{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T00:32:55Z","timestamp":1777941175983,"version":"3.51.4"},"reference-count":32,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Technol Cancer Res Treat"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>CyberKnife treatment for central lung tumors and mediastinal tumors can be difficult to perform with marker less.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>We aimed to evaluate a novel tracheobronchial-based method (ie, tracheobronchial tracking) for the purpose of minimally invasive CyberKnife treatment for central lung and mediastinal tumors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Five verification plans were created using an in-house phantom. Each plan included five irradiation sessions. The reference plan irradiated and tracked the simulated tumor (using the target tracking volume, TTV). Trachea plans tracked the simulated tracheo-bronchus and irradiated the simulated tumor and included two types of subplans: correlated plans in which the displacement of the simulated tracheobronchial and the simulated tumor were correlated, and non-correlated plans in which these factors were not correlated. Moreover, 15\u2005mm and 25\u2005mm TTVs were evaluated for each plan. The sin waveform and the patient's respiratory waveform were prepared as the respiratory model. Evaluations were performed by calculating the dose difference between the radiophotoluminescent glass dosimeter (RPLD)-generated mean dose values (generated by the treatment planning system, TPS) and the actual absorbed RPLD dose. Statistical analyses were performed to evaluate findings for each plan. Correlation and prediction errors were calculated for each axis of each plan using log files to evaluate tracking accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Dose differences were statistically significant only in comparisons with the non-correlated plan. When evaluated using the sin waveform, the mean values for correlation and prediction errors in each axis and for all plans were less than 0.6\u2005mm and 0.1\u2005mm, respectively. In the same manner, they were less than 1.1\u2005mm and 0.2\u2005mm when evaluated using the patient's respiratory waveform.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Our newly-developed tracheobronchial tracking method would be useful in facilitating minimally invasive CyberKnife treatment in certain cases of central lung and mediastinal tumors.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15330338241232557","type":"journal-article","created":{"date-parts":[[2024,2,20]],"date-time":"2024-02-20T18:33:26Z","timestamp":1708454006000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of a New Method for CyberKnife Treatment for Central Lung and Mediastinal Tumors by Tracheobronchial Tracking"],"prefix":"10.1177","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0414-5218","authenticated-orcid":false,"given":"Toshihiro","family":"Suzuki","sequence":"first","affiliation":[{"name":"CyberKnife Center, Kasugai General Rehabilitation Hospital, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8636-4045","authenticated-orcid":false,"given":"Masahide","family":"Saito","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Takahashi","sequence":"additional","affiliation":[{"name":"CyberKnife Center, Kasugai General Rehabilitation Hospital, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidekazu","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Makino","sequence":"additional","affiliation":[{"name":"Department of Mechatronics, Faculty of Engineering, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Ueda","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Mochizuki","sequence":"additional","affiliation":[{"name":"CyberKnife Center, Kasugai General Rehabilitation Hospital, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zennosuke","family":"Mochizuki","sequence":"additional","affiliation":[{"name":"CyberKnife Center, Kasugai General Rehabilitation Hospital, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hikaru","family":"Nemoto","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Sano","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3512-1166","authenticated-orcid":false,"given":"Hiroshi","family":"Onishi","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Yamanashi, Yamanashi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2024,2,20]]},"reference":[{"key":"bibr1-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-42"},{"key":"bibr2-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2015.03.004"},{"key":"bibr3-15330338241232557","author":"Onishi H","journal-title":"International Journal of Radiation Oncology* Biology* Physics"},{"key":"bibr4-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2005.01.002"},{"issue":"1","key":"bibr5-15330338241232557","volume":"3","author":"Teh BS","year":"2007","journal-title":"Biomed Imaging Intervention J."},{"key":"bibr6-15330338241232557","author":"Goldsmith C","journal-title":"Cureus"},{"key":"bibr7-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.4955437"},{"issue":"1","key":"bibr8-15330338241232557","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-016-0028-x","volume":"7","author":"Yang Z-Y","year":"2017","journal-title":"Sci Rep."},{"key":"bibr9-15330338241232557","doi-asserted-by":"publisher","DOI":"10.3816\/CLC.2007.n.002"},{"key":"bibr10-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-7-102"},{"key":"bibr11-15330338241232557","doi-asserted-by":"publisher","DOI":"10.3857\/roj.2015.33.2.89"},{"key":"bibr12-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.3596527"},{"key":"bibr13-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.1758351"},{"key":"bibr14-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1002\/jmrs.445"},{"key":"bibr15-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.1861155"},{"key":"bibr16-15330338241232557","author":"Saito M","year":"2023","journal-title":"J Appl Clin Med Phys."},{"key":"bibr17-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(02)02803-1"},{"key":"bibr18-15330338241232557","unstructured":"International Organization for Standardization (ISO). ISO 22127 Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV x-ray radiotherapy. https:\/\/www.iso.org\/standard\/72639.html;2019."},{"key":"bibr19-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2021.06.010"},{"key":"bibr20-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.12.041"},{"key":"bibr21-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13476"},{"key":"bibr22-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2017.10.014"},{"key":"bibr23-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2018.11.005"},{"key":"bibr24-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2011.12.023"},{"key":"bibr25-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1080\/02841860600902205"},{"key":"bibr26-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.2349696"},{"key":"bibr27-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1080\/16878507.2019.1594092"},{"key":"bibr28-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2022.106753"},{"key":"bibr29-15330338241232557","unstructured":"ICRU (International Commission on Radiation Units and Measurements). Determination of absorbed dose in a patient irradiated by beams of X or gamma rays in radiotherapy procedures. 4th ed. Report 24. ICRU Publications; 1976: 45-50."},{"key":"bibr30-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.4951731"},{"key":"bibr31-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1118\/1.4927557"},{"key":"bibr32-15330338241232557","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13028"}],"container-title":["Technology in Cancer Research &amp; Treatment"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15330338241232557","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15330338241232557","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15330338241232557","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T06:14:18Z","timestamp":1777702458000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15330338241232557"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":32,"alternative-id":["10.1177\/15330338241232557"],"URL":"https:\/\/doi.org\/10.1177\/15330338241232557","relation":{},"ISSN":["1533-0346","1533-0338"],"issn-type":[{"value":"1533-0346","type":"print"},{"value":"1533-0338","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1]]},"article-number":"15330338241232557"}}