{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T11:55:54Z","timestamp":1790942154666,"version":"4.1.0"},"reference-count":27,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:00:00Z","timestamp":1790640000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Epilepsy Curr"],"abstract":"<jats:p>Identifying and localizing the epileptogenic zone (EZ) is the cornerstone of successful epilepsy surgery, as it directly determines surgical efficacy and patient outcomes. Stereoelectroencephalography (SEEG) has emerged as a transformative tool for pinpointing the EZ, offering precise 3-dimensional recordings of seizure activity in individual patients. SEEG does not begin with electrode implantation, but with the formulation of a precise hypothesis regarding the epileptogenic networks involved. This hypothesis is based on data gathered during Phase I investigations, particularly the electroclinical correlations of seizure obtained from video-EEG monitoring. SEEG can be appropriately performed only when a prior estimation of EZ and propagation networks is available. The guiding principle of SEEG is therefore not exhaustive anatomical coverage, but rather the validation of a predefined hypothesis. Consequently, certain brain regions are deliberately not explored, there is always missing electrodes. However, in some cases, we encounter true \u201cmissing\u201d electrodes, unanticipated gaps in electrode coverage, that can profoundly impact the diagnostic process. These missing electrodes may create critical gaps in the spatial sampling of epileptic networks, leading to incomplete localization of the EZ. This limitation can hinder the identification of seizure onset zone, propagation pathways, and network interactions, ultimately restricting surgical options and compromising patient outcomes. Current clinical practice highlights a significant knowledge gap in how to anticipate such issues during SEEG planning and how to optimally interpret data when electrode coverage is suboptimal. Key questions remain: How can electrode placement errors be identified early? And how can emerging technologies help compensate for these gaps? In this article, we aim to illustrate and discuss these critical issues.<\/jats:p>","DOI":"10.1177\/15357597261460901","type":"journal-article","created":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T14:38:05Z","timestamp":1790692685000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["How to Recognize and Manage Missing Key Electrodes in Defining the Epileptogenic Zone"],"prefix":"10.1177","author":[{"given":"Hussam","family":"Shaker","sequence":"first","affiliation":[{"name":"Trinity Health Grand Rapids, Hauenstein Neurosciences Center, Grand Rapids, MI, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Medina Villalon","sequence":"additional","affiliation":[{"name":"AP-HM, H\u00f4pital de la Timone, Service de Neurophysiologie Clinique, Marseille, France"},{"name":"Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9936-7034","authenticated-orcid":false,"given":"Jorge","family":"Gonzalez-Martinez","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8632-3454","authenticated-orcid":false,"given":"Agnes","family":"Trebuchon","sequence":"additional","affiliation":[{"name":"AP-HM, H\u00f4pital de la Timone, Service de Neurophysiologie Clinique, Marseille, France"},{"name":"Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,9,29]]},"reference":[{"key":"e_1_3_2_2_2","volume-title":"La st\u00e9r\u00e9o-\u00e9lectro-enc\u00e9phalographie dans l'\u00e9pilepsie. Informations neuro-physio-pathologiques apport\u00e9es par l'investigation fonctionnelle st\u00e9r\u00e9otaxique","author":"Bancaud J","year":"1965","unstructured":"Bancaud J, Talairach J, Bonis A, Szikla G, Morel P, BordasFerrer M. La st\u00e9r\u00e9o-\u00e9lectro-enc\u00e9phalographie dans l'\u00e9pilepsie. Informations neuro-physio-pathologiques apport\u00e9es par l'investigation fonctionnelle st\u00e9r\u00e9otaxique. Masson; 1965."},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neucli.2017.11.005"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-443-10877-8.00003-6"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/epi.14604"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/awn111"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/awx306"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2020.05.029"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2016.2556425"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.25124"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.26548"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-024-49470-z"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2023.119905"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.eplepsyres.2016.10.013"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2014.04.058"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2019.12.408"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2022.08.013"},{"key":"e_1_3_2_18_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3389\/fneur.2022.782880","article-title":"SEEG in 3D: interictal source localization from intracerebral recordings","volume":"13","author":"Satzer D","year":"2022","unstructured":"Satzer D, Esengul YT, Warnke PC, et al. SEEG in 3D: interictal source localization from intracerebral recordings. Front Neurol. 2022;13(February):1\u201011.","journal-title":"Front Neurol"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2017.03.030"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10548-023-00994-5"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-54359-4"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2016.04.049"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/awx004"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(23)00008-X"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/epi.17310"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.abp8982"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-443-10877-8.00008-5"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.26883"}],"container-title":["Epilepsy Currents"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15357597261460901","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15357597261460901","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15357597261460901","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T11:16:43Z","timestamp":1790939803000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15357597261460901"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,29]]},"references-count":27,"alternative-id":["10.1177\/15357597261460901"],"URL":"https:\/\/doi.org\/10.1177\/15357597261460901","relation":{},"ISSN":["1535-7597","1535-7511"],"issn-type":[{"value":"1535-7597","type":"print"},{"value":"1535-7511","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,29]]},"article-number":"15357597261460901"}}