{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T03:52:51Z","timestamp":1794541971378,"version":"4.9.1"},"reference-count":28,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:00:00Z","timestamp":1761609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Lymphatic Research and Biology"],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>\n                      Lymph flow measurements can assist in attaining a better understanding of the lymphatic system\u2019s function and its diseases. However,\n                      <jats:italic toggle=\"yes\">in\u00a0vivo<\/jats:italic>\n                      assessment of lymph flow has been challenging. Transit-time ultrasound technique (TTUT) provides direct quantitative lymph flow values and has been used to successfully measure lymph flow in patients with secondary lymphedema. Currently, no measurements using TTUT in healthy subjects have been reported. The aim of this study is to measure lymph flow in healthy subjects using the TTUT.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and Results:<\/jats:title>\n                    <jats:p>Twenty consecutive patients who had an indication for a free radial forearm flap (FRFF) reconstruction were included in the study. Patients with scars on their arms, a history of extremity lymphedema, metastatic disease, or axillary node dissection were excluded. The Transonic\u00ae Microvascular Flow Probe was used to measure lymph flow during FRFF reconstruction in accordance with the Transonic\u00ae protocol for Quantitative Patency Assessment. The subdermal superficial lymphatic collecting vessels had a mean diameter of 0.40 \u00b1 0.10 mm (range: 0.3\u20130.5 mm) and a mean lymph flow velocity of 0.45 \u00b1 0.48 mL\/min (range: 0.08\u20131.68 mL\/min). Neighboring subdermal veins measured had a mean diameter of 0.48 \u00b1 0.11 mm (range: 0.03\u20130.7 mm) and a mean blood flow velocity of 0.96 \u00b1 1.73 mL\/min (range: 0.07\u20137.40 mL\/min).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The TTUT is a viable method to measure real-time lymph flow velocities in healthy subjects. Future studies with a larger sample size are required to validate the TTUT measurement accuracy and establish clinical correlations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1177\/15578585251392546","type":"journal-article","created":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:31:50Z","timestamp":1761690710000},"page":"13-17","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Measuring Lymph Flow Velocity in Lymphatic Collecting Vessels Using a Transit Time Ultrasound Flowprobe"],"prefix":"10.1177","volume":"24","author":[{"given":"Yasmine M.J.","family":"Jonis","sequence":"first","affiliation":[{"name":"Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands."},{"name":"GROW \u2013 School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seth R.","family":"van der Hel","sequence":"additional","affiliation":[{"name":"Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renee","family":"Mis\u00e8re","sequence":"additional","affiliation":[{"name":"Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9 R.W.J.","family":"van der Hulst","sequence":"additional","affiliation":[{"name":"Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands."},{"name":"GROW \u2013 School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shan S.","family":"Qiu","sequence":"additional","affiliation":[{"name":"Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Center, Maastricht, The Netherlands."},{"name":"GROW \u2013 School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2025,10,28]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.semcdb.2015.01.008"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3390\/biology9120463"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1146\/annurev-fluid-122316-045259"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mvr.2014.07.013"},{"key":"e_1_3_2_6_2","volume-title":"StatPearls","author":"Ozdowski LGV","year":"2023","unstructured":"Ozdowski LGV. Physiology, Lymphatic System. In: StatPearls. StatPearls Publishing: Treasure Island (FL); 2023."},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1098\/rsif.2011.0751"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1113\/JP272088"},{"issue":"1","key":"e_1_3_2_9_2","first-page":"1","article-title":"Capillary fluid exchange: Regulation, functions, and pathology","volume":"2","author":"Scallan J","year":"2010","unstructured":"Scallan J, , Huxley VH, , Korthuis RJ. Capillary fluid exchange: Regulation, functions, and pathology. Morgan & Claypool Life Sciences, 2010: San Rafael (CA); 2010;2(1):1\u201394.","journal-title":"Morgan & Claypool Life Sciences"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1089\/lrb.2021.0090"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.isci.2019.11.005"},{"key":"e_1_3_2_12_2","doi-asserted-by":"crossref","unstructured":"Zhang H Guo C Lin J. Effects of Velocity Profiles on Measuring Accuracy of Transit-Time Ultrasonic Flowmeter. 2019.","DOI":"10.3390\/app9081648"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.06.010"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s007010170133"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjps.2015.07.020"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1089\/lrb.2019.0088"},{"key":"e_1_3_2_17_2","unstructured":"Transonic. Quantitative Patency Assessment. 2014. Available from: https:\/\/www.transonic.com\/resources\/microvascular\/flyers-applications\/protocol-steps-for-successful-flow-measurement-during-creation-of-a-microvascular-anastomosis\/"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-32109-2_36"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/srep29035"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1117\/1.2135791"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1996.270.1.H358"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1172\/jci.insight.96591"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.14814\/phy2.15697"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.2007.130401"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3390\/cancers12082297"},{"key":"e_1_3_2_26_2","doi-asserted-by":"crossref","unstructured":"Drost GGT CJ Sellers AF. In vivo validation of the transit-time ultrasonic volume flow meter. Proceedings of the 7th New England (Northeast) Bioengineering Conference 1979.","DOI":"10.1016\/B978-0-08-024634-5.50062-5"},{"key":"e_1_3_2_27_2","unstructured":"Drost CJ. Vessel diameter-independent flow measurements using ultrasound. Proceedings of the San Diego Biomedical Symposium 1978; 17."},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1093\/cvr\/cvab279"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200409000-00017"}],"container-title":["Lymphatic Research and Biology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15578585251392546","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15578585251392546","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15578585251392546","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T07:27:07Z","timestamp":1777706827000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15578585251392546"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,28]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,2,1]]}},"alternative-id":["10.1177\/15578585251392546"],"URL":"https:\/\/doi.org\/10.1177\/15578585251392546","relation":{},"ISSN":["1539-6851","1557-8585"],"issn-type":[{"value":"1539-6851","type":"print"},{"value":"1557-8585","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,28]]}}}