{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T09:09:05Z","timestamp":1784020145184,"version":"3.55.0"},"reference-count":32,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare the refractive outcomes and rotational stability between a plate-haptic toric intraocular lens (IOL) and a C-loop haptic toric IOL in cataract eyes with corneal astigmatism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This was a prospective, randomised, controlled study. 72 patients (72 eyes) with cataracts and corneal astigmatism were randomly divided into 2 groups (Group A: C-loop haptic; Group B: plate-haptic) and underwent phacoemulsification combined with toric IOL implantation at Changzhou Third People's Hospital. The uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA) and residual astigmatism (RAS) were assessed at 1 day, 1 week, 1 month, 3 months postoperatively, while the degree of toric IOL rotation was recorded at 1 week, 1 month, 3 months postoperatively. The correlation between IOL rotation and RAS, intraocular pressure (IOP), axial length (AL), anterior chamber depth (ACD), and white-to-white (WTW) distance was analyzed. Patient satisfaction was evaluated in both groups 3 months postoperatively. Independent sample\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test was used for comparison between the two groups, and repeated measures analysis of variance (ANOVA) was employed to assess changes in IOL rotation, RAS and visual acuity at various postoperative time points. Pearson correlation analysis was used to assess the relationships between continuous variables.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 72 eyes (36 per group) were included with no significant difference in patient characteristics between the two groups. The average postoperative degree of toric IOL rotation in Group A at 1-week, 1-month, and 3-month was greater than that in Group B (8.38\u2009\u00b1\u20094.19\u00b0vs 4.45\u2009\u00b1\u20092.40\u00b0, 7.78\u2009\u00b1\u20096.87\u00b0vs 3.95\u2009\u00b1\u20092.14\u00b0, and 8.23\u2009\u00b1\u20094.72\u00b0vs 4.09\u2009\u00b1\u20092.12\u00b0, respectively, all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.05). Postoperative RAS and spherical equivalent (SE) were better in Group B than Group A (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.05). More patients in Group B achieved RAS within 0.50D than in Group A (23 vs 14). RAS was positively correlated with IOL rotation in both groups. Patients in Group B achieved a better UDVA than in Group A, whereas no statistical difference in BDVA was found between groups. No significant correlations were found between toric IOL rotation and IOP, AL, ACD, and WTW distance either in Group A or Group B (all\n                      <jats:italic toggle=\"yes\">P\u2009<\/jats:italic>\n                      &gt;\n                      <jats:italic toggle=\"yes\">\u2009<\/jats:italic>\n                      0.05). Patient satisfaction was referred as high or very high by 75.0% of patients in Group B compared to 50.0% in Group A. More patients in Group B gained distance spectacle independence than Group A (20 vs 10). No eye-threatening complications were observed intraoperatively or postoperatively. No patients required IOL repositioning during follow-up.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The plate-haptic toric IOL demonstrated superior rotational stability and astigmatism correction than C-loop haptic toric IOL within 3 months postoperatively, which implied that the plate-haptic toric IOL might be a better choice for patients with cataract and corneal astigmatism.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721251349041","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T03:32:31Z","timestamp":1749180751000},"page":"1992-2000","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of clinical outcomes and capsular bag stability between plate-haptic and C-loop haptic toric IOLs in cataract eyes"],"prefix":"10.1177","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-5193-1100","authenticated-orcid":false,"given":"Xin","family":"Gao","sequence":"first","affiliation":[{"name":"Changzhou Third People's Hospital"},{"name":"Changzhou School of Clinical Medicine, Nanjing Medical University, Changzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Zhou","sequence":"additional","affiliation":[{"name":"Changzhou Third People's Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Jiang","sequence":"additional","affiliation":[{"name":"Changzhou Third People's Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhinan","family":"Liu","sequence":"additional","affiliation":[{"name":"Changzhou Third People's Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Zhang","sequence":"additional","affiliation":[{"name":"Changzhou Third People's Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0804-1117","authenticated-orcid":false,"given":"Guohua","family":"Deng","sequence":"additional","affiliation":[{"name":"Changzhou Third People's Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.4103\/IJO.IJO_3403_22"},{"key":"e_1_3_2_3_2","first-page":"7","article-title":"Consensus of the Chinese experts on the clinical application of astigmatic intraocular lenses (2017)","volume":"53","author":"GROUP COSCAIL","year":"2017","unstructured":"GROUP COSCAIL. Consensus of the Chinese experts on the clinical application of astigmatic intraocular lenses (2017). Chin J Ophthalmol 2017; 53 : 7\u201310.","journal-title":"Chin J Ophthalmol"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1080\/08820538.2019.1607399"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000259"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.04.041"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.10.002"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.049"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000259"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130129-02"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-8-8"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90504-3"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1993.01090060119035"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00797-5"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(99)80231-1"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.04.036"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e328011f9bf"},{"key":"e_1_3_2_18_2","first-page":"138","article-title":"Refractive outcomes for cataract surgery with toric intraocular lenses at a veterans affairs medical center","volume":"37","author":"Tran EM","year":"2020","unstructured":"Tran EM, Tang KS, Chen AJ, et al. Refractive outcomes for cataract surgery with toric intraocular lenses at a veterans affairs medical center. Fed Pract 2020; 37: 138\u2013142.","journal-title":"Fed Pract"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2010.00515.x"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.01.037"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.12.024"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-023-06232-9"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_73_18"},{"key":"e_1_3_2_24_2","first-page":"105","article-title":"Observation of complications at the operative and early postoperative stages of phacoemulsification","volume":"14","author":"Zheng D","unstructured":"Zheng D, Liu Y. Observation of complications at the operative and early postoperative stages of phacoemulsification. Yan Ke Xue Bao 1998 Jun; 14: 105\u2013107. 104. Chinese. PMID: 12580045.","journal-title":"Yan Ke Xue Bao"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130129-02"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.07.043"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.04.057"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.04.009"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2018.0041"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.05.015"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-306656"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0521-0"},{"key":"e_1_3_2_33_2","first-page":"41","article-title":"The rotational stability of Toric intraocular lenses and influencing factors in cataract patients with different axial length[J]","volume":"56","author":"Gao YF","year":"2020","unstructured":"Gao YF, Sun T, Luo JH, et al. The rotational stability of Toric intraocular lenses and influencing factors in cataract patients with different axial length[J]. Chin J Ophthalmol 2020; 56: 41\u201346.","journal-title":"Chin J Ophthalmol"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251349041","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721251349041","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721251349041","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T08:54:55Z","timestamp":1784019295000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721251349041"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1177\/11206721251349041"],"URL":"https:\/\/doi.org\/10.1177\/11206721251349041","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,6]]}}}