{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T10:35:11Z","timestamp":1792924511619,"version":"4.5.0"},"reference-count":44,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T00:00:00Z","timestamp":1787443200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"DOI":"10.13039\/501100012226","name":"Fundamental Research Funds for the Central Universities","doi-asserted-by":"publisher","award":["YG2025QNA03"],"award-info":[{"award-number":["YG2025QNA03"]}],"id":[{"id":"10.13039\/501100012226","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008233","name":"school of medicine, shanghai jiao tong university","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008233","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Vasc Access"],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Intensive serial blood sampling is critical for pharmacokinetics (PK) in Phase I trials but elevates pre-analytical hemolysis risks. While peripheral intravenous catheters (PIVCs) minimize needle trauma, evidence regarding device design remains inconsistent, potentially owing to unstandardized pre-analytical techniques across diverse clinical settings. This study introduced a rigorous evidence-based standard operating procedure (SOP) to minimize operational variability, aiming to clarify the respective, independent contributions of PIVC configurations versus temporal dynamics to specimen integrity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>\n                      In this single-center, prospective quasi-experimental comparative study, 246 healthy subjects (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u200982 per group) were allocated in a 1:1:1 ratio to 20\u2009G straight-type, Y-type, or single-port PIVCs for nine serial timepoints over 12\u2009h. All cohorts followed an evidence-based pre-analytical SOP featuring controlled tourniquet times, dead-space clearance, and low-pressure manual aspiration. Endpoints included specimen hemolysis, catheter occlusion, and re-cannulation rates. For the primary hemolysis endpoint, laboratory assessment was performed using coded specimens without catheter-group information provided to laboratory personnel.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Across 2194 PIVC specimens, the overall hemolysis rate was 2.01% (44\/2194), with no statistically detectable differences among straight-type (2.06%), Y-type (1.92%), and single-port (2.03%) cohorts (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.98). Firth\u2019s longitudinal regression detected no independent device effect (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.77); compared with straight-type, the odds of hemolysis were not statistically different for Y-type (OR\u2009=\u20090.82, 95% CI: 0.24\u20132.81) or single-port (OR\u2009=\u20090.65, 95% CI: 0.18\u20132.39) designs. Hemolysis incidence varied by sampling time, with the highest observed rate at the Pre-dose 1\u2009h sampling point (6.10%, 15\/246).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Under a rigorous evidence-based SOP, catheter configuration was not associated with statistically detectable differences in hemolysis or functional failure during intensive PK sampling. Quality control systems should prioritize procedural standardization over equipment selection. Further multicenter validation is needed before catheter- or time-specific sampling strategies are recommended.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/11297298261475798","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T05:21:31Z","timestamp":1787548891000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative evaluation of three peripheral intravenous catheter designs for intensive blood sampling in Phase I clinical trials: A prospective quasi-experimental comparative study"],"prefix":"10.1177","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-7490-1965","authenticated-orcid":false,"given":"Shulong","family":"Ding","sequence":"first","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-4501-8809","authenticated-orcid":false,"given":"Tianchun","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-2471-043X","authenticated-orcid":false,"given":"Shiyun","family":"Gu","sequence":"additional","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-4615-2862","authenticated-orcid":false,"given":"Xiaoqian","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-5281-7875","authenticated-orcid":false,"given":"Sijia","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-1477-0283","authenticated-orcid":false,"given":"Lu","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0670-3797","authenticated-orcid":false,"given":"Mengting","family":"Ji","sequence":"additional","affiliation":[{"name":"Department of Nursing, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"},{"name":"Clinical Research Unit, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,8,23]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejps.2024.106764"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-99-2302-1_15"},{"key":"e_1_3_3_4_2","article-title":"Phase I clinical trial of NH130 and the prediction of its pharmacokinetics using physiologically based pharmacokinetic modeling","volume":"15","author":"Zhang K","year":"2024","unstructured":"Zhang K, Zhao S, Du J, et al. Phase I clinical trial of NH130 and the prediction of its pharmacokinetics using physiologically based pharmacokinetic modeling. Front Pharmacol 2024; 15: 1474868.","journal-title":"Front Pharmacol"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.2147\/DDDT.S488414"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.3389\/fphar.2024.1342947"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.enfcli.2024.07.007"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12887-023-03855-z"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s13318-011-0077-2"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.psyneuen.2021.105220"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.15379\/ijmst.v10i2.3146"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000042952"},{"key":"e_1_3_3_13_2","unstructured":"Weeks HL Shotwell MS. Strategies to mitigate bias from time recording errors in pharmacokinetic studies https:\/\/scirate.com\/arxiv\/2310.15459 (2023 accessed 21 April 2026)."