{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T02:50:43Z","timestamp":1781923843285,"version":"3.54.5"},"reference-count":37,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T00:00:00Z","timestamp":1771459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["European Journal of Ophthalmology"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate whether an algorithm that quantifies changes in hemoglobin (Hb) concentration in the optic nerve head (ONH) can detect progression in glaucomatous eyes with progressive visual field changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective cohort study involved eyes with primary open-angle glaucoma (POAG). Eyes were required to have at least five Standard Automated Perimetry (SAP) tests and three ONH photos during follow-up. ONH photos were processed using the Laguna ONhE software (Retinalyze, Spain). The software estimates Hb concentration at the ONH using automated colorimetric analysis. Visual field progression was defined based on the event-based algorithm provided by the guided progression analysis (GPA) software of the Humphrey perimeter. Changes in Hb levels from fundus photos during follow-up were calculated and receiver operating characteristic curve (ROC) regression models were used to assess the performance of Globin Individual Pointer (GIP) changes as an indicator of glaucomatous visual field progression.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      133 eyes of 102 subjects were included in the study, with 26 (20%) eyes demonstrating progression by the SAP GPA over an average follow-up time of 2.4\u2009\u00b1\u20091.6 years. The median (IQR) change in SAP mean deviation (MD) between the first and last visits was \u22122.20 (\u22124.65 to \u22120.62) dB in progressing and \u22120.01 (\u22121.17 to 1.03) dB in non-progressing eyes (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.010). Progressing eyes had a median change of \u22124.9 (IQR: \u221210.4 to 3.1) GIP units, compared to \u22121.6 (IQR: \u221211.2 to 7.8) units for non-progressing eyes (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.288). A statistically significant negative GIP slope (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.05) was observed in two (7.7%) of the progressing eyes and 14 (13.1%) of the non-progressing eyes. Each 10-unit decrease in GIP during follow-up was associated with a 22% increase in the odds of progressing by GPA (OR: 1.22; 95% CI: 0.98\u20131.52;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.071), whereas a 10 unit\/year faster slope was associated with 6% higher odds of visual field progression (OR: 1.06; 95% CI: 0.90\u20131.26;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009=\u20090.456). The area under the ROC curve to detect progression based on GIP change was 0.49 (95% CI: 0.39\u20130.60).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Reductions in Hb concentration estimates from fundus photos were not significantly different between progressing and non-progressing eyes. GIP changes overtime were not associated with visual field progression. We believe that the ability to detect glaucoma progression with this method requires improvement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11206721261424634","type":"journal-article","created":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T18:05:41Z","timestamp":1771524341000},"page":"925-934","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Detecting glaucoma progression through optic nerve head hemoglobin concentration using automated colorimetric analysis"],"prefix":"10.1177","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-3057-8972","authenticated-orcid":false,"given":"Ver\u00f4nica","family":"Vilasboas-Campos","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, University of Campinas"},{"name":"Bascom Palmer Eye Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5341-8353","authenticated-orcid":false,"given":"Alessandro A.","family":"Jammal","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Campinas"},{"name":"Bascom Palmer Eye Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2943-2803","authenticated-orcid":false,"given":"Gabriel","family":"Ayub","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Campinas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8220-6675","authenticated-orcid":false,"given":"Jos\u00e9 Paulo C.","family":"Vasconcellos","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Campinas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6147-4611","authenticated-orcid":false,"given":"Vital P.","family":"Costa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Campinas"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,2,19]]},"reference":[{"key":"e_1_3_4_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(04)16257-0"},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2014.3192"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.03.019"},{"key":"e_1_3_4_5_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-3468"},{"key":"e_1_3_4_6_2","unstructured":"Vessani RM G C Leite M. Guidelines for using OCT for glaucoma. Soc Bras Glaucoma. In: Glaucoma SB ed. 2019."},{"key":"e_1_3_4_7_2","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.003127"},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2015.1062112"},{"key":"e_1_3_4_9_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-15592"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-10761"},{"key":"e_1_3_4_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.12.062"},{"key":"e_1_3_4_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2007.08.001"},{"key":"e_1_3_4_13_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-0227"},{"key":"e_1_3_4_14_2","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/2340236"},{"key":"e_1_3_4_15_2","unstructured":"M. GdlR. Laguna OhNE User Manual. Instrumentacion y Oftalmolog\u00eda (INSOFT S.L.). Version 6.0. July 2022."},{"key":"e_1_3_4_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000002026"},{"key":"e_1_3_4_17_2","first-page":"212","article-title":"Correlating cup- to-disc ratios measured by HRT-III, SD-OCT and the new color imaging Laguna ONhE procedure","volume":"90","author":"Rodr\u00edguez U\u00f1a I","year":"2015","unstructured":"Rodr\u00edguez U\u00f1a I, Hern\u00e1ndez CDM, S\u00e1enz-Franc\u00e9s F, et al. Correlating cup- to-disc ratios measured by HRT-III, SD-OCT and the new color imaging Laguna ONhE procedure. Arch Soc Esp Oftalmol 2015; 90: 212\u2013219.","journal-title":"Arch Soc Esp Oftalmol"},{"key":"e_1_3_4_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.13050"},{"key":"e_1_3_4_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000000160"},{"key":"e_1_3_4_20_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-03549-9"},{"key":"e_1_3_4_21_2","article-title":"New GIP index for progression analysis, ussing the laguna Onhe method for the optic nerve head hemoglobin evaluation","volume":"62","author":"Gonzalez-Hernandez M","unstructured":"Gonzalez-Hernandez M, Gonzalez-Hernandez D, Paloma RE, et al. New GIP index for progression analysis, ussing the laguna Onhe method for the optic nerve head hemoglobin evaluation. Arvo journals June 2021; 62.","journal-title":"Arvo journals"},{"key":"e_1_3_4_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.03.016"},{"key":"e_1_3_4_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/biomet\/73.1.13"},{"key":"e_1_3_4_24_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1441"},{"key":"e_1_3_4_25_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2020-316455"},{"key":"e_1_3_4_26_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12175485"},{"key":"e_1_3_4_27_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12185876"},{"key":"e_1_3_4_28_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11247294"},{"key":"e_1_3_4_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.05.019"},{"key":"e_1_3_4_30_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.15-18940"},{"key":"e_1_3_4_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2012.03.044"},{"key":"e_1_3_4_32_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-018-3963-3"},{"key":"e_1_3_4_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.10.029"},{"key":"e_1_3_4_34_2","doi-asserted-by":"publisher","DOI":"10.1117\/1.2774827"},{"key":"e_1_3_4_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.05.022"},{"key":"e_1_3_4_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e318259b2e1"},{"key":"e_1_3_4_37_2","first-page":"122","article-title":"Measurement of retinal thickness in macular region of high myopic eyes using spectral domain OCT","volume":"7","author":"Song AP","year":"2014","unstructured":"Song AP, Wu XY, Wang JR, et al. Measurement of retinal thickness in macular region of high myopic eyes using spectral domain OCT. Int J Ophthalmol 2014; 7: 122\u2013127. doi:10.3980\/j.issn.2222-3959.2014.01.23","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_4_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.08.019"}],"container-title":["European Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721261424634","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11206721261424634","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11206721261424634","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T02:02:09Z","timestamp":1781920929000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11206721261424634"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,19]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1177\/11206721261424634"],"URL":"https:\/\/doi.org\/10.1177\/11206721261424634","relation":{},"ISSN":["1120-6721","1724-6016"],"issn-type":[{"value":"1120-6721","type":"print"},{"value":"1724-6016","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,19]]}}}