{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:18:08Z","timestamp":1777580288041,"version":"3.51.4"},"reference-count":20,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T00:00:00Z","timestamp":1742860800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>This study aimed to assess whether semi-automated kinetic perimetry (SKP) enables the quantitation and monitoring of visual field loss in persons with idiopathic intracranial hypertension (PWIIH).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We conducted a retrospective review of newly diagnosed PWIIH. We recorded baseline clinical data and optic disc modified Fris\u00e9n grade from fundal photographs. The SKP software calculated the I4e and I2e isopter areas and the I4e target plotted blind spot areas. This was recorded for each eye at baseline and for each study visit for up to 1 year.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Both the baseline I4e isopter (F\u2009=\u200944.1,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) and I2e isopter areas (F\u2009=\u200937.1,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) were significantly related to baseline visual acuity. The baseline blind spot area was significantly related to modified Fris\u00e9n grade (F\u2009=\u200922.0,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). There was no significant linear relationship between either the I4e isopter (F\u2009=\u20090.06;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.939) or I2e isopter areas (F\u2009=\u20090.06,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.807) and the time since diagnosis. There was, however a significant linear decrease in mean blind spot area over time (F\u2009=\u200946.6,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The relationships at baseline between I4e and I2e isopter areas and visual acuity show that SKP provides clinically meaningful results at presentation in PWIIH. Our results suggest that it is less useful for monitoring recovery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721251329982","type":"journal-article","created":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T17:11:01Z","timestamp":1742922661000},"page":"1761-1766","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluating semi-automated kinetic perimetry in persons with idiopathic intracranial hypertension"],"prefix":"10.1177","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1003-4370","authenticated-orcid":false,"given":"Simon J.","family":"Hickman","sequence":"first","affiliation":[{"name":"Department of Neurology, Royal Hallamshire Hospital, Sheffield, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucy","family":"Givens","sequence":"additional","affiliation":[{"name":"School of Medicine and Population Health, University of Sheffield, Sheffield, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joanna M.","family":"Jefferis","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Royal Hallamshire Hospital, Sheffield, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Irene M.","family":"Pepper","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Royal Hallamshire Hospital, Sheffield, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin J.","family":"Rhodes","sequence":"additional","affiliation":[{"name":"Department of Orthoptics, Royal Hallamshire Hospital, Sheffield, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,3,25]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.2174\/1874364101307010026"},{"key":"e_1_3_2_3_2","doi-asserted-by":"crossref","DOI":"10.3171\/FOC-07\/11\/E5","article-title":"Mechanisms of visual loss in papilledema","volume":"23","author":"Schirmer CM","year":"2007","unstructured":"Schirmer CM, Hedges TR3rd. Mechanisms of visual loss in papilledema. Neurosurg Focus 2007; 23: E5.","journal-title":"Neurosurg Focus"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/WNO.0000000000001902"},{"key":"e_1_3_2_5_2","volume-title":"Neuropathology of vision","author":"Lindenberg R","year":"1973","unstructured":"Lindenberg R, Walsh FB, Sacks JG. Neuropathology of vision. Philadelphia, USA: Lea & Febiger, 1973."},{"key":"e_1_3_2_6_2","first-page":"155","article-title":"Idiopathic intracranial hypertension. A prospective study of 50 patients","volume":"114","author":"Wall M","year":"1991","unstructured":"Wall M, George D. Idiopathic intracranial hypertension. A prospective study of 50 patients. Brain 1991; 114: 155\u2013180.","journal-title":"Brain"},{"key":"e_1_3_2_7_2","doi-asserted-by":"crossref","first-page":"1898","DOI":"10.1167\/iovs.18-26252","article-title":"Threshold static automated perimetry of the full visual field in idiopathic intracranial hypertension","volume":"60","author":"Wall M","year":"2019","unstructured":"Wall M, Subramani A, Chong LX, et al. Threshold static automated perimetry of the full visual field in idiopathic intracranial hypertension. Invest Ophthalmol Vis Sci 2019; 60: 1898\u20131905.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/214829"},{"key":"e_1_3_2_9_2","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1167\/iovs.16-19868","article-title":"Reclaiming the periphery: automated kinetic perimetry for measuring peripheral visual fields in patients with glaucoma","volume":"58","author":"M\u00f6nter VM","year":"2017","unstructured":"M\u00f6nter VM, Crabb DP, Artes PH. Reclaiming the periphery: automated kinetic perimetry for measuring peripheral visual fields in patients with glaucoma. Invest Ophthalmol Vis Sci 2017; 58: 868\u2013875.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_10_2","doi-asserted-by":"crossref","DOI":"10.1111\/aos.13940","article-title":"Semi-automated kinetic perimetry: comparison of the Octopus 900 and Humphrey visual field analyzer 3 versus Goldmann perimetry","volume":"97","author":"Bevers C","year":"2019","unstructured":"Bevers C, Blanckaert G, Van Keer K, et al. Semi-automated kinetic perimetry: comparison of the Octopus 900 and Humphrey visual field analyzer 3 versus Goldmann perimetry. Acta Ophthalmol 2019; 97: e499\u2013e505.","journal-title":"Acta Ophthalmol"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2005.00624.x"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e31814b9985"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1212\/01.WNL.0000029570.69134.1B"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2010.94"},{"key":"e_1_3_2_15_2","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1038\/sj.eye.6700168","article-title":"Vigabatrin associated visual field loss: a clinical audit to study prevalence, drug history and effects of drug withdrawal","volume":"16","author":"Newman WD","year":"2002","unstructured":"Newman WD, Tocher K, Acheson JF. Vigabatrin associated visual field loss: a clinical audit to study prevalence, drug history and effects of drug withdrawal. Eye 2002; 16: 567\u2013571.","journal-title":"Eye"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3109\/01658107.2014.956183"},{"key":"e_1_3_2_17_2","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.1038\/s41433-020-1024-8","article-title":"Optic nerve sheath fenestration via supero-medial eyelid skin crease approach for the treatment of idiopathic intracranial hypertension in a UK population","volume":"35","author":"Jefferis JM","year":"2021","unstructured":"Jefferis JM, Littlewood RA, Pepper IM, et al. Optic nerve sheath fenestration via supero-medial eyelid skin crease approach for the treatment of idiopathic intracranial hypertension in a UK population. Eye 2021; 35: 1418\u20131426.","journal-title":"Eye"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1093\/braincomms\/fcab202"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/WNO.0000000000000327"},{"key":"e_1_3_2_20_2","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1167\/iovs.15-18626","article-title":"Visual field outcomes for the Idiopathic Intracranial Hypertension Treatment Trial (IIHTT)","volume":"57","author":"Wall M","year":"2016","unstructured":"Wall M, Johnson CA, Cello KE, et al. Visual field outcomes for the Idiopathic Intracranial Hypertension Treatment Trial (IIHTT). Invest Ophthalmol Vis Sci 2016; 57: 805\u2013812.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/03331024231197118"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251329982","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721251329982","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251329982","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:41:06Z","timestamp":1777405266000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721251329982"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,25]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1177\/11206721251329982"],"URL":"https:\/\/doi.org\/10.1177\/11206721251329982","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,25]]}}}