{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T14:46:28Z","timestamp":1777819588315,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2002,2,1]],"date-time":"2002-02-01T00:00:00Z","timestamp":1012521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Endovasc Ther"],"published-print":{"date-parts":[[2002,2]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To present a 2-device technique for cerebral protection during carotid stenting of the internal carotid artery (ICA) in patients with high-grade lesions, contralateral occlusion, and\/or an aberrant or nonfunctioning circle of Willis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique:<\/jats:title>\n                    <jats:p>A reverse flow system (Parodi Anti-Embolism System [PAES]) is first placed with a 260-cm exchange wire in the common carotid artery 3 cm below the carotid bifurcation. Flow reversal is obtained by inflating the balloons in the external and common carotid arteries. Via an external connector, a guidewire and E-Trap filter are delivered to the distal ICA with active suction from a syringe on the PAES catheter. Once the filter is above the stenosis, the reversed flow is discontinued, and the procedure proceeds under cerebral protection with the filter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"conclusions\">\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The combination of 2 existing cerebral protection devices could, at least in theory, achieve what neither of them could independently. The \u201cseat belt and air bag\u201d approach may represent the ideal means of treating ICA stenoses in patients with a nonfunctioning circle of Willis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/152660280200900104","type":"journal-article","created":{"date-parts":[[2015,3,19]],"date-time":"2015-03-19T06:46:15Z","timestamp":1426747575000},"page":"20-24","source":"Crossref","is-referenced-by-count":50,"title":["\u201cSeat Belt and Air Bag\u201d Technique for Cerebral Protection during Carotid Stenting"],"prefix":"10.1177","volume":"9","author":[{"given":"Juan C.","family":"Parodi","sequence":"first","affiliation":[{"name":"Department of Vascular Surgery, Instituto Cardiovascular de Buenos Aires"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudio","family":"Sch\u00f6nholz","sequence":"additional","affiliation":[{"name":"La Sagrada Familia Medical Center, Buenos Aires, Argentina"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L. Mariano","family":"Ferreira","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery, Instituto Cardiovascular de Buenos Aires"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Esteban","family":"Mendaro","sequence":"additional","affiliation":[{"name":"La Sagrada Familia Medical Center, Buenos Aires, Argentina"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"Ohki","sequence":"additional","affiliation":[{"name":"Montefiore Medical Center, New York, New York, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2002,2]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s100169900211"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(98)70182-X"},{"key":"e_1_2_1_4_2","first-page":"150","article-title":"Angioplasty and stenting of the extracranial carotid arteries","volume":"27","author":"Henry M","year":"2000","unstructured":"Henry M, Amor M, Klonaris C, . Angioplasty and stenting of the extracranial carotid arteries. Tex Heart Inst J. 2000; 27: 150\u2013158.","journal-title":"Tex Heart Inst J."},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(00)00618-5"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(98)70321-0"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2000.102730"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/096721099900700108"},{"key":"e_1_2_1_9_2","first-page":"113","article-title":"Innominate artery angioplasty","volume":"5","author":"Vitek JJ","year":"1984","unstructured":"Vitek JJ, Raymon BC, Oh SJ. Innominate artery angioplasty. AJNR Am J Neuroradiol. 1984; 5: 113\u2013114.","journal-title":"AJNR Am J Neuroradiol."},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/152660289600300109"},{"key":"e_1_2_1_11_2","first-page":"869","article-title":"New triple coaxial catheter system for carotid angioplasty with cerebral protection","volume":"11","author":"Th\u00e9ron J","year":"1990","unstructured":"Th\u00e9ron J, Courtheoux P, Alachkar F, . New triple coaxial catheter system for carotid angioplasty with cerebral protection. AJNR Am J Neuroradiol. 1990; 11: 869\u2013874.","journal-title":"AJNR Am J Neuroradiol."},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/152660289900600405"},{"key":"e_1_2_1_13_2","first-page":"495","article-title":"Percutaneous angioplasty of atherosclerotic and postsurgical stenosis of carotid arteries","volume":"8","author":"Theron J","year":"1987","unstructured":"Theron J, Raymond J, Casasco A, . Percutaneous angioplasty of atherosclerotic and postsurgical stenosis of carotid arteries. Am J Neuroradiol. 1987; 8: 495\u2013500.","journal-title":"Am J Neuroradiol."},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(99)70041-8"},{"key":"e_1_2_1_15_2","first-page":"144","article-title":"Carotid stenting with and without protection devices: Should protection be used in all patients?","volume":"13","author":"Ohki T","year":"2000","unstructured":"Ohki T, Veith FJ. Carotid stenting with and without protection devices: Should protection be used in all patients? Semin Vasc Surg. 2000; 13: 144\u2013152.","journal-title":"Semin Vasc Surg."},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2000.109209"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/152660280200900102"},{"key":"e_1_2_1_18_2","first-page":"33","article-title":"International multi-center Parodi Anti-Emboli System Study: Preliminary results [abstract]","volume":"86","author":"Parodi JC","year":"2000","unstructured":"Parodi JC, Bates MC, Sch\u00f6nholz C, . International multi-center Parodi Anti-Emboli System Study: Preliminary results [abstract]. Am J Cardiol. 2000; 86(Suppl 8A): 33.","journal-title":"Am J Cardiol."},{"key":"e_1_2_1_19_2","first-page":"34","article-title":"E-Trap: A new device to prevent distal embolization during carotid percutaneous transluminal angioplasty and stenting [abstract]","volume":"86","author":"Sch\u00f6nholz C","year":"2000","unstructured":"Sch\u00f6nholz C, Mendaro E, Sierre S. E-Trap: A new device to prevent distal embolization during carotid percutaneous transluminal angioplasty and stenting [abstract]. Am J Cardiol. 2000; 86(Suppl 8A): 34.","journal-title":"Am J Cardiol."}],"container-title":["Journal of Endovascular Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/152660280200900104","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/152660280200900104","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T21:28:28Z","timestamp":1777498108000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/152660280200900104"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,2]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2002,2]]}},"alternative-id":["10.1177\/152660280200900104"],"URL":"https:\/\/doi.org\/10.1177\/152660280200900104","relation":{},"ISSN":["1526-6028","1545-1550"],"issn-type":[{"value":"1526-6028","type":"print"},{"value":"1545-1550","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,2]]}}}