{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:47:18Z","timestamp":1777582038361,"version":"3.51.4"},"reference-count":8,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2025,3,23]],"date-time":"2025-03-23T00:00:00Z","timestamp":1742688000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To report an unusual case of scleral burn during Transscleral Diode Laser Cyclophotocoagulation (TDLC) caused by pigment on the laser probe tip.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case Report<\/jats:title>\n                    <jats:p>A 56-year-old man underwent TDLC for severe glaucoma refractory to conventional treatments. During the procedure, he developed a scleral burn attributed to pigment on the laser probe tip. The burn healed spontaneously with topical treatment alone, highlighting the potential for scleral tissue to heal remarkably without further surgical intervention.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This case report underscores the importance of vigilance during TDLC procedures and careful management of potential pigment sources to prevent scleral damage.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721251327643","type":"journal-article","created":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T02:39:29Z","timestamp":1742783969000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Enhancing safety of transscleral diode cyclophotocoagulation: Check the tip before use"],"prefix":"10.1177","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2614-0234","authenticated-orcid":false,"given":"Francesco","family":"Matarazzo","sequence":"first","affiliation":[{"name":"Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples \u201cFederico II\u201d, Naples, Italy"},{"name":"Department of Physics \u201cEttore Pancini\u201d, University of Naples \u201cFederico II\u201d, Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soledad","family":"Aguilar-Munoa","sequence":"additional","affiliation":[{"name":"Glaucoma Service, Moorfields Eye Hospital NHS Foundation Trust, London, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleni","family":"Nikita","sequence":"additional","affiliation":[{"name":"Glaucoma Service, Moorfields Eye Hospital NHS Foundation Trust, London, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,3,23]]},"reference":[{"key":"e_1_3_2_2_2","article-title":"Cyclodestructive procedures for refractory glaucoma","volume":"3","author":"Chen MF","year":"2019","unstructured":"Chen MF, Kim CH, Coleman AL. Cyclodestructive procedures for refractory glaucoma. Cochrane Database Syst Rev 2019; 3: CD012223.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_3_2","article-title":"Cyclodestructive procedures for non-refractory glaucoma","volume":"4","author":"Michelessi M","year":"2018","unstructured":"Michelessi M, Bicket AK, Lindsley K. Cyclodestructive procedures for non-refractory glaucoma. Cochrane Database Syst Rev 2018; 4: CD009313.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajoc.2023.101893"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30109-2"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.83.4.501c"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1542-8877-19970601-09"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702179"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2007.01466.x"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251327643","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721251327643","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251327643","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:47:21Z","timestamp":1777405641000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721251327643"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,23]]},"references-count":8,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1177\/11206721251327643"],"URL":"https:\/\/doi.org\/10.1177\/11206721251327643","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,23]]}}}