{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,3]],"date-time":"2026-05-03T14:59:16Z","timestamp":1777820356188,"version":"3.51.4"},"reference-count":8,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T00:00:00Z","timestamp":1724716800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Endovasc Ther"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This technical note presents a case of a patient with a failed Nellix device (Endologix, Irvine, Calif) who was not deemed fit for open conversion. Our planned approach for repair involved an endovascular procedure utilizing a custom-made branched device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technique:<\/jats:title>\n                    <jats:p>An endovascular repair was performed via a custom-made four outer branched device in conjunction with a custom-made bifurcated graft featuring inverted limbs (Cook Inc., Bloomington, Ind). All branches were connected to the target vessel with Gore Viabahn VBX balloon-expandable covered stents (Gore &amp; Associates Inc.).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Endovascular conversion with branched endovascular repair in a patient not deemed fit for open surgery was successfully performed, thereby reducing the risk of a high morbid and mortal procedure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Impact<\/jats:title>\n                    <jats:p>Novel useful treatment solution of failed EVAR with Nellix device.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15266028241276961","type":"journal-article","created":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T03:32:07Z","timestamp":1724729527000},"page":"605-608","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":1,"title":["Endovascular Conversion of a Failed Nellix AAA-Repair by a Custom-Made Branched Device"],"prefix":"10.1177","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-5724-4826","authenticated-orcid":false,"given":"Baban","family":"Assaf","sequence":"first","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, St. Franziskus-Hospital Muenster, Munster, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin J.","family":"Austermann","sequence":"additional","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, St. Franziskus-Hospital Muenster, Munster, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9725-6484","authenticated-orcid":false,"given":"Marco V.","family":"Usai","sequence":"additional","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, St. Franziskus-Hospital Muenster, Munster, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2024,8,27]]},"reference":[{"key":"e_1_3_3_2_2","unstructured":"Endologix Inc. Nellix polymer sheet (MM1250 Rev 01). https:\/\/endologix.com\/wp-content\/uploads\/2016\/09\/MM1250Rev01-Nellix-Polymer-Sheet-Disposable-_04-20.pdf."},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2016.02.053"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2020.11.004"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2022.12.031"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2018.09.020"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2019.04.482"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2019.01.044"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2023.01.205"}],"container-title":["Journal of Endovascular Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15266028241276961","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15266028241276961","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15266028241276961","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T21:30:57Z","timestamp":1777498257000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15266028241276961"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,27]]},"references-count":8,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1177\/15266028241276961"],"URL":"https:\/\/doi.org\/10.1177\/15266028241276961","relation":{},"ISSN":["1526-6028","1545-1550"],"issn-type":[{"value":"1526-6028","type":"print"},{"value":"1545-1550","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,27]]}}}