{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T15:16:40Z","timestamp":1785770200999,"version":"3.56.0"},"reference-count":29,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T00:00:00Z","timestamp":1662681600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Vasc Endovascular Surg"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:p>\n                    <jats:bold>Background and aims<\/jats:bold>\n                    : This study describes and demonstrates the applicability of a novel in silico method for modeling progressive carotid artery stenosis using the oscillatory shear index (OSI) as the basis of stenosis.\n                    <jats:bold>Methods<\/jats:bold>\n                    : Three-dimensional reconstructions of 11 carotid arteries were generated using patient-derived magnetic resonance angiography and duplex ultrasound data. Computational fluid dynamic simulations were sequentially generated following computational stenosis assessment, and corresponding changes in OSI were observed and used as measure of morphological stabilization.\n                    <jats:bold>Results<\/jats:bold>\n                    : 6 carotid models showed progressive stenosis with statistically significant increases in regions of high OSI (OSI &gt;.2,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; .05) with eventual carotid occlusion in 1 of the cases. Three models remained free or nearly free of increased OSI, whereas 1 model showed an overall decrease in high OSI regions (P &lt; .05) and another trended in that direction but did not achieve statistical significance (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    = .145).\n                    <jats:bold>Conclusions<\/jats:bold>\n                    : To our knowledge, this is the first computational model describing progressive stenosis in any peripheral artery including the carotid. Taken together, this study provides a novel framework for computational hemodynamic investigations on progressive atherosclerosis in the carotid artery.\n                  <\/jats:p>","DOI":"10.1177\/15385744221116837","type":"journal-article","created":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T14:41:12Z","timestamp":1662734472000},"page":"26-34","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":6,"title":["An Oscillatory Shear Index-Based Model to Describe Progressive Carotid Artery Stenosis"],"prefix":"10.1177","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2295-705X","authenticated-orcid":false,"given":"Peter","family":"Patalano","sequence":"first","affiliation":[{"name":"New York University School of Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,9,9]]},"reference":[{"key":"e_1_3_5_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM200006083422302"},{"key":"e_1_3_5_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0912321"},{"key":"e_1_3_5_4_2","doi-asserted-by":"publisher","DOI":"10.3171\/2009.10.JNS09759"},{"key":"e_1_3_5_5_2","doi-asserted-by":"publisher","DOI":"10.1586\/erc.10.28"},{"key":"e_1_3_5_6_2","doi-asserted-by":"publisher","DOI":"10.1160\/TH15-07-0597"},{"key":"e_1_3_5_7_2","doi-asserted-by":"publisher","DOI":"10.14348\/molcells.2014.0078"},{"key":"e_1_3_5_8_2","doi-asserted-by":"publisher","DOI":"10.1080\/07853890802186921"},{"key":"e_1_3_5_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.carpath.2012.06.006"},{"key":"e_1_3_5_10_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra043430"},{"key":"e_1_3_5_11_2","volume-title":"Computational Hemodynamics - Theory, Modeling and Applications.Biological and Medical Physics, Biomedical Engineering. SpringerNetherlands: Imprint","author":"Tu J","year":"2015","unstructured":"Tu J, Inthavong K, Kelvin Kian Loong Wong. Computational Hemodynamics - Theory, Modeling and Applications.Biological and Medical Physics, Biomedical Engineering. SpringerNetherlands: Imprint. 1st ed. Dordrecht: Springer; 2015.","edition":"1"},{"key":"e_1_3_5_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11748-017-0834-5"},{"key":"e_1_3_5_13_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41569-019-0239-5"},{"key":"e_1_3_5_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/cvr\/cvt044"},{"key":"e_1_3_5_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-009-9697-y"},{"key":"e_1_3_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2015.04.421"},{"key":"e_1_3_5_17_2","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2019.00111"},{"key":"e_1_3_5_18_2","doi-asserted-by":"publisher","DOI":"10.1074\/jbc.M305150200"},{"key":"e_1_3_5_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.0000145728.22878.45"},{"issue":"10","key":"e_1_3_5_20_2","first-page":"1018","article-title":"Hemodynamics and atherosclerosis. insights and perspectives gained from studies of human arteries","volume":"112","author":"Glagov S","year":"1988","unstructured":"Glagov S, Zarins C, Giddens DP, Ku DN. Hemodynamics and atherosclerosis. insights and perspectives gained from studies of human arteries. Arch Pathol Lab Med. 1988;112(10):1018-1031.","journal-title":"Arch Pathol Lab Med"},{"key":"e_1_3_5_21_2","doi-asserted-by":"publisher","unstructured":"Storch AS Rocha HNM Garcia VP et al. Oscillatory shear stress induces hemostatic imbalance in healthy men.Thrombosis Research 119\u2013125 2018. doi: 10.1016\/j.thromres.2018.08.019.","DOI":"10.1016\/j.thromres.2018.08.019"},{"key":"e_1_3_5_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/ncpcardio1397"},{"key":"e_1_3_5_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/cvr\/cvz212"},{"key":"e_1_3_5_24_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-80681-8"},{"key":"e_1_3_5_25_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.atv.5.3.293"},{"key":"e_1_3_5_26_2","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/31\/3\/002"},{"key":"e_1_3_5_27_2","doi-asserted-by":"publisher","DOI":"10.1098\/rsif.2013.0193"},{"key":"e_1_3_5_28_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0166569"},{"key":"e_1_3_5_29_2","doi-asserted-by":"publisher","DOI":"10.1115\/IMECE2017-71432"},{"key":"e_1_3_5_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2007.02.059"}],"container-title":["Vascular and Endovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15385744221116837","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15385744221116837","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15385744221116837","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T06:33:11Z","timestamp":1777703591000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15385744221116837"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,9]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["10.1177\/15385744221116837"],"URL":"https:\/\/doi.org\/10.1177\/15385744221116837","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2022.02.04.479106","asserted-by":"object"}]},"ISSN":["1538-5744","1938-9116"],"issn-type":[{"value":"1538-5744","type":"print"},{"value":"1938-9116","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,9]]}}}