{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T11:03:06Z","timestamp":1789556586357,"version":"build-2803163510"},"reference-count":21,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T00:00:00Z","timestamp":1756166400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["J Endovasc Ther"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:p>\n                    <jats:bold>Introduction:<\/jats:bold>\n                    The endovascular surgical approach provides a minimally invasive treatment of abdominal aortic aneurysms with less perioperative morbidity. This technique depends heavily on imaging to diagnose, plan surgical treatment, conduct the surgical procedure, and follow-up with patients. Image fusion technique was proposed to decrease radiation and injected contrast exposure; however, the accuracy of image fusion still needs to be improved. One of the major causes of this inaccuracy is the displacement of visceral arteries during respiration.\n                    <jats:bold>Objective:<\/jats:bold>\n                    To analyze the physiological respiration-induced movements of the abdominal aortic side branches.\n                    <jats:bold>Materials and Methods:<\/jats:bold>\n                    Thirty healthy volunteers were studied using noncontrast-enhanced MRI. Images were acquired in expiratory and inspiratory forced breath-holds. The displacements were studied by calculating 3-dimensional expiration-inspiration vectors of measured points; diaphragmatic domes, origins of the celiac trunk (CTA), superior mesenteric artery (SMA), right renal artery (RRA), and left renal artery (LRA) as well as the kidneys hila.\n                    <jats:bold>Results:<\/jats:bold>\n                    For all measured points, the superior-inferior displacements were the most important component of movement vectors, and they were statistically significant. The right hemidiaphragm moved by 33.35\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, the left hemidiaphragm by 32.4\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, the right kidney moved by 19.56\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, the left kidney moved by 23.64\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, the origin of CTA moved by 3.41\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, the origin of SMA moved by 3.54\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, the origin of RRA moved by 3.03\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001, and the origin of moved LRA by 3.17\u2009mm\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009&lt;\u2009.001.\n                    <jats:bold>Conclusion:<\/jats:bold>\n                    We found significant displacements of abdominal aortic branches from forced expiratory to forced inspiratory position. There is a positive correlation between diaphragmatic movement and all visceral arteries orifices displacements; however, this correlation is not high enough to be relayed upon for image fusion correction. Considering only the level of diaphragm to predict the level of abdominal branches origins is insufficient to correct image fusion inaccuracy. We suggest using a dynamic preoperative study as fusion model. Finally, this analysis protocol should be reapplied to a sample of patients with abdominal aneurysm to evaluate respiration-induced movements of the abdominal aortic side branches in pathological condition.\n                  <\/jats:p>\n                  <jats:sec>\n                    <jats:title>Clinical Impact<\/jats:title>\n                    <jats:p>Although it is known that visceral arteries move with respiration, the specific patterns and influencing factors remain unclear. No large-scale studies have quantified this motion under physiological conditions, and current understanding relies mainly on anatomical assumptions rather than detailed evidence.<\/jats:p>\n                    <jats:p>Understanding and predicting this movement has clear clinical implications. Accurate characterization of respiratory-induced arterial motion could improve image registration and fusion techniques, enhance navigation during endovascular or surgical interventions, and reduce errors related to motion artifacts. Ultimately, building predictive models of arterial dynamics may lead to safer procedures, more precise device deployment, and better patient outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15266028251363487","type":"journal-article","created":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T07:58:34Z","timestamp":1756195114000},"page":"2592-2599","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Respiration-Induced Displacements of Abdominal Aortic Branches\u2014An MRI Study"],"prefix":"10.1177","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5694-6968","authenticated-orcid":false,"given":"Hossam I.","family":"Shaabi","sequence":"first","affiliation":[{"name":"Vascular and Endoluminal Surgery Department, CHRU de Nancy, France"},{"name":"Department of Surgery, Faculty of Medicine, Jazan University, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicla","family":"Settembre","sequence":"additional","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, Nancy University Hospital, University of Lorraine, Nancy, France"},{"name":"INSERM UMR 1116 DCAC, University of Lorraine, Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacques","family":"Felblinger","sequence":"additional","affiliation":[{"name":"IADI U1254, Inserm, Universit\u00e9 de Lorraine, Nancy, France"},{"name":"CIC 1433, Innovation Technologique, Inserm, Universit\u00e9 de Lorraine, CHRU-Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-2475-7663","authenticated-orcid":false,"given":"Maya","family":"Delbany","sequence":"additional","affiliation":[{"name":"IADI U1254, Inserm, Universit\u00e9 de Lorraine, Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damien","family":"Mandry","sequence":"additional","affiliation":[{"name":"Department of Radiology, Nancy University Hospital, University of Lorraine, Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serguei","family":"Malikov","sequence":"additional","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, Nancy University Hospital, University of Lorraine, Nancy, France"},{"name":"INSERM UMR 1116 DCAC, University of Lorraine, Nancy, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,8,26]]},"reference":[{"issue":"6","key":"e_1_3_3_2_2","first-page":"84","article-title":"A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm","author":"Volodos N","year":"1988","unstructured":"Volodos N, Karpovich I, Shekhanin V, Troian V, Iakovenko F. A case of distant transfemoral endoprosthesis of the thoracic artery using a self-fixing synthetic prosthesis in traumatic aneurysm. Grudn Khir. 1988;(6):84\u201386.","journal-title":"Grudn Khir"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2009.07.001"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2018.09.020"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-012-0446-5"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2013.12.022"},{"issue":"6","key":"e_1_3_3_7_2","first-page":"897","article-title":"Pros and cons of 3D image fusion in endovascular aortic repair: A systematic review and meta-analysis","volume":"24","author":"Goudeketting SR","year":"2017","unstructured":"Goudeketting SR, Heinen SG, \u00dcnl\u00fc \u00c7, et al Pros and cons of 3D image fusion in endovascular aortic repair: A systematic review and meta-analysis. J Endovasc Ther. 2017;24(6):897\u2013911.","journal-title":"J Endovasc Ther"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2020.10.016"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2022.08.002"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2022.11.041"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2018.03.032"},{"key":"e_1_3_3_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/1526602815605325"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2013.04.011"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12194-008-0025-2"},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.1583\/05-1530.1"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24101"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2013.04.006"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.1583\/09-2987MR.1"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2586(200012)12:6<924::AID-JMRI16>3.0.CO;2-0"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1258\/cvd.2012.012024"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/ca.20748"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.12669\/pjms.334.13063"}],"container-title":["Journal of Endovascular Therapy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15266028251363487","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15266028251363487","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15266028251363487","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T10:14:57Z","timestamp":1789553697000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15266028251363487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,26]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["10.1177\/15266028251363487"],"URL":"https:\/\/doi.org\/10.1177\/15266028251363487","relation":{},"ISSN":["1526-6028","1545-1550"],"issn-type":[{"value":"1526-6028","type":"print"},{"value":"1545-1550","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,26]]}}}