{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T11:35:09Z","timestamp":1787312109158,"version":"build-2736575974"},"reference-count":31,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T00:00:00Z","timestamp":1769126400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T00:00:00Z","timestamp":1769126400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Jiangsu Yuwell POCTech Biotechnology Co., Ltd., Jiangsu, China"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Diabetes Technology &amp; Therapeutics"],"published-print":{"date-parts":[[2026,8,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>This study evaluated the accuracy and safety of the Anytime 5Pro continuous glucose monitoring (CGM) system, a real-time, factory-calibrated device, over a 16-day period in adults with diabetes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Adult participants with type 1 or type 2 diabetes were recruited from three clinical sites in China. Each participant was equipped with four sensors (one on each upper arm and two on the abdomen) for a period of up to 16 days. To evaluate sensor performance, participants were randomly assigned to one of three 7-hour clinic sessions on days 1 or 2, days 7, 8 or 9, and day 16. During the sessions, the real-time glucose values measured by Anytime 5Pro CGM system were compared with venous blood glucose values measured by the EKF blood glucose detector. Primary endpoints for assessment were the mean absolute relative difference (MARD), the proportion of CGM values within \u00b120%\/\u00b120 mg\/dL of reference values, and the percentage of paired points within Zones A and B of the consensus error grids.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In the cohort of 72 participants (287 sensors), the CGM system exhibited an overall MARD of 8.58%, with 96.59% of values within the \u00b120%\/\u00b120 mg\/dL criteria. Comparative analysis revealed similar accuracy between arm (MARD: 8.58%; agreement: 97.03%) and abdomen (MARD: 8.58%; agreement: 96.16%) sensor placements. Throughout the 16-day wear period, the \u00b120%\/\u00b120 mg\/dL agreement rates remained above 95%, with MARDs ranging from 8.30%\u20138.88%. Consensus error grid analysis showed 99.99% of points in Zones A and B. No serious adverse events were reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The system demonstrated accurate glucose measurements across the 16-day wear period, irrespective of sensor placement site or glucose concentration.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15209156261416870","type":"journal-article","created":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T10:45:32Z","timestamp":1769165132000},"page":"848-857","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Performance of the Fifth Generation of a 16-Day Continuous Glucose Monitoring System in Adults with Diabetes"],"prefix":"10.1177","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-1724-6834","authenticated-orcid":false,"given":"Shichen","family":"Chang","sequence":"first","affiliation":[{"name":"Department of Endocrinology and Metabolism, Zhongshan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yibing","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Endocrinology, The Second Affiliated Hospital of Nanjing Medical University, Nanjing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongwei","family":"Ling","sequence":"additional","affiliation":[{"name":"Department of Endocrinology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guanqun","family":"Zhang","sequence":"additional","affiliation":[{"name":"Jiangsu Yuwell POCTech Biotechnology Co., Ltd., Jiangsu, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Jiangsu Yuwell POCTech Biotechnology Co., Ltd., Jiangsu, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoying","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Endocrinology and Metabolism, Zhongshan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Endocrinology and Metabolism, Zhongshan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,1,23]]},"reference":[{"key":"e_1_3_4_2_2","doi-asserted-by":"publisher","DOI":"10.2337\/dci18-0002"},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41591-024-02908-9"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/nrendo.2017.3"},{"key":"e_1_3_4_5_2","doi-asserted-by":"publisher","DOI":"10.2337\/dci23-0036"},{"key":"e_1_3_4_6_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc24-2222"},{"key":"e_1_3_4_7_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0134"},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc23-2194"},{"key":"e_1_3_4_9_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0805017"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2016.19975"},{"key":"e_1_3_4_11_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc11-1746"},{"key":"e_1_3_4_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.diabres.2008.09.051"},{"key":"e_1_3_4_13_2","doi-asserted-by":"publisher","DOI":"10.7326\/M16-2855"},{"key":"e_1_3_4_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.diabres.2024.111899"},{"key":"e_1_3_4_15_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc25-S007"},{"key":"e_1_3_4_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/19322968241267774"},{"key":"e_1_3_4_17_2","first-page":"193229682513293","article-title":"Accuracy of a 15-day factory-calibrated continuous glucose monitoring system with improved sensor design","author":"Alva S","year":"2025","unstructured":"Alva S, , Bhargava A, , Bode B, et al. Accuracy of a 15-day factory-calibrated continuous glucose monitoring system with improved sensor design. J Diabetes Sci Technol, 2025:19322968251329364.","journal-title":"J Diabetes Sci Technol"},{"key":"e_1_3_4_18_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2023.0468"},{"key":"e_1_3_4_19_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2025.0139"},{"key":"e_1_3_4_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/19322968211037991"},{"issue":"158","key":"e_1_3_4_21_2","first-page":"209","article-title":"Probable inference, the law of succession, and statistical inference","volume":"22","author":"Wilson EB","year":"1927","unstructured":"Wilson EB. Probable inference, the law of succession, and statistical inference. Jstor, 1927; 22(158):209\u2013212.","journal-title":"Jstor"},{"key":"e_1_3_4_22_2","unstructured":"U.S. Food and Drug Administration. Special controls for continuous glucose monitoring systems (iCGM). Silver Spring MD; 2018. Available from: https:\/\/www.fda.gov\/media\/119631\/download [Last accessed: December2 2025]."},{"key":"e_1_3_4_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/dom.14962"},{"key":"e_1_3_4_24_2","volume-title":"Performance Metrics for Continuous Interstitial Glucose Monitoring, 2nd ed. CLSI Guideline POCT05","author":"Clinical and Laboratory Standards Institute (CLSI)","year":"2020","unstructured":"Clinical and Laboratory Standards Institute (CLSI). Performance Metrics for Continuous Interstitial Glucose Monitoring, 2nd ed. CLSI Guideline POCT05. Clinical and Laboratory Standards Institute: 2020."},{"key":"e_1_3_4_25_2","unstructured":"U.S. Food and Drug Administration. Evaluation of automatic class III designation for Dexcom G6 continuous glucose monitoring system: Decision summary; 2018. Available from: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/reviews\/DEN170088.pdf [Last accessed: November29 2025]."},{"key":"e_1_3_4_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/19322968221091816"},{"key":"e_1_3_4_27_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2022.0011"},{"key":"e_1_3_4_28_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2017.0087"},{"key":"e_1_3_4_29_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296817706377"},{"key":"e_1_3_4_30_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2019.0014"},{"key":"e_1_3_4_31_2","unstructured":"Center for Medical Device Evaluation National Medical Products Administration. Guidelines for the technical review of registration for continuous glucose monitoring systems; 2023. Available from: https:\/\/www.cnpharm.com\/upload\/resources\/file\/2023\/07\/18\/141594.pdf [Last accessed: December26 2025]."},{"key":"e_1_3_4_32_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2023.0465"}],"container-title":["Diabetes Technology &amp; Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15209156261416870","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15209156261416870","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15209156261416870","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T11:10:26Z","timestamp":1787310626000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15209156261416870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,23]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8,1]]}},"alternative-id":["10.1177\/15209156261416870"],"URL":"https:\/\/doi.org\/10.1177\/15209156261416870","relation":{},"ISSN":["1520-9156","1557-8593"],"issn-type":[{"value":"1520-9156","type":"print"},{"value":"1557-8593","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,23]]}}}