11-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001510"},{"key":"bibr12-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2022.09.013"},{"key":"bibr13-11206721231214605","doi-asserted-by":"publisher","DOI":"10.21873\/invivo.13092"},{"key":"bibr14-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1177\/25158414221147823"},{"key":"bibr15-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-023-02467-2"},{"key":"bibr16-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.02.029"},{"key":"bibr17-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.05.019"},{"key":"bibr18-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.12.021"},{"key":"bibr19-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002601"},{"key":"bibr20-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001697"},{"key":"bibr21-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-020-00191-6"},{"key":"bibr22-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2020-000546"},{"key":"bibr23-11206721231214605","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10030419"},{"key":"bibr24-11206721231214605","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1136\/bjophthalmol-2019-315180","volume":"104","author":"Tourabaly M","year":"2020","journal-title":"Br J Ophthalmol"},{"key":"bibr25-11206721231214605","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10215119"},{"key":"bibr26-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2015.06.005"},{"key":"bibr27-11206721231214605","volume-title":"Partnership between Cochrane eyes and vision and the American Academy of Ophthalmology to identify systematic review evidence for clinical practice guidelines","author":"Golozar A"},{"key":"bibr28-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-017-0561-9"},{"key":"bibr29-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2019.1063"},{"key":"bibr30-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2019.4016"},{"key":"bibr31-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2019.02.007"},{"key":"bibr32-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001999"},{"key":"bibr33-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-022-02362-2"},{"key":"bibr34-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.03.011"},{"key":"bibr35-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.09.023"},{"key":"bibr36-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2016.08.038"},{"key":"bibr37-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.12.017"},{"key":"bibr38-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2018.09.033"},{"key":"bibr39-11206721231214605","doi-asserted-by":"publisher","DOI":"10.1111\/aos.15280"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721231214605","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721231214605","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721231214605","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:45:46Z","timestamp":1777405546000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721231214605"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,15]]},"references-count":39,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,7]]}},"alternative-id":["10.1177\/11206721231214605"],"URL":"https:\/\/doi.org\/10.1177\/11206721231214605","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,15]]}}}