{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T23:13:17Z","timestamp":1777677197301,"version":"3.51.4"},"reference-count":31,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T00:00:00Z","timestamp":1750982400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"GCS Ramsay Sant\u00e9 pour l\u2019Enseignement et la Recherche"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["HIP International"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To determine: (1) the prevalence of articular noise in primary ceramic-on-ceramic (CoC) total hip arthroplasty (THA) using 2 different designs of short uncemented stems; (2) risk factors for noise; and (3) the impact of noise on quality of life (QoL), at a minimum follow-up of 5\u2009years.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>70 patients (81 hips) that underwent primary CoC THA with either SMS or Minimax stems (Medacta, Switzerland) between 01 February 2015 and 31 December 2017 were retrospectively reviewed. Clinical assessment included Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), modified Harris Hip Score (mHHS), and a questionnaire on articular noise. Regression analyses were performed to find associations with articular noise.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      64 patients (74 hips; 40 SMS, 34 Minimax) were available for clinical assessment at \u2a7e5\u2009years. There were no significant differences between the SMS and Minimax groups in terms of postoperative WOMAC (93.5\u2009\u00b1\u20096.7 vs. 90.9\u2009\u00b1\u200911.8,\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.746) and mHHS (94.9\u2009\u00b1\u200912.7 vs. 95.7\u2009\u00b1\u20099.7,\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.641). The prevalence of articular noise was 23% (9 hips) in the SMS group and 24% (8 hips) in the Minimax group (\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20091.000). Regression analyses revealed that presence of noise was associated with preoperative WOMAC (OR 1.05; 95% CI, 1.01\u20131.10;\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.023), and tended to be associated with age (OR 0.96; 95%CI, 0.91\u20131.00;\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.060), cup diameter of 58\u201360\u2009mm (OR 4.43; 95% CI, 0.86\u201323.44;\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.070), and head diameter of 36\u2009mm (OR, 5.29; 95% CI, 0.86\u201338.10;\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.080). Impact of noise on QoL was low for both groups (1.0\u2009\u00b1\u20091.4 vs. 1.3\u2009\u00b1\u20092.2,\n                      <jats:italic toggle=\"yes\">p\u2009=<\/jats:italic>\n                      \u20090.862).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The present study on primary CoC THA reported an overall prevalence of articular noise of 24% for 2 designs of short stems. Clinical outcomes and satisfaction rates were high for most patients, with noise having little impact on QoL and no noise-related clinical complications being observed. Risk factors for articular noise may be better preoperative WOMAC, younger age, and larger femoral head and cup diameter.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11207000251346917","type":"journal-article","created":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T05:43:18Z","timestamp":1751002998000},"page":"563-573","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Prevalence of articular noise in ceramic-on-ceramic total hip arthroplasty with short stems"],"prefix":"10.1177","volume":"35","author":[{"given":"Frederic","family":"Laude","sequence":"first","affiliation":[{"name":"Ramsay Sant\u00e9, Clinique du Sport Paris V, Paris, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"ReSurg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Matar","sequence":"additional","affiliation":[{"name":"Ramsay Sant\u00e9, Clinique du Sport Paris V, Paris, France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0409-613X","authenticated-orcid":false,"given":"Sonia","family":"Ramos-Pascual","sequence":"additional","affiliation":[{"name":"ReSurg SA, Nyon, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bethany","family":"Grew","sequence":"additional","affiliation":[{"name":"ReSurg SA, Nyon, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sonia","family":"Dubreil","sequence":"additional","affiliation":[{"name":"ReSurg SA, Nyon, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mo","family":"Saffarini","sequence":"additional","affiliation":[{"name":"ReSurg SA, Nyon, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2025,6,27]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-021-04055-z"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2021.751121"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2022.103438"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2020.09.009"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02828-1"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.08.027"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.08.076"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2022.12.009"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2018.02.045"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-019-02426-2"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.4103\/ortho.IJOrtho_416_18"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-021-04953-8"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.4055\/cios21048"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2010.12.012"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.01326"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2011.04.031"},{"key":"e_1_3_3_18_2","first-page":"42","article-title":"Ceramic-ceramic hip arthroplasty for osteonecrosis: average 5-year follow-up in patients less than 50 years of age","volume":"73","author":"Evangelista PJ","year":"2015","unstructured":"Evangelista PJ, Kamath AF, Aversano FJ, et al Ceramic-ceramic hip arthroplasty for osteonecrosis: average 5-year follow-up in patients less than 50 years of age. Bull Hosp Jt Dis (2013) 2015; 73: 42\u201345.","journal-title":"Bull Hosp Jt Dis (2013)"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2020.11.012"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.19.01397"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-018-0841-y"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00970"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.10.032"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.95B2.30450"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2022.06.003"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.20.00354"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.22255"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcot.2022.101942"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1051\/sicotj\/2022032"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.artd.2021.11.006"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.4055\/cios21192"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1177\/11207000231198220"}],"container-title":["HIP International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11207000251346917","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11207000251346917","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11207000251346917","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T08:23:20Z","timestamp":1777451000000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11207000251346917"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,27]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1177\/11207000251346917"],"URL":"https:\/\/doi.org\/10.1177\/11207000251346917","relation":{},"ISSN":["1120-7000","1724-6067"],"issn-type":[{"value":"1120-7000","type":"print"},{"value":"1724-6067","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,27]]}}}