{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T04:26:39Z","timestamp":1770006399677,"version":"3.49.0"},"reference-count":15,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T00:00:00Z","timestamp":1590969600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Distributed Sensor Networks"],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:p> With the wide application of microgrid system, fluctuation and randomness are the characteristics of distributed generation output. The traditional energy management system can\u2019t meet the requirements to ensure the security and stability of the grid. The microgrid energy management is of great significance to the stable operation of power grid. In order to obtain higher economic benefits and pay less environmental costs, reasonable scheduling of various distributed power sources is able to achieve this goal. In this article, microgrid energy management including distributed generation is studied. The objective function includes the economic objective and the environmental objective. The model of energy management is considered as a multi-objectives and multi-parametric optimization problem. The multi-parameter dynamic programming is used to optimize the energy management of microgrid. Finally, the efficiency of the proposed method is examined by the simulation studies. <\/jats:p>","DOI":"10.1177\/1550147720937141","type":"journal-article","created":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T08:39:21Z","timestamp":1593247161000},"page":"155014772093714","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":16,"title":["Optimal energy management of microgrid based on multi-parameter dynamic programming"],"prefix":"10.1177","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2780-6659","authenticated-orcid":false,"given":"Xuejie","family":"Wang","sequence":"first","affiliation":[{"name":"School of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, China"},{"name":"School of Electric Power, Shenyang Institute of Engineering, Shenyang, China"}]},{"given":"Yanchao","family":"Ji","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, China"}]},{"given":"Jianze","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering & Automation, Harbin Institute of Technology, Harbin, China"}]},{"given":"Yuanjun","family":"Wang","sequence":"additional","affiliation":[{"name":"Liaoning Electric power Development Group Co., Ltd., Shenyang, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1173-6462","authenticated-orcid":false,"given":"Lei","family":"Qi","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Shenyang University of Technology, Shenyang, China"},{"name":"Liaoning Provincial Institute of Safety Science, Shenyang, China"}]}],"member":"179","published-online":{"date-parts":[[2020,6,27]]},"reference":[{"key":"bibr1-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2014.05.060"},{"key":"bibr2-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/MPE.2008.918702"},{"key":"bibr3-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/MPE.2009.934876"},{"key":"bibr4-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/MPAE.2007.376583"},{"key":"bibr5-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2013.2248400"},{"key":"bibr6-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2015.2427371"},{"key":"bibr7-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2012.09.023"},{"key":"bibr8-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/TPDS.2014.2316155"},{"key":"bibr10-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2013.2282823"},{"key":"bibr11-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1049\/iet-rpg.2010.0052"},{"key":"bibr12-1550147720937141","first-page":"1","volume-title":"Proceedings of the IEEE PES power system conference and exposition","author":"Sortomme E"},{"issue":"3","key":"bibr13-1550147720937141","first-page":"2180","volume":"9","author":"Sandgani MR","year":"2016","journal-title":"IEEE T Smart Grid"},{"key":"bibr14-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/MCOM.2018.1800089"},{"key":"bibr15-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.2964707"},{"key":"bibr16-1550147720937141","doi-asserted-by":"publisher","DOI":"10.1186\/s41601-017-0040-6"}],"container-title":["International Journal of Distributed Sensor Networks"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1550147720937141","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/1550147720937141","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/1550147720937141","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T08:40:05Z","timestamp":1593247205000},"score":1,"resource":{"primary":{"URL":"http:\/\/journals.sagepub.com\/doi\/10.1177\/1550147720937141"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":15,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["10.1177\/1550147720937141"],"URL":"https:\/\/doi.org\/10.1177\/1550147720937141","relation":{},"ISSN":["1550-1477","1550-1477"],"issn-type":[{"value":"1550-1477","type":"print"},{"value":"1550-1477","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6]]}}}