{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T14:01:42Z","timestamp":1784988102618,"version":"3.55.0"},"reference-count":32,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Dose-Response"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:p>\n                    Accurate dose estimation following radiation accidents remains challenging, particularly when personal dosimeter data are unavailable. This study presents a practical post-accident dose reconstruction approach based on minute-rate thermoluminescent dosimeter (TLD) measurements combined with exposure scenario reconstruction, demonstrated through a wavelength-dispersive X-ray fluorescence (WD\u2012XRF) spectrometer accident. The exposure scenario was reconstructed by placing LiF(Mg,Cu,P) TLDs at seven representative positions corresponding to head and hand locations, with the spectrometer operated under the recorded technical parameters (40 kV, 7 mA). Minute personal dose equivalent rates,\n                    <jats:italic toggle=\"yes\">H<\/jats:italic>\n                    <jats:sub>p<\/jats:sub>\n                    \u2032(10), were measured and combined with reconstructed retention times to calculate cumulative doses, from which skin absorbed doses were derived. The measured dose rates ranged from 0.13 to 358.38 mSv\/min for the head and from 0.07 to 620.24 mSv\/min for the hands. The resulting cumulative skin absorbed doses were 7.58 Gy for the head and 12.52 Gy for the hands, consistent with reported dose ranges associated with localized radiation injury. This approach provides a feasible supplementary strategy for retrospective dose reconstruction under emergency or resource-limited conditions when conventional dosimetric information is unavailable.\n                  <\/jats:p>","DOI":"10.1177\/15593258261471512","type":"journal-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T18:03:39Z","timestamp":1784829819000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Dose Reconstruction After a WD\u2012XRF Spectrometer Accident Using Minute-Rate TLD Measurements"],"prefix":"10.1177","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1061-1326","authenticated-orcid":false,"given":"Yiying","family":"Gao","sequence":"first","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoyu","family":"Wang","sequence":"additional","affiliation":[{"name":"Tianjin Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"He","sequence":"additional","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liangguo","family":"He","sequence":"additional","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wantian","family":"Wang","sequence":"additional","affiliation":[{"name":"North Sichuan Medical College"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linyu","family":"Li","sequence":"additional","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yurou","family":"Zhang","sequence":"additional","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxing","family":"Xue","sequence":"additional","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuyu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Sichuan University"},{"name":"Southwest University of Science and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deming","family":"Liu","sequence":"additional","affiliation":[{"name":"Sichuan Center for Disease Control and Prevention"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"key":"e_1_3_5_2_2","doi-asserted-by":"publisher","DOI":"10.5829\/idosi.wasj.2013.21.2.2421"},{"key":"e_1_3_5_3_2","volume-title":"The Radiological Accident in Ventanilla","author":"International Atomic Energy Agency","year":"2014","unstructured":"International Atomic Energy Agency. The Radiological Accident in Ventanilla. International Atomic Energy Agency; 2014."},{"key":"e_1_3_5_4_2","volume-title":"The Radiological Accident in Yanango, Peru","author":"International Atomic Energy Agency","year":"1999","unstructured":"International Atomic Energy Agency. The Radiological Accident in Yanango, Peru. International Atomic Energy Agency; 1999."},{"key":"e_1_3_5_5_2","doi-asserted-by":"publisher","DOI":"10.1590\/1414-431X20144337"},{"key":"e_1_3_5_6_2","volume-title":"Cytogenetic Analysis for Radiation Dose Assessment: A Manual","author":"International Atomic Energy Agency","year":"2001","unstructured":"International Atomic Energy Agency. Cytogenetic Analysis for Radiation Dose Assessment: A Manual. International Atomic Energy Agency; 2001. Technical Reports Series No. 405."