{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T23:47:46Z","timestamp":1777852066115,"version":"3.51.4"},"reference-count":30,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2014,2,4]],"date-time":"2014-02-04T00:00:00Z","timestamp":1391472000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Health Informatics J"],"published-print":{"date-parts":[[2015,9]]},"abstract":"<jats:p>\n                    Patient safety is a matter of major concern that involves every health professional. Nowadays, emerging technologies such as smart pumps can diminish medication errors as well as standardise and improve clinical practice with the subsequent benefits for patients. The aim of this paper was to describe the smart pump implementation process in a paediatric intensive care unit (PICU) and to present the most relevant infusion-related programming errors that were prevented. This was a comparative study between CareFusion Alaris Guardrails\n                    <jats:sup>\u00ae<\/jats:sup>\n                    and Hospira MedNet\n                    <jats:sup>\u00ae<\/jats:sup>\n                    systems, as well as a prospective and intervention study with analytical components carried out in the PICU of Gregorio Mara\u00f1\u00f3n General and Teaching Hospital. All intravenous infusions programmed with a pump in the eleven beds of the unit were analyzed. A drug library was developed and subsequently loaded into CareFusion and Hospira pumps that were used during a three month period each. The most suitable system for implementation was selected according to their differences in features and users\u2019 acceptance. Data stored in the pumps were analyzed to assess user compliance with the technology, health care setting and type of errors intercepted. The implementation process was carried out with CareFusion systems. Compliance with the technology was 92% and user acceptance was high. Vacation substitution and drug administration periods were significantly associated with a greater number of infusion-related programming errors. High risk drugs were involved in 48% of intercepted errors. Based on these results we can conclude that implementation of smart pumps proved effective in intercepting infusion-related programming errors from reaching patients. User awareness of the importance of programming infusions with the drug library is the key to succeed in the implementation process.\n                  <\/jats:p>","DOI":"10.1177\/1460458213518058","type":"journal-article","created":{"date-parts":[[2014,2,4]],"date-time":"2014-02-04T21:37:36Z","timestamp":1391549856000},"page":"209-222","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":11,"title":["Implementation of smart pump technology in a paediatric intensive care unit"],"prefix":"10.1177","volume":"21","author":[{"given":"Silvia","family":"Manrique-Rodr\u00edguez","sequence":"first","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"Amelia C","family":"S\u00e1nchez-Galindo","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"Ana","family":"de Lorenzo-Pinto","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"Leticia","family":"Gonz\u00e1lez-Vives","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"Jes\u00fas","family":"L\u00f3pez-Herce","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"\u00c1ngel","family":"Carrillo-\u00c1lvarez","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"Mar\u00eda","family":"Sanjurjo-S\u00e1ez","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]},{"given":"Cecilia M","family":"Fern\u00e1ndez-Llamazares","sequence":"additional","affiliation":[{"name":"Gregorio Mara\u00f1\u00f3n General and Teaching Hospital, Spain"}]}],"member":"179","published-online":{"date-parts":[[2014,2,4]]},"reference":[{"key":"bibr1-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1093\/ajhp\/52.4.390"},{"key":"bibr2-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1097\/00005110-200410000-00001"},{"key":"bibr3-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1097\/00006247-200010000-00021"},{"key":"bibr4-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1002\/jso.20126"},{"key":"bibr5-1460458213518058","first-page":"992","volume":"2003","author":"Rothschild JM","year":"2003","journal-title":"AMIA Annu Symp Proc"},{"key":"bibr6-1460458213518058","doi-asserted-by":"crossref","first-page":"119","DOI":"10.37573\/9781585282753.007","volume-title":"The pharmacy informatics primer","author":"Giannopoulos HT","year":"2008"},{"key":"bibr7-1460458213518058","volume-title":"Pediatric & neonatal dosage handbook","author":"Taketomo CK","year":"2010","edition":"18"},{"key":"bibr8-1460458213518058","unstructured":"Micromedex Healthcare\n                      \u00ae\n                      Series (base de datos en Internet). Greenwood Village, CO: Thomson Micromedex DRUGDEX\n                      \u00ae\n                      System, 1974\u20132012, http:\/\/www.micromedexsolutions.com\/home\/dispatch"},{"key":"bibr9-1460458213518058","unstructured":"Fichas t\u00e9cnicas del Centro de Informaci\u00f3n online de Medicamentos de la AEMPS \u2013 CIMA (base de datos en Internet). Madrid: Agencia Espa\u00f1ola de Medicamentos y Productos Sanitarios (AEMPS), https:\/\/sinaem4.agemed.es\/consaem\/fichasTecnicas.do?metodo=detalleForm (accessed 26 June 2012)."},{"key":"bibr10-1460458213518058","volume-title":"Teddy bear book: pediatric injectable drugs","author":"Phelps SJ","year":"2007","edition":"8"},{"key":"bibr11-1460458213518058","volume-title":"Handbook on injectable drugs","author":"Trissel LA","year":"2009","edition":"15"},{"key":"bibr12-1460458213518058","volume-title":"BNF for children 2010\u201311","author":"British Medical Association, Royal Pharmaceutical Society of Great Britain, Royal College of Paediatrics and Child Health and Neonatal and Paediatric Pharmacists Group","year":"2011"},{"key":"bibr13-1460458213518058","volume-title":"Dose error reduction systems for infusion pumps","author":"National Health System","year":"2008"},{"key":"bibr14-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijmedinf.2011.10.010"},{"key":"bibr15-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1016\/j.artmed.2011.12.001"},{"key":"bibr16-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1097\/NAN.0b013e3182425b34"},{"key":"bibr17-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1097\/01.mco.0000068969.34812.5d"},{"issue":"5","key":"bibr18-1460458213518058","first-page":"430","volume":"19","author":"Trbovich PL","year":"2010","journal-title":"Qual Saf Health Care"},{"issue":"8","key":"bibr19-1460458213518058","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.medcli.2010.01.016","volume":"137","author":"Manrique-Rodr\u00edguez S","year":"2011","journal-title":"Med Clin (Barc)"},{"key":"bibr20-1460458213518058","unstructured":"ISMP Espa\u00f1a. Listado de medicamentos de alto riesgo (monograf\u00eda en Internet), 2008, http:\/\/www.ismp-espana.org\/estaticos\/view\/39 (accessed 19 January 2012)."},{"key":"bibr21-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1310\/hpj4209-832"},{"key":"bibr22-1460458213518058","doi-asserted-by":"publisher","DOI":"10.2146\/ajhp090588"},{"key":"bibr23-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1590\/S0104-11692007000500020"},{"key":"bibr24-1460458213518058","doi-asserted-by":"publisher","DOI":"10.2146\/ajhp070633"},{"key":"bibr25-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijmedinf.2010.02.001"},{"key":"bibr26-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1097\/01.CCM.0000155912.73313.CD"},{"key":"bibr27-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2006.10.069"},{"key":"bibr28-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1093\/intqhc\/mzi015"},{"key":"bibr29-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1136\/qshc.2004.011957"},{"key":"bibr30-1460458213518058","doi-asserted-by":"publisher","DOI":"10.1007\/s11606-007-0414-y"}],"container-title":["Health Informatics Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1460458213518058","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1460458213518058","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1460458213518058","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:29:53Z","timestamp":1777501793000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/1460458213518058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2,4]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["10.1177\/1460458213518058"],"URL":"https:\/\/doi.org\/10.1177\/1460458213518058","relation":{},"ISSN":["1460-4582","1741-2811"],"issn-type":[{"value":"1460-4582","type":"print"},{"value":"1741-2811","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,2,4]]}}}