{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T20:18:23Z","timestamp":1777580303960,"version":"3.51.4"},"reference-count":10,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T00:00:00Z","timestamp":1747699200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>\n                      To present the correct placement of the Ex-PRESS\n                      <jats:sup>\u00ae<\/jats:sup>\n                      implant in the anterior chamber with the intraoperative optical coherence tomography (i-OCT) scan. To the best of our knowledge, this is the first publication to report the use of i-OCT during an Ex-PRESS\n                      <jats:sup>\u00ae<\/jats:sup>\n                      glaucoma implant procedure.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Case report<\/jats:title>\n                    <jats:p>\n                      We report the case of a phakic, 48 year-old South American male with bilateral advanced pigmentary glaucoma. Our patient was being treated with dorzolamide-timolol eyedrops twice daily and bimatoprost eyedrops once daily in both eyes. Glaucomatous damage in his left eye had progressed and it was then decided to perform filtering surgery in our patient\u00b4s left eye, using a P-50 Ex-PRESS\n                      <jats:sup>\u00ae<\/jats:sup>\n                      shunt and two Ologen\n                      <jats:sup>\u00ae<\/jats:sup>\n                      collagen matrix implants. As our patient was phakic, special care was taken to avoid contact with the lens. The correct placement of both subscleral devices was confirmed with the OPMI LUMERA\n                      <jats:sup>\u00ae<\/jats:sup>\n                      700 microscope, an i-OCT device. i-OCT scans as well as a video recording were performed throughout the surgical procedure.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>I-Oct can help surgeons to locate the correct placement of implants in cases such as corneal opacification or gerontoxon. This instrument is helpful in the training of ophthalmologists. I-OCT can help surgeons to locate the correct placement of implants in cases with media opacity (such as corneal opacification or gerontoxon) or in phakic patients, where it is important to avoid lens contact. This instrument is helpful in the training of ophthalmologists.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721251340295","type":"journal-article","created":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T10:57:57Z","timestamp":1747738677000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Intraoperative optical coherence tomography in glaucoma surgery with Ex-PRESS\n                    <sup>\u00ae<\/sup>\n                    implant"],"prefix":"10.1177","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-0128-9278","authenticated-orcid":false,"given":"Irene","family":"Platas Moreno","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Hospital Universitario Fundacion Jimenez Diaz, Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Guerrero Altares","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Universitario Fundacion Jimenez Diaz, Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M Pilar","family":"Martin-Gutierrez","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Universitario Fundacion Jimenez Diaz, Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ignacio Jim\u00e9nez-Alfaro","family":"Morote","sequence":"additional","affiliation":[{"name":"Chief of Ophthalmology, Hospital Universitario Fundacion Jimenez Diaz and Hospitales Publicos de QuironSalud, Madrid, Spain"},{"name":"Member of IIS-FJD (Instituto de Investigacion Sanitaria del Hospital Universitario Fundacion Jimenez Diaz), Madrid, Spain"},{"name":"Professor of Ophthalmology, Universidad Autonoma de Madrid (UAM), Madrid, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,5,20]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.11.019"},{"key":"e_1_3_2_3_2","article-title":"Anterior segment imaging in minimally invasive glaucoma surgery \u2013 A systematic review","volume":"100","author":"Tsia-Chuen Kan J","year":"2022","unstructured":"Tsia-Chuen Kan J, Kaijun Betzler B, Yang Lim S, et al. Anterior segment imaging in minimally invasive glaucoma surgery \u2013 A systematic review. Acta Ophthalmol 2022 May; 100(3): e617\u2013e634.","journal-title":"Acta Ophthalmol"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0689-3"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2017.4431"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S145873"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2014.995311"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0447-6"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.4103\/2008-322X.194150"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2019.09.018"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3182019c18"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251340295","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721251340295","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251340295","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T19:41:19Z","timestamp":1777405279000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721251340295"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,20]]},"references-count":10,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1177\/11206721251340295"],"URL":"https:\/\/doi.org\/10.1177\/11206721251340295","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,20]]}}}