{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T07:32:59Z","timestamp":1793863979718,"version":"4.6.1"},"reference-count":28,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Vasc Access"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Peripherally inserted central catheter ports (PICC-ports) are a recent alternative to traditional chest ports for long-term vascular access in oncology. While associated with easier insertion and improved patient comfort, comparative safety data remain limited. Prior meta-analyses were not conclusive as they included patients from older cohorts in whom outdated brachial or arm ports were used. This warrants further studies evaluating the safety profile of PICC-ports in a general cancer population.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods:<\/jats:title>\n                    <jats:p>We conducted a retrospective, single-center study comparing safety of PICC-ports and chest ports in adult oncology patients implanted between August 2022 and November 2024. Patients with contraindications to PICC-ports or receiving continuous infusion chemotherapy were excluded to minimize indication bias. All catheters were placed by a trained vascular access team using the ultrasound-guided micro-Seldinger technique and standardized protocols (SIP-Port and ISALT3). The primary outcome was the rate of severe adverse events (SAE) per 1000\u2009catheter-days (CD), defined as complications requiring device removal, hospitalization, or resulting in death. Secondary outcomes included transient adverse events (TAE).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 329 patients were included (172 chest ports, 157 PICC-ports). Baseline characteristics were broadly comparable between groups. SAE incidence was comparable between groups (0.47 vs 0.55 per 1000\u2009CD,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.672). Similarly, TAE rates showed no significant difference (1.05 vs 0.79 per 1000\u2009CD,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.331). However, PICC-ports had more frequent placement failures, while chest ports had significantly more catheter occlusions requiring urokinase (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.01).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In this retrospective cohort, PICC-ports demonstrated a safety profile comparable to chest ports, with fewer occlusions but more placement failures. These results support the routine clinical use of PICC-ports in eligible patients, though further randomized trials are needed to confirm long-term outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11297298261472624","type":"journal-article","created":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T13:43:46Z","timestamp":1786542226000},"page":"2787-2796","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative safety of PICC-ports and chest ports in oncology: A monocentric retrospective cohort study"],"prefix":"10.1177","volume":"27","author":[{"given":"Aubain","family":"Hillaireau","sequence":"first","affiliation":[{"name":"Pharmacy, H\u00f4pitaux du L\u00e9man, Thonon-les-Bains, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marion","family":"Warembourg","sequence":"additional","affiliation":[{"name":"Pharmacy, H\u00f4pitaux du L\u00e9man, Thonon-les-Bains, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Beaufr\u00e8re","sequence":"additional","affiliation":[{"name":"Vascular Access Unit, H\u00f4pitaux du L\u00e9man, Thonon les Bains, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathieu","family":"Leconte","sequence":"additional","affiliation":[{"name":"Vascular Access Unit, H\u00f4pitaux du L\u00e9man, Thonon les Bains, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tristan","family":"Roziere","sequence":"additional","affiliation":[{"name":"Independent Statistician, Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9313-4638","authenticated-orcid":false,"given":"Pascal","family":"Fangio","sequence":"additional","affiliation":[{"name":"Vascular Access Unit, H\u00f4pitaux du L\u00e9man, Thonon les Bains, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,8,12]]},"reference":[{"issue":"4","key":"e_1_3_2_2_2","first-page":"706","article-title":"Totally implanted venous and arterial access system to replace external catheters in cancer treatment","volume":"92","author":"Niederhuber JE","year":"1982","unstructured":"Niederhuber JE, Ensminger W, Gyves JW, et al. Totally implanted venous and arterial access system to replace external catheters in cancer treatment. Surgery 1982; 92(4): 706\u2013712.","journal-title":"Surgery"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00187683"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/11297298241300792"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/1129729818758999"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1473-3099(13)70266-4"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra011883"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bjc.6602082"},{"key":"e_1_3_2_9_2","first-page":"1","article-title":"Comparison between arm port and chest port for optimal vascular access port in patients with breast cancer: a systematic review and meta-analysis","volume":"2020","author":"Liu Y","year":"2020","unstructured":"Liu Y, Li L-L, Xu L, et al. Comparison between arm port and chest port for optimal vascular access port in patients with breast cancer: a systematic review and meta-analysis. Biomed Res Int 2020; 2020: 1\u20138.","journal-title":"Biomed Res Int"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/11297298231209521"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijscr.2020.02.028"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-022-01317-7"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jimed.2023.04.005"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.206.2.9457195"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/1129729819884482"},{"key":"e_1_3_2_16_2","article-title":"A multicenter retrospective study on 4480 implanted PICC-ports: a GAVeCeLT project","volume":"17","author":"Bertoglio S","year":"2022","unstructured":"Bertoglio S, Annetta MG, Brescia F, et al. A multicenter retrospective study on 4480 implanted PICC-ports: a GAVeCeLT project. J Vasc Access 2022; 17: Article 11297298211067683.","journal-title":"J Vasc Access"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12282-024-01608-z"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000609"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1177\/11297298221136330"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10549-005-1711-y"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bja.2019.01.038"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.2147\/CMAR.S205988"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/jan.13766"},{"key":"e_1_3_2_24_2","unstructured":"Pittiruti M Scoppettuolo G. GAVeCeLT Recommendations 2024 for the indication insertion and management of venous access devices https:\/\/gavecelt.it\/nuovo\/sites\/default\/files\/uploads\/raccomandazioni-gavecelt-2024.pdf (2024 accessed 20 January 2025)."},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.12968\/bjon.2022.31.8.S4"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejso.2011.06.016"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1002\/jhm.2207"},{"key":"e_1_3_2_28_2","unstructured":"Bertoglio S. Picc-port e rischio trombotico (PowerPoint presentation) presented at IV Convegno Picc-port; December 2024 https:\/\/gavecelt.it\/nuovo\/sites\/default\/files\/uploads\/Bertoglio%20-%20PICC-port%20e%20rischio%20trombotico.pdfhttps:\/\/gavecelt.it\/nuovo\/sites\/default\/files\/uploads\/Bertoglio%20-%20PICC-port%20e%20rischio%20tro\u2026"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/jth.14930"}],"container-title":["The Journal of Vascular Access"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11297298261472624","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11297298261472624","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11297298261472624","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T07:10:55Z","timestamp":1793862655000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11297298261472624"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,12]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1177\/11297298261472624"],"URL":"https:\/\/doi.org\/10.1177\/11297298261472624","relation":{},"ISSN":["1129-7298","1724-6032"],"issn-type":[{"value":"1129-7298","type":"print"},{"value":"1724-6032","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,12]]}}}