{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T23:11:18Z","timestamp":1777936278918,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T00:00:00Z","timestamp":1729728000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Suzhou Gusu Health Talent Plan","award":["GSWS2022129"],"award-info":[{"award-number":["GSWS2022129"]}]},{"name":"Suzhou Science & Technology Plan Project","award":["SKYD2023092"],"award-info":[{"award-number":["SKYD2023092"]}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Vasc Access"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>In this pilot study, we describe a novel technique for creating a snuffbox fistula (SBF) and present the preliminary outcomes after 4\u20136\u2009weeks of follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The study included eight male patients with a mean age of 50\u2009years (range 36\u201366\u2009years). All patients received an SBF using the modified no-touch technique (MNTT) and piggyback straight-line on-lay technique (pSLOT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Immediate patency was obtained for all patients. In one case, a thrombosis developed at the juxta anastomosis. The remaining seven SBFs met the clinical arteriovenous fistula maturity criteria at the physical examination performed 4\u20136\u2009weeks after surgery, showing an easily palpable vein, a straight superficial segment &gt;10\u2009cm in length and a sufficient diameter, and good palpable thrill. In addition, an ultrasound examination showed that the diameter of the drainage vein was 4\u20136\u2009mm, and the brachial blood flow was \u2a7e500\u2009mL\/min.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The combination of MNTT and pSLOT was used to successfully establish SBFs, and the success rate of surgery and access maturity were high.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11297298241292116","type":"journal-article","created":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T11:49:52Z","timestamp":1729770592000},"page":"1754-1759","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["A novel technique for snuffbox fistula creation"],"prefix":"10.1177","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-6524-0820","authenticated-orcid":false,"given":"Xiaohe","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Nephrology, Suzhou Research Center of Medical School, Suzhou Hospital, Affiliated Hospital of Medical School, Nanjing University, Suzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia","family":"Zhi","sequence":"additional","affiliation":[{"name":"Department of Nephrology, Suzhou Research Center of Medical School, Suzhou Hospital, Affiliated Hospital of Medical School, Nanjing University, Suzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1594-3645","authenticated-orcid":false,"given":"Guocun","family":"Hou","sequence":"additional","affiliation":[{"name":"Department of Nephrology, Suzhou Research Center of Medical School, Suzhou Hospital, Affiliated Hospital of Medical School, Nanjing University, Suzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2024,10,24]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1523-1755.2003.00210.x"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.4103\/1319-2442.124554"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/1129729819845562"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.2016121355"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2011.07.090"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvscit.2021.08.015"},{"key":"e_1_3_2_8_2","first-page":"e62784","article-title":"Creating radiocephalic arteriovenous fistula in the forearm with a modified no-touch technique","volume":"182","author":"Yuanyuan Z","year":"2022","unstructured":"Yuanyuan Z, Xiaohe W, Zhen L, et al. Creating radiocephalic arteriovenous fistula in the forearm with a modified no-touch technique. J Vis Exp 2022; 182: e62784.","journal-title":"J Vis Exp"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/11297298221139339"},{"key":"e_1_3_2_10_2","first-page":"714","article-title":"Clinical efficacy of a modified no-touch technique in the establishment of autologous arteriovenous fistula","volume":"103","author":"Xiaohe W","year":"2023","unstructured":"Xiaohe W, Ping D, Zhen L, et al. Clinical efficacy of a modified no-touch technique in the establishment of autologous arteriovenous fistula. Natl Med J China 2023; 103: 714\u2013719.","journal-title":"Natl Med J China"},{"key":"e_1_3_2_11_2","first-page":"112972982412289","article-title":"A modified technique for arteriovenous fistula anastomosis: preserving the surrounding tissue of the vein without the use of vascular clamps","volume":"11","author":"Xiaohe W","year":"2024","unstructured":"Xiaohe W, Jie L, Zhen L, et al. A modified technique for arteriovenous fistula anastomosis: preserving the surrounding tissue of the vein without the use of vascular clamps. J Vasc Access 2024; 11: 11297298241228932.","journal-title":"J Vasc Access"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2008.08.042"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2018.02.001"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/1744-9987.12296"},{"issue":"6","key":"e_1_3_2_15_2","first-page":"365","article-title":"Expert consensus on vascular access for hemodialysis in China","volume":"18","author":"Chinese Hospital Association Blood Purification Center Branch Vascular Access Working Group","year":"2019","unstructured":"Chinese Hospital Association Blood Purification Center Branch Vascular Access Working Group. Expert consensus on vascular access for hemodialysis in China. Chin J Blood Purif 2019; 18(6): 365\u2013381.","journal-title":"Chin J Blood Purif"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2021.12.056"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2015.08.104"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/112972980901000401"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/ki.2013.290"}],"container-title":["The Journal of Vascular Access"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11297298241292116","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11297298241292116","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11297298241292116","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T03:25:32Z","timestamp":1777692332000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11297298241292116"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,24]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1177\/11297298241292116"],"URL":"https:\/\/doi.org\/10.1177\/11297298241292116","relation":{},"ISSN":["1129-7298","1724-6032"],"issn-type":[{"value":"1129-7298","type":"print"},{"value":"1724-6032","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,24]]}}}