},{"key":"e_1_3_5_7_2","volume-title":"Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies EPR-Biodosimetry 2011","author":"International Atomic Energy Agency","year":"2011","unstructured":"International Atomic Energy Agency. Cytogenetic Dosimetry: Applications in Preparedness for and Response to Radiation Emergencies EPR-Biodosimetry 2011. International Atomic Energy Agency; 2011."},{"key":"e_1_3_5_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/nct032"},{"key":"e_1_3_5_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals\/rpd\/a033288"},{"key":"e_1_3_5_10_2","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/abc181"},{"key":"e_1_3_5_11_2","volume-title":"Proceedings of the 12th International Congress of the International Radiation Protection Association","author":"Huet C","year":"2008","unstructured":"Huet C, Trompier F, Clairand I, et al. Physical dose reconstruction in case of radiological ccidents: an asset for the victims ' management. In: Proceedings of the 12th International Congress of the International Radiation Protection Association. Buenos Aires, Argentina; 2008."},{"key":"e_1_3_5_12_2","doi-asserted-by":"publisher","DOI":"10.1080\/09553002.2016.1178866"},{"key":"e_1_3_5_13_2","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncs157"},{"key":"e_1_3_5_14_2","volume-title":"Diagnosis and Treatment of Radiation Injuries","author":"International Atomic Energy Agency","year":"1998","unstructured":"International Atomic Energy Agency. Diagnosis and Treatment of Radiation Injuries. International Atomic Energy Agency; 1998."},{"key":"e_1_3_5_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/jrr\/rrz072"},{"key":"e_1_3_5_16_2","doi-asserted-by":"publisher","DOI":"10.1667\/rade-24-00261.1"},{"key":"e_1_3_5_17_2","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/ac241a"},{"key":"e_1_3_5_18_2","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/ad35ce"},{"key":"e_1_3_5_19_2","doi-asserted-by":"publisher","DOI":"10.4103\/jmp.jmp_51_22"},{"key":"e_1_3_5_20_2","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncab045"},{"key":"e_1_3_5_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.12.016"},{"key":"e_1_3_5_22_2","volume-title":"Radiation Protection Requirements for Personal Dosimetry","author":"GBZ\/T 244-2017","year":"2017","unstructured":"GBZ\/T 244-2017. Radiation Protection Requirements for Personal Dosimetry. Beijing: China National Health Commission; 2017."},{"key":"e_1_3_5_23_2","doi-asserted-by":"publisher","DOI":"10.1017\/dmp.2021.348"},{"key":"e_1_3_5_24_2","doi-asserted-by":"publisher","DOI":"10.3389\/fpubh.2025.1547818"},{"key":"e_1_3_5_25_2","doi-asserted-by":"publisher","DOI":"10.3389\/fpubh.2024.1410722"},{"key":"e_1_3_5_26_2","doi-asserted-by":"publisher","DOI":"10.1093\/ced\/llae547"},{"key":"e_1_3_5_27_2","doi-asserted-by":"publisher","DOI":"10.3389\/fpubh.2021.657564"},{"key":"e_1_3_5_28_2","volume-title":"Classification of Radiation Apparatus","author":"MEE Order No. 66","year":"2017","unstructured":"MEE Order No. 66. Classification of Radiation Apparatus; 2017."},{"key":"e_1_3_5_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/bjh.16138"},{"key":"e_1_3_5_30_2","doi-asserted-by":"publisher","DOI":"10.1093\/jrr\/rraa113"},{"key":"e_1_3_5_31_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2021-052670"},{"key":"e_1_3_5_32_2","doi-asserted-by":"publisher","DOI":"10.1093\/jrr\/rrab064"},{"key":"e_1_3_5_33_2","doi-asserted-by":"publisher","DOI":"10.1093\/jrr\/rrab052"}],"container-title":["Dose-Response"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15593258261471512","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1177\/15593258261471512","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1177\/15593258261471512","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T13:18:16Z","timestamp":1784985496000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1177\/15593258261471512"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1177\/15593258261471512"],"URL":"https:\/\/doi.org\/10.1177\/15593258261471512","relation":{},"ISSN":["1559-3258","1559-3258"],"issn-type":[{"value":"1559-3258","type":"print"},{"value":"1559-3258","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"article-number":"15593258261471512"}}