},{"key":"e_1_3_3_14_2","unstructured":"International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). ICH harmonised guideline: guideline for good clinical practice E6(R3). Step 4 version https:\/\/database.ich.org\/sites\/default\/files\/ICH_E6%28R3%29_Step4_FinalGuideline_2025_0106.pdf (2025 accessed 21 April 2026)."},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/11297298251385595"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000029268"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/jocn.14918"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.11613\/BM.2013.022"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1515\/tjb-2025-0027"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1208\/s12248-015-9783-z"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2013.01.021"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1114\/1.65"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1051\/ject\/2023015"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MAT.0000136512.36370.B5"},{"key":"e_1_3_3_25_2","first-page":"216","article-title":"Hemolysis by peripheral intravenous catheters: materials comparison","volume":"6","author":"Giavarina D","year":"2010","unstructured":"Giavarina D, Pasqualeb L, Mezzenaa G, et al. Hemolysis by peripheral intravenous catheters: materials comparison. Riv Ital Med Labor 2010; 6: 216\u2013221.","journal-title":"Riv Ital Med Labor"},{"issue":"12","key":"e_1_3_3_26_2","first-page":"2121","article-title":"Effect of different types of peripheral intravenous catheter connections on hemolysis rate of pediatric blood specimens","volume":"36","author":"Hou YM.","year":"2023","unstructured":"Hou YM. Effect of different types of peripheral intravenous catheter connections on hemolysis rate of pediatric blood specimens. Med Theory Pract 2023; 36(12): 2121\u20132122, 2144. (in Chinese)","journal-title":"Med Theory Pract"},{"issue":"7","key":"e_1_3_3_27_2","first-page":"63","article-title":"Comparison of straight-type and Y-type peripheral intravenous catheters for venous blood collection in infants","volume":"25","author":"Ma WW","year":"2018","unstructured":"Ma WW, Jiang JY. Comparison of straight-type and Y-type peripheral intravenous catheters for venous blood collection in infants. Chin J Rural Med Pharm 2018; 25(7): 63. (in Chinese)","journal-title":"Chin J Rural Med Pharm"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/NAN.0000000000000493"},{"key":"e_1_3_3_29_2","unstructured":"Children\u2019s Hospital Research Institute of Manitoba. 19 Repeated measures & clustered data. A primer in pediatric biostatistics. 2022. https:\/\/www.chrim.ca\/biostatistics-resources\/primer\/rmc.html (accessed 23 April 2026)."},{"issue":"7","key":"e_1_3_3_30_2","first-page":"632","article-title":"Evidence summary for blood sampling via short peripheral intravenous catheters","volume":"45","author":"Zhou TC","year":"2025","unstructured":"Zhou TC, Yu SJ, Chen L, et al. Evidence summary for blood sampling via short peripheral intravenous catheters. Tumor J 2025; 45(7): 632\u2013644. (in Chinese)","journal-title":"Tumor J"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/NAN.0000000000000532"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm8020144"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1080\/10408363.2019.1664391"},{"key":"e_1_3_3_34_2","unstructured":"National Health Commission of the People\u2019s Republic of China. Guidelines for venous blood specimen collection (WS\/T 661) https:\/\/www.nhc.gov.cn\/wjw\/s9492\/202004\/c09a4128e8194e40baad2498fd8a1f26.shtml (2020 accessed 24 April 2026)."},{"issue":"9","key":"e_1_3_3_35_2","first-page":"1334","article-title":"Expert consensus on clinical maintenance of intravenous catheters","volume":"54","author":"Intravenous Infusion Therapy Committee of Chinese Nursing Association","year":"2019","unstructured":"Intravenous Infusion Therapy Committee of Chinese Nursing Association, Sun H, Chen LF, et al. Expert consensus on clinical maintenance of intravenous catheters. Chin J Nurs 2019; 54(9): 1334\u20131340. (in Chinese)","journal-title":"Chin J Nurs"},{"key":"e_1_3_3_36_2","doi-asserted-by":"publisher","DOI":"10.12788\/jhm.2867"},{"key":"e_1_3_3_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/NAN.0000000000000326"},{"key":"e_1_3_3_38_2","article-title":"Reducing blood sample hemolysis in the emergency department using S-Monovette\u00ae in aspiration mode","volume":"35","author":"Omar E","year":"2023","unstructured":"Omar E, Allen JC, Jamil AKBM, et al. Reducing blood sample hemolysis in the emergency department using S-Monovette\u00ae in aspiration mode. Pract Lab Med 2023; 35: e00315.","journal-title":"Pract Lab Med"},{"key":"e_1_3_3_39_2","doi-asserted-by":"publisher","DOI":"10.1093\/jalm\/jfaf082"},{"key":"e_1_3_3_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jen.2023.06.001"},{"key":"e_1_3_3_41_2","doi-asserted-by":"publisher","DOI":"10.1093\/labmed\/lmz026"},{"key":"e_1_3_3_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0000000000000615"},{"key":"e_1_3_3_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2023.104673"},{"key":"e_1_3_3_44_2","doi-asserted-by":"publisher","DOI":"10.2105\/AJPH.94.3.361"},{"key":"e_1_3_3_45_2","doi-asserted-by":"publisher","DOI":"10.11124\/JBIES-23-00268"}],"container-title":["The Journal of Vascular Access"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11297298261475798","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/11297298261475798","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/11297298261475798","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T10:21:26Z","timestamp":1792923686000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/11297298261475798"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,23]]},"references-count":44,"alternative-id":["10.1177\/11297298261475798"],"URL":"https:\/\/doi.org\/10.1177\/11297298261475798","relation":{},"ISSN":["1129-7298","1724-6032"],"issn-type":[{"value":"1129-7298","type":"print"},{"value":"1724-6032","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,23]]},"article-number":"11297298261475798"}}