{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:58:49Z","timestamp":1793199529235,"version":"4.5.0"},"reference-count":11,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2024,3,5]],"date-time":"2024-03-05T00:00:00Z","timestamp":1709596800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"funder":[{"name":"Major Research and Development Program of Ningxia Hui Autonomous Region","award":["2022BEG02038"],"award-info":[{"award-number":["2022BEG02038"]}]}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Surg Innov"],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Although the technique of single-incision laparoscopic cholecystectomy (SILC) has improved remarkably, problems such as limited exposure and instrument collision persist. We describe a new SILC technique that uses a set of specially-designed needle instruments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Fifty-six patients with benign gallbladder disease underwent SILC using the newly-designed needle assembly instruments (NAIs). The NAIs comprise an needle assembly exposing hook for operative field exposure and an needle assembly electrocoagulation hook for dissection. During the operation, the NAIs were assembled and disassembled before and after gallbladder removal within the abdominal cavity. The operative efficacy and postoperative complications of this procedure were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>SILC was completed successfully in 52 cases, and four cases (7.14%) required an additional trocar. There were no conversions to open surgery. The mean operative time was 48.2 \u00b1 21.8\u00a0min, and the mean operative bleeding volume was 10.5 \u00b1 12.5\u00a0mL. Minor postoperative complications occurred in 3 cases, including 2 cases of localized fluid accumulation in the abdominal cavity and 1 case of pulmonary infection, and all of them recovered after conservative treatment. There was no occurrence of bile leak, abdominal bleeding, bile duct injury and incisional hernia. The medical cost of each case was saved by approximately $200. The abdominal scars produced by the needle instruments were negligible.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>NAIs can make SILC safer, more convenient, and less expensive.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15533506241237141","type":"journal-article","created":{"date-parts":[[2024,3,5]],"date-time":"2024-03-05T23:57:03Z","timestamp":1709683023000},"page":"286-290","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["Single-Incision Laparoscopic Cholecystectomy Using a Set of Novel Needle Instruments"],"prefix":"10.1177","volume":"31","author":[{"given":"Zhengmin","family":"Cui","sequence":"first","affiliation":[{"name":"Department of Hepatobiliary Surgery, The People\u2019s Hospital of Ning Xia Hui Autonomous Region, Yinchuan, China"},{"name":"Department of Surgery, Linyi People\u2019s Hospital, Linyi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Duoqiang","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery, The People\u2019s Hospital of Ning Xia Hui Autonomous Region, Yinchuan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-4780-916X","authenticated-orcid":false,"given":"Mingguo","family":"Tian","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery, The People\u2019s Hospital of Ning Xia Hui Autonomous Region, Yinchuan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yafei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery, The People\u2019s Hospital of Ning Xia Hui Autonomous Region, Yinchuan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiuping","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Hepatobiliary Surgery, The People\u2019s Hospital of Ning Xia Hui Autonomous Region, Yinchuan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2024,3,5]]},"reference":[{"key":"bibr1-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800840536"},{"key":"bibr2-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1007\/s00595-014-0908-2"},{"key":"bibr3-15533506241237141","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v16.i2.270"},{"key":"bibr4-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-010-1179-7"},{"key":"bibr5-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-009-0504-5"},{"key":"bibr6-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1177\/1553350611427548"},{"key":"bibr7-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1177\/1553350611401428"},{"key":"bibr8-15533506241237141","first-page":"21","volume":"20","author":"Dapri G","year":"2010","journal-title":"Surg Technol Int"},{"key":"bibr9-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1089\/lap.2010.0435"},{"key":"bibr10-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1089\/lap.2010.0512"},{"key":"bibr11-15533506241237141","doi-asserted-by":"publisher","DOI":"10.1007\/s13304-011-0046-y"}],"container-title":["Surgical Innovation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15533506241237141","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15533506241237141","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15533506241237141","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T07:24:14Z","timestamp":1777706654000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15533506241237141"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,5]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["10.1177\/15533506241237141"],"URL":"https:\/\/doi.org\/10.1177\/15533506241237141","relation":{},"ISSN":["1553-3506","1553-3514"],"issn-type":[{"value":"1553-3506","type":"print"},{"value":"1553-3514","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,5]]}